Perturbation Effect of Fiducial Marker on 3D Dose Distribution in External Surrogates Radiotherapy

被引:0
|
作者
Torshabi A.E. [1 ]
Taghipour M. [1 ]
机构
[1] Faculty of Sciences and Modern Technologies, Graduate University of Advanced Technology, Kerman
来源
Iranian Journal of Medical Physics | 2021年 / 18卷 / 02期
关键词
Radiotherapy Fiducial Marker Radiation Dosage Monte Carlo method;
D O I
10.22038/ijmp.2020.44330.1677
中图分类号
学科分类号
摘要
Introduction: Tumor motion is a challenging issue in radiotherapy, which complicates the process of tumor delineation, localization, and dose delivery. External surrogate radiotherapy is one of the available strategies that provides motion dataset for a consistent prediction model to track tumor motion using internal-external markers. Regarding this, the present study was conducted to investigate the effect of implanted fiducial on 3D uniform dose distribution. Material and Methods: For the purpose of the study, a Monte Carlo code was utilized to simulate clip with different dimensions and material structures against four therapeutic beams. Moreover, a combinational clip made of golden and covered by polymethyl methacrylate (PMMA) was proposed to be used with lower dose perturbation. Finally, it was proposed to implant a clip outside tumor volume at specific distances from tumor site to keep dose uniformity on tumor volume. To investigate this issue, the correlation coefficient parameter was calculated as the metric among the motion dataset of tumor and clip. Results: Based on the results, dose perturbation caused by implanted clip was remarkable at hadron therapy depending on its size and material, mainly at the downstream part of the clip. Conclusion: As the findings indicated, the golden marker covered with PMMA could remarkably reduce dose perturbation. The most important concern in this domain is the presence of a possible correlation between tumor motion and motion of the clip implanted outside the tumor volume. The results of the correlation coefficient revealed a close relationship between tumor motion and clip motion. © 2021. All Rights Reserved.
引用
收藏
页码:96 / 105
页数:9
相关论文
共 50 条
  • [1] Depth dose perturbation by a hydrogel fiducial marker in a proton beam
    Zhang, Miao
    Reyhan, Meral
    Kim, Leonard H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 373 - 376
  • [2] The effect of magnetic port density on dose distribution in 3D, IMRT, VMAT for breast radiotherapy
    Rygielska, A.
    Walewska, A.
    Gabor, M.
    Pruska-Pich, D.
    Czeremszynska, B.
    Kepka, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S794 - S794
  • [3] 3D Model Visualization and Interaction Using a Cubic Fiducial Marker
    Rabbi, Ihsan
    Ullah, Sehat
    AUGMENTED AND VIRTUAL REALITY, AVR 2014, 2014, 8853 : 381 - 393
  • [4] Predicting 3D dose distribution with scale attention network for prostate radiotherapy
    Adabi, Saba
    Tzeng, Tzu-Chi
    Yuan, Yading
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [5] Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery
    Speidel, Michael A.
    Wilfley, Brian P.
    Hsu, Annie
    Hristov, Dimitre
    MEDICAL PHYSICS, 2012, 39 (04) : 2163 - 2169
  • [6] EXOMIO: A 3D simulator for external beam radiotherapy
    Karangelis, G
    Zamboglou, N
    Baltas, D
    Sakas, G
    VOLUME GRAPHICS 2001, 2001, : 351 - +
  • [7] A Feasibility Study for Predicting 3D Radiotherapy Dose Distribution of Lung VMAT Patients
    Liu, Runxin
    Bai, Jingfeng
    Zhou, Jingjie
    Zhang, Kang
    Ni, Cheng
    2020 IEEE 32ND INTERNATIONAL CONFERENCE ON TOOLS WITH ARTIFICIAL INTELLIGENCE (ICTAI), 2020, : 1304 - 1308
  • [8] Automated Fiducial-Based Registration and Dose Normalization for 3D Dosimetry
    Wang, Y.
    Dona, O.
    Xu, Y.
    Adamovics, J.
    Wuu, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E116 - E116
  • [9] EVALUATION OF THE EXTRA DOSE IN EXTERNAL BEAM 3D CONFORMAL RADIOTHERAPY AS THE RESULT OF ADDITIONAL PORTAL IMAGING
    Ventosa, N.
    Rial, E.
    Soria, M. A.
    Torres, M.
    Bermejo, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S579 - S580
  • [10] External Validation of 3D Spatial Dose-Response Mapping for Toxicity Subsequent to Pelvic Radiotherapy
    Marcello, M.
    Kennedy, A.
    Haworth, A.
    Holloway, L.
    Dowling, J.
    Greer, P.
    Gulliford, S.
    Dearnaley, D.
    Sydes, M.
    Hall, E.
    Denham, J.
    Ebert, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E314 - E314