Sequence Impedance Modeling and Analysis of Cascaded H-Bridge Static Var Generator Based on Double-Harmonic Linearization

被引:0
|
作者
Zhang Y. [1 ]
Shen M. [1 ]
Chen X. [1 ]
Chen J. [1 ]
Gong C. [1 ]
机构
[1] Jiangsu Key Laboratory of New Energy Generation and Power Conversion, Nanjing University of Aeronautics & Astronautic, Nanjing
关键词
Cascaded H-bridge; Double-harmonic linearization; Module multilevel converter (MMC); Sequence impedance modeling; Static var generator;
D O I
10.19595/j.cnki.1000-6753.tces.181154
中图分类号
学科分类号
摘要
Electrical resonance with the grid is an increasingly common problem for wind farms involving cascaded H-bridge static var generator (SVG) in a regional large-scale renewable energy system. To analyze and solve such resonance problems, it is necessary to fully understand the frequency-domain behavior of cascaded H-bridge SVG. Because the existing harmonic linearization method has complicated linearization process and ignores the harmonic influence when establishing the module multilevel converter (MMC) model, a double-harmonic linearization method, which only considers the effects of the fundamental and second harmonics, was proposed to develop the sequence impedance model of cascaded H-bridge SVG. This method considers the harmonic effects of each variables in power and control circuits, and introduces a matrix formulation to simplify the linearization process and sequence impedance models. In addition, to improve the accuracy of models, the effects of overall module capacitor voltage control were considered in small-signal modeling. The developed sequence impedance models were verified by the specific converter circuit simulation and the experiment based on a scaled-down prototype. The influencing factors of frequency coupling and the design of sub-module capacitor were analyzed and discussed. © 2019, Electrical Technology Press Co. Ltd. All right reserved.
引用
收藏
页码:4334 / 4346
页数:12
相关论文
共 22 条
  • [1] Chen X., Zhang Y., Wang Y., A study of dynamic interaction between PV grid-connected inverters and the grid based on the impedance analysis method, Proceedings of the CSEE, 34, 27, pp. 4559-4567, (2014)
  • [2] Xie X., Liu H., He J., Et al., Mechanism and characteristics of subsynchronous oscillation caused by the interaction between full-converter wind turbines and AC systems, Proceedings of the CSEE, 36, 9, pp. 2366-2372, (2016)
  • [3] Sun J., Li M., Zhang Z., Et al., Rene-wable energy transmission by HVDC across the continent: system challenges and opportunities, CSEE Journal of Power & Energy Systems, 3, 4, pp. 353-364, (2017)
  • [4] Ren B., Du W., Wang H., Analysis on sub-synchronous control interaction between static synchronous compensator and permanent magnet synchronous generator, Transactions of China Electrotechnical Society, 33, 24, pp. 5884-5896, (2018)
  • [5] Sun J., Impedance-based stability criterion for grid-connected inverters, IEEE Transactions on Power Electronics, 26, 11, pp. 3075-3078, (2011)
  • [6] Zhang Y., Chen X., Wang Y., Et al., Impedance-phased dynamic control method of grid-connected inverters under weak grid condition, Transactions of China Electrotechnical Society, 32, 1, pp. 97-106, (2017)
  • [7] Vieto I., Sun J., Damping of subsynchronous resonance involving type-III wind turbines, IEEE Control and Modeling for Power Electronics, pp. 1-8, (2015)
  • [8] Cespedes M., Sun J., Impedance modeling and analysis of grid-connected voltage-source con-verters, IEEE Transactions on Power Electronics, 29, 3, pp. 1254-1261, (2013)
  • [9] Liu H., Sun J., Voltage stability and control of offshore wind farms with AC collection and HVDC transmission, IEEE Journal of Emerging & Selected Topics in Power Electronics, 2, 4, pp. 1181-1189, (2014)
  • [10] Lu J., Cai X., Harmonic linearization based impedance modeling of modular multilevel con-verters, Automation of Electric Power System, 41, 4, pp. 136-142, (2017)