Z-SOURCE PHOTOVOLTAIC GRID-CONNECTED INVERTER WITH COMMON-MODE LEAKAGE CURRENT INHIBITION

被引:0
|
作者
Dai Y. [1 ,2 ]
Tang H. [1 ]
Liu M. [1 ]
Chen Y. [1 ]
Yan C. [1 ]
Yang X. [1 ]
机构
[1] Intelligent Manufacturing Institute, Yibin Vocational and Technical College, Yibin
[2] School of Aeronautics and Astronautics, University of Electronic Science and Technology of China, Chengdu
来源
关键词
grid connected; inverters; leakage current; photovoltaic power; Z-source;
D O I
10.19912/j.0254-0096.tynxb.2022-1776
中图分类号
学科分类号
摘要
The quasi-Z-source H-bridge grid-connected inverter(GCI)is well known as its no shoot-through problem and high efficiency of DC voltage,but the common-mode leakage current exists in the power frequency cycle. To solve the problems of quasi-Z-source H-bridge GCI,a new Z-Source photovoltaic grid-connected inverter(ZPGCI)with coupled cnductor coil topology is proposed. Also,a unipolar sinusoidal pulse width modulation (USPWM) strategy that can make the common- mode voltage constant is presented. Secondly,operating modes,common- mode leakage current and direct operating mode analysis shows that ZPGCI not only has the advantages of no shoot-through problem and high reliability,but also can eliminate the high-frequency common-mode leakage current of quasi- Z- source H- bridge GCI. At last,the correctness of the novel ZPGCI topology and theoretical analysis are verified by the comparison experiment of traditional quasi-Z-source H-bridge GCI and new ZPGCI circuit. © 2024 Science Press. All rights reserved.
引用
收藏
页码:517 / 522
页数:5
相关论文
共 12 条
  • [1] GUO X Q, YANG Y, WANG B C., Leakage Current reduction of three- phase Z- source three- level four- leg inverter for transformerless PV system[J], Acta energiae solaris sinica, 41, 2, pp. 325-332, (2020)
  • [2] Research on transformerless dual-buck full-bridge grid-connected inverter with H5-type for PV systems[J], IET power electronics, 12, 1, pp. 44-50, (2019)
  • [3] HONG F, WAN Y Q,, ZHAO X, Et al., A novel interleaved dual-buck full-bridge three-level photovoltaic grid inverter [J], Proceedings of the CSEE, 34, 21, pp. 3397-3404, (2014)
  • [4] MARDANEH M., Improved symmetric switched- inductor/capacitor quasi Z- source inverter with ability uplifted-Boost [J], International journal of industrial electronics,control and optimization, 3, 1, pp. 45-58, (2020)
  • [5] MASSOUD A M,, Et al., A pulsewidth modulation technique for high- voltage gain operation of three- phase Z- source inverters[J], IEEE journal of emerging and selected topics in power electronics, 4, 2, pp. 521-533, (2016)
  • [6] LI H Z, LIU F Y,, LIU Y,, Et al., A new magnetically integrated high gain coupled inductance voltage- doubled Boost converter[J], Transactions of China Electrotechnical Society, 35, S2, pp. 450-460, (2020)
  • [7] LIANG W H, Et al., Night operation,analysis, and control of single- phase quasi- Z- source photovoltaic power system[J], IET renewable power generation, 13, 15, pp. 2817-2829, (2019)
  • [8] Automatic disconnection device between a generator and the public low-voltage grid
  • [9] RONG D S, WANG N, SUN X J., A zero- ripple output-current high-gain Boost converter with coupled inductance [J], Acta energiae solaris sinica, 43, 4, pp. 129-136, (2022)
  • [10] JI B J, WANG J H, ZHAO J F., A high efficiency non-isolated single-phase photovoltaic grid-connected inverter with H6-type configuration[J], Proceedings of the CSEE, 32, 18, pp. 9-15, (2012)