ANALYSIS OF COMPOUND FAULT CHARACTERISTICS OF WIND TURBINES STATOR WINDING INTER-TURN SHORT CIRCUIT AND BLADE IMBALANCE BASED ON SPATIOTEMPORAL DISTRIBUTION OF WIND SPEED

被引:0
|
作者
Wang X. [1 ]
Wan S. [1 ]
Sheng X. [1 ]
机构
[1] North China Electric Power University, Hebei Key Laboratory of Electric Machinery Health Maintenance & Failure Prevention, Baoding
来源
关键词
blade imbalance; doubly-fed wind turbines; fault diagnosis; stator winding inter-turn short circuit; wind speed; wind turbines;
D O I
10.19912/j.0254-0096.tynxb.2022-0481
中图分类号
学科分类号
摘要
Considering the spatiotemporal distribution of wind speed caused by wind shear and tower shadow,the influence of the compound fault of the stator winding inter-turn short-circuit,and the blade imbalance on the electrical characteristics of the doubly-fed induction generator is studied. Firstly,the analytical expression and variation characteristics of rotor current under blade imbalance fault,stator winding inter-turn short-circuit,and compound fault are deduced. Then,the fault simulation model of the doubly-fed induction generator is built on the Matlab/Simulink platform. The experimental test and research are carried out on the doubly-fed induction generator fault simulation platform,which can simulate the equivalent wind speed and rotational speed characteristics. The theoretical derivation,simulation analysis,and experimental research results show that,after considering the spatiotemporal distribution of wind speed,the rotor current contains a modulation frequency of 3kP(P is the rotational frequency of the blade)when the stator winding inter-turn short-circuit fault occurs. When the blade imbalance,the rotor current has P,3kP and its coupling modulation frequency(3k ± 1)P. The rotor current has modulation frequencies P,3kP and(3k ± 1)P around(2 ± s)f and fundamental frequency when compound fault. This paper uses the equivalent wind speed to replace the average wind speed. This research is more in line with the actual operating conditions of doubly-fed induction generator in nature and can provide a reference for fault diagnosis in the actual operation of doubly-fed induction generator. © 2023 Science Press. All rights reserved.
引用
收藏
页码:318 / 327
页数:9
相关论文
共 14 条
  • [1] LI Y G, LI H M, WAN S T., Analysis and identification of generator rotor winding inter- turn short circuit fault characteristics, (2009)
  • [2] CHENG J, SONG S P,, Et al., Stator inter-turn fault analysis in doubly- fed induction generators using rotor current based on finite element analysis, 2018 IEEE International Conference on Progress in Informatics and Computing, pp. 414-419, (2018)
  • [3] XU B Q, ZHANG S Y., Modeling and stability analysis of DFIG with stator fault[J], Electric power automation equipment, 36, 9, pp. 93-99, (2016)
  • [4] CHEN Z, Et al., Diagnosis of inter-turn faults in stator windings of asynchronous motor[J], Electric machines & control application, 46, 5, pp. 120-125, (2019)
  • [5] CHEN Y, ZHAO Y H,, Et al., Numerical modeling, electrical characteristics analysis and experimental validation of severe inter- turn short circuit fault conditions on stator winding in DFIG of wind turbines [J], IEEE access, 9, pp. 13149-13158, (2021)
  • [6] WANG D Y,, GU H G,, WEI S R,, Et al., Diagnosis of inter-turn short-circuit fault in stator windings of DFIG based on mechanical and electrical signal fusion[J], Automation of electric power systems, 44, 9, pp. 171-178, (2020)
  • [7] Aerodynamic analysis of a wind- turbine rotor affected by pitch unbalance[J], Energies, 14, 3, (2021)
  • [8] YANG T,, REN Y,, LIU X,, Et al., Research on the modeling and simulation of wind turbine rotor imbalance fault[J], Journal of mechanical engineering, 48, 6, pp. 130-135, (2012)
  • [9] XING Z,, CHEN M,, LIU Y,, Et al., Study on the characteristic analysis and fault diagnosis strategy of rotor imbalance of wind turbine, Online Conference:The 10th Renewable Power Generation Conference(RPG 2021, pp. 482-488, (2021)
  • [10] LEHN P W., Simulation model of wind turbine 3p torque oscillations due to wind shear and tower shadow[J], IEEE transactions on energy conversion, 21, 3, pp. 717-724, (2006)