Functional Lightweight Aggregates in Mass Concrete:Application and Temperature Control Technology

被引:0
|
作者
Pang C. [1 ,2 ]
Liu Z. [3 ]
Mao Y. [1 ,2 ]
Zhang C. [1 ,2 ]
机构
[1] School of Materials Science and Engineering, Southeast University, Nanjing
[2] Jiangsu Key Laboratory of Civil Engineering Material, Southeast University, Nanjing
[3] Road&Bridge International Co.,Ltd., Beijing
关键词
hydration process; mass concrete; temperature control; thermal insulation lightweight aggregate; thermal storage phase⁃change lightweight aggregate;
D O I
10.3969/j.issn.1007-9629.2023.08.005
中图分类号
学科分类号
摘要
Application techniques of two functional light aggregates(thermal insulation fine aggregate and thermal storage coarse aggregate)in C55 and C30 mass concrete and their effects on the hydration process of cement were investigated. The influence of functional light aggregate admixture on the fresh concrete properties,mechanical properties,peak temperature,and rate of temperature rise was measured. An application technique under semi⁃saturated conditions and controled comparable working performance by decreasing water content was proposed. The results indicate that both thermal insulation fine aggregate and thermal storage coarse aggregate have certain early strength and temperature control functions,in which the thermal storage coarse aggregate is better. The thermal insulation fine aggregate has little effect on the setting and hardening rate of concrete,whereas the thermal storage coarse aggregate can play the role of in⁃situ self⁃heating curing in the early stage due to its phase change energy storage,which obviously speeds up the setting and hardening rate. © 2023 Tongji University. All rights reserved.
引用
收藏
页码:853 / 861
页数:8
相关论文
共 27 条
  • [1] WANG Han, Research on control of construction crack of mass concrete raft⁃foundation[D], (2013)
  • [2] BIAN Zhen, Study of dynamic analysis and control on temperature stress of mass concrete[D], (2012)
  • [3] XU Jun, Research on mass concrete temperature field,stress field and the temperature control measures[D], (2014)
  • [4] WANG Yuping, DONG Xiangsheng, HAO Bailong, Et al., Measures for controlling cracks of No. 5 base slab of Badong Yangtze River Bridge[J], Technology of Highway Transport, 5, (2004)
  • [5] GOU Ji, Study on the effect of mass concrete hydration heat on structure[D], (2008)
  • [6] ZHANG Dong, ZHOU Jianmin, WU Keru, Et al., Study on fabrication method and energy storing behavior of phase changing energy storing concrete[J], Journal of Building Materials, 6, 4, (2003)
  • [7] PASUPATHY A, ATHANASIUS L, VELRAJ R, Et al., Experimental investigation and numerical simulation analysis on the thermal performance of a building roof incorporating phase change material(PCM) for thermal management[J], Applied Thermal Engineering, 28, (2008)
  • [8] GAO Guibo, QIAN Chunxiang, ZHUANG Yuan, Et al., Research on use of phase change materials for reducrion of internal temperature rise of mass concrete[J], Journal of Hydroelectric Engineering, 29, 1, (2010)
  • [9] XIN Juanjuan, GUAN Xiaojun, Study on the control over the cement hydration heat of the phase change materials[J], Research and Application of Building Materials, 6, (2006)
  • [10] FENG Qian, LIU Xianjie, PENG Zhigang, Et al., Preparation and application of microcapsule type thermal control material for low hydration heat cement slurry[J], Fine Chemicals, 36, 7, (2019)