Research on transient-based relay protection

被引:0
|
作者
Zheng B. [1 ]
Wang Z. [1 ]
Lü Z. [2 ]
Wang T. [1 ]
机构
[1] State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing
[2] Department of Electrical Engineering, Tsinghua University, Beijing
基金
中国国家自然科学基金;
关键词
AC-DC hybrid system; Power-frequency protection; Transient response;
D O I
10.19783/j.cnki.pspc.202083
中图分类号
学科分类号
摘要
Wide application of power electronic equipment has made the fault transient process of a power system more complicated and faster. This forces higher requirements on the "four characteristics" of relay protection. Therefore, the advantages of transient-based relay protection have become more prominent. First, the fault characteristics of the electronic power system are introduced. The fast adjustment and fragility of power electronic devices and their influence on the fault characteristics of a power system are analyzed in detail. Secondly, the application of transient quantities in line protection is comprehensively established, including traveling wave front protection, single-ended transient protection, etc. Then, new principles and methods of protection based on double-ended (multi-terminal) transients are analyzed. Finally, suggestions for research on transient-based protection are given. By rationally using the abundant transient information in the entire fault process, high-speed transient-based protection which could adaptively be matched to the fault is realized, and the "first line of defense" for power grid security can be fully established. © 2020, Power System Protection and Control Press. All right reserved.
引用
收藏
页码:18 / 25
页数:7
相关论文
共 28 条
  • [1] WANG Zengping, JIANG Xianguo, ZHANG Zhichao, Et al., Relay protection for smart grid, Power System Protection and Control, 26, 2, pp. 13-18, (2013)
  • [2] DONG Xinzhou, GE Yaozhong, XU Bingyin, Research of fault location based on current travelling waves, Proceedings of the CSEE, 19, 4, pp. 76-80, (1999)
  • [3] ZHANG Baohui, KONG Fei, ZHANG Song, Et al., Technical development of non-unit protection devices based on transient signals for HVDC transmission lines, Proceedings of the CSEE, 33, 4, pp. 179-185, (2013)
  • [4] ZHANG Baohui, ZHANG Song, YOU Min, Et al., Research on transient-based protection for HVDC lines, Power System Protection and Control, 38, 15, pp. 18-23, (2010)
  • [5] HOU Junjie, SONG Guobing, CHANG Zhongxue, Et al., Transient power based single-end protection for HVDC transmission lines, Automation of Electric Power System, 43, 21, pp. 203-216, (2019)
  • [6] CHEN Guoping, WANG Delin, QIU Yutao, Et al., Challenges and development prospects of relay protection technology, Automation of Electric Power Systems, 41, 16, pp. 1-11, (2017)
  • [7] ALBASRI F A, SIDHU T S, VARMA R K., Performance comparison of distance protection schemes for shunt-FACTS compensated transmission lines, IEEE Transactions on Power Delivery, 22, 4, pp. 2116-2125, (2007)
  • [8] KONG Xiangping, YUAN Yubo, GAO Lei, Et al., Study of distance protection scheme for transmission line including UPFC, Proceedings of the CSEE, 36, 19, pp. 5219-5226, (2016)
  • [9] LU Zhe, WANG Zengping, XU Wanyu, Et al., Pilot protection of UPFC line based on transient spectrum information of busbar-connected outgoing lines, Automation of Electric Power Systems, 44, 2, pp. 139-152, (2020)
  • [10] SUONAN Jiale, ZHANG Jiankang, JIAO Zaibin, Et al., AC fault characteristic analysis of AC-DC hybrid transmission grid, High Voltage Engineering, 36, 6, pp. 1461-1467, (2010)