Rupture of an Intramedullary Elastic Bundle Nail following Humeral shaft Nonunion: A case report

被引:0
|
作者
Corradi N. [1 ]
Caruso G. [2 ]
Martini I. [1 ]
Massari L. [2 ]
机构
[1] Department of Morphology, Experimental Medicine and Surgery, Azienda Ospedaliero-Univeristaria di Ferrara–Arcispedale Sant’Anna, University of Ferrara
[2] Department of Biomedical and Specialty Surgical Sciences, Azienda Ospedaliero-Universitaria di Ferrara–Arcispedale Sant’Anna, University of Ferrara
来源
关键词
Bundle nail; Humeral shaft fracture; Intramedullary nailing; Nails rupture; Nonunion;
D O I
10.1615/JLongTermEffMedImplants.2019030530
中图分类号
学科分类号
摘要
A 77-year-old woman reported a spiral right humeral shaft fracture, which was treated by closed reduction and fixation with elastic bundle retrograde intramedullary nail. Despite a proper closed reduction and a minimally invasive surgery obtained, nonunion arose. The patient refused the advised second surgical treatment. At 12 months, the patient was admitted to our department as a consequence of persistent pain and unnatural humeral shaft mobility. New X-ray imaging highlighted intramedullary nail rupture due to excessive implant mobility at the nonunion site. Consequently, nail removal was performed, and plate and screws were then fixed, and a bone allograft was placed to allow fracture healing and proper stabilization. The literature reports optimal outcomes with elastic bundle intramedullary nailing. It is strongly suggested to obtain a closed reduction and minimally invasive dynamic fixation. Nonetheless, it may lead to several complications such as nonunion, for which surgical treatment is technically demanding and highly invasive. © 2019 by Begell House, Inc.
引用
收藏
页码:11 / 17
页数:6
相关论文
共 50 条
  • [1] Nonunion of the Humeral Shaft Treated by Intramedullary Impaction. A Case Report
    Sanchez Perez, Yosvani
    Padilla de la Cruz, Ramon
    de la Caridad Rodriguez de la Rosa, Graciela
    Cabrera Reyes, Yamisel
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2014, 12 (03): : 522 - 527
  • [2] Humeral intramedullary nail bending following trauma: a case report
    Willems, Siem A.
    Greeven, Alexander P. A.
    JOURNAL OF TRAUMA AND INJURY, 2023, 36 (01): : 65 - 69
  • [3] Humeral nonunion associated with metallosis secondary to use of a titanium flexible humeral intramedullary nail - A case report
    Kang, R
    Stern, PJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12): : 2266 - 2269
  • [4] Pediatric Humeral Shaft Fracture Nonunion: A Case Report
    Lipphardt, Matthew
    Zamzam, Mazen
    Saleh, Ehab S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
  • [5] Nonunion after intramedullary nailing of humeral shaft fracture
    Flinkkilä, T
    Ristiniemi, J
    Hämäläinen, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (03): : 540 - 544
  • [6] Treatment of humeral shaft fractures with the seidel intramedullary nail
    Bain, GI
    Sandow, MJ
    Howie, DW
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (03): : 156 - 158
  • [7] Treatment of humeral shaft fractures with antegrade intramedullary locking nail
    Tsourvakas S.
    Alexandropoulos C.
    Papachristos I.
    Tsakoumis G.
    Ameridis N.
    MUSCULOSKELETAL SURGERY, 2011, 95 (3) : 193 - 198
  • [8] Intramedullary Nail Fixation for the Treatment of Pathologic Humeral Shaft Fractures
    Colello, Michael J.
    Hunter, Michael D.
    Tanner, Stephanie L.
    Porter, Scott E.
    ORTHOPEDICS, 2020, 43 (05) : E389 - E398
  • [9] Humeral shaft fractures Intramedullary nail versus plate fixation
    Mohid Bhandari
    Joseph R
    Beate P.Hanson
    Dan C. Norvell
    中华创伤骨科杂志, 2004, (06) : 81 - 83
  • [10] Intramedullary nailing of humeral shaft fractures with a locking flexible nail
    Stannard, JP
    Harris, HW
    McGwin, G
    Volgas, DA
    Alonso, JE
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11): : 2103 - 2110