Vibration Fault Diagnosis and Treatment of Vertical Long Shaft Pump Motor in Nuclear Power Plants

被引:0
|
作者
Fu J. [1 ]
Wei W. [1 ]
Liu M. [1 ]
Wang Y. [1 ]
机构
[1] Shandong Nuclear Power Plant, Yantai, 265116, Shandong
来源
关键词
Dynamic balance; Spectrum analysis; Structure resonance; Thermal bend; Vertical pump;
D O I
10.13832/j.jnpe.2020.03.0217
中图分类号
学科分类号
摘要
In a nuclear power plant, the vertical pump motor has a large vibration difference between the two radial directions, and the vibration phenomenon slowly rises after the start. To solve the vibration problem, this paper uses methods such as spectrum analysis, natural frequency analysis, and phase analysis to diagnose the fault. It is found that the matching motor is with the coupling problem of structural resonance, rotor thermal bending and dynamic unbalance, and the vibration problem is solved by adjusting the bolt and the on-site dynamic balance method. © 2020, Editorial Board of Journal of Nuclear Power Engineering. All right reserved.
引用
收藏
页码:217 / 220
页数:3
相关论文
共 4 条
  • [1] 1, pp. 46-50
  • [2] 4
  • [3] pp. 96-97, (2007)
  • [4] 6