Modulation strategy for suppressing the common-mode voltage of an indirect matrix converter

被引:0
|
作者
Ma X. [1 ,2 ]
Kang Z. [1 ]
Zhao J. [1 ]
Pan Y. [1 ]
机构
[1] School of Electrical Engineering and Automation, Henan Polytechnic University, Jiaozuo
[2] Henan Key Laboratory of Intelligent Detection and Control of Coal Mine Equipment, Jiaozuo
基金
中国国家自然科学基金;
关键词
common mode voltage; indirect matrix converter; rectifier side; reference voltage; space vector modulation;
D O I
10.19783/j.cnki.pspc.230272
中图分类号
学科分类号
摘要
An indirect matrix converter will generate a large common mode voltage during operation, causing serious electromagnetic interference to the motor system and affecting the normal operation of the system. To address this issue, a new space vector modulation strategy is proposed to reduce the size of the common mode voltage and improve output voltage performance. First, the space vector of the rectifier stage is re-divided into regions, and three adjacent effective current vectors are selected based on the region where the reference current vector is located. The average DC bus voltage under the effective vector is maintained at a constant value to ensure the maximum output voltage of the rectifier stage. Second, the inverter stage adopts a ‘no zero vector’ modulation strategy, which suppresses the common mode voltage peak to 0.577 times the input phase voltage amplitude by synthesizing the required output voltage using three effective voltage vectors. Compared with traditional modulation strategies, the proposed modulation strategy not only reduces the computational burden of the system, but also reduces input and output harmonics, improving the quality of input and output waveforms. Finally, a corresponding model is built using Matlab/Simulink and an experimental platform, and the effectiveness of the proposed strategy is verified through simulation and experiment. © 2023 Power System Protection and Control Press. All rights reserved.
引用
下载
收藏
页码:1 / 10
页数:9
相关论文
共 24 条
  • [1] ZHENG Tao, SONG Weinan, LU Wenxuan, Asymmetric fault ride-through control strategy for a low frequency AC transmission system based on a modular multilevel matrix converter, Power System Protection and Control, 51, 8, pp. 107-117, (2023)
  • [2] YANG Xuhong, FANG Haoxu, JIA Wei, Research on fractional-order sliding-mode control of a direct matrix converter, Power System Protection and Control, 50, 19, pp. 158-166, (2022)
  • [3] AMMAR A, KANAAN H Y, MOUBAYED N, Et al., Original approach toward three-phase indirect matrix converters through hybrid PWM modulation and DSP implementation, IEEE Access, 8, pp. 45837-45852, (2020)
  • [4] SUN Yuwei, CHANG Jingtian, FU Chao, Et al., Harmonic characteristics analysis of modular multilevel matrix converter for fractional frequency transmission system, Electric Power Engineering Technology, 41, 5, pp. 21-30, (2022)
  • [5] MA Xinghe, REN Xin, YAN Bingyao, Et al., Strategy of reducing the common mode voltage modulation of a three-level matrix converter, Power System Protection and Control, 48, 21, pp. 49-57, (2020)
  • [6] VARAJAO D, ARAUJO R E., Modulation methods for direct and indirect matrix converters: a review, Electronics, 10, 7, (2021)
  • [7] HAMOUDA M, BLANCHETTE H F, AL-HADDAD K., Unity power factor operation of indirect matrix converter tied to unbalanced grid, IEEE Transactions on Power Electronics, 31, 2, pp. 1095-1107, (2015)
  • [8] HOSSEINKHANI V, SARVI M., A new five-level inverter with reduced leakage current for photovoltaic system applications, Protection and Control of Modern Power Systems, 7, 2, pp. 287-299, (2022)
  • [9] LI Shanhu, CAO Sunpeng, JIN Zhaoyang, Et al., Improved space vector modulation strategy with 50 % common-mode voltage reduction for indirect matrix converter, Electric Machines and Control, 26, 1, pp. 77-85, (2022)
  • [10] YANG Xuhong, FANG Haoxu, JIA Wei, Research on fractional-order sliding-mode control of a direct matrix converter, Power System Protection and Control, 50, 19, pp. 158-166, (2022)