Noise Analysis of Beam Position Monitor System in BEPCⅡ

被引:0
|
作者
Wang Z. [1 ,2 ]
Cao J. [1 ,2 ]
Wang Z. [1 ,2 ]
He J. [1 ]
Ma H. [1 ]
Sui Y. [1 ,2 ]
Yue J. [1 ]
机构
[1] Institute of High Energy Physics, Chinese Academy of Sciences, Beijing
[2] University of Chinese Academy of Sciences, Beijing
关键词
BPM; Mechanical vibration; Power spectrum; Resolution;
D O I
10.7538/yzk.2018.youxian.0494
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The ultra low emittance light source requires that the resolution of the beam position monitor (BPM) system reaches sub-μm magnitude. Under the laboratory conditions, the resolution of BPM electronics can reach the sub-μm, but the mechanical vibration of the BPM detector in the on-line machine will be an important factor to limit the resolution of BPM system to sub-μm. In order to meet the requirements of the 0.1 μm resolution of the BPM system for the High Energy Photon Source (HEPS), based on the BPM system in the BEPCⅡ, the comprehensive analysis including environmental vibration and beam data by using the power spectrum method was carried out to explore the factors that will affect the resolution of the BPM system. This paper begins with the relationship between the traditional measurement standard of BPM system resolution and the power spectrum. By analyzing the working principle of the BPM system, the location environment of BPM system and the measurement of the mechanical vibration level around BPM system, the low frequency spectrum of the BPM data can be obtained. The spectrum composition and analysis results of the BPM data show that the cable transmission will cause the rising of the spectrum baseline; the BPM detector is directly affected by the environmental vibration; the vibration of the characteristic frequency of the quadrupole magnet causes the rising of the peak value of specific frequency of the whole storage ring BPM data by the beam vibration. Combined with beam dynamics, the vibration source points can be inferred from the BPM data. © 2019, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:948 / 954
页数:6
相关论文
共 12 条
  • [1] Jiao Y., Xu G., Cui X.H., Et al., The HEPS project, Journal of Synchrotron Radiation, 25, 6, pp. 1611-1618, (2018)
  • [2] Bialowons W., Amirikas R., Bertolini A., Et al., Measurement of ground motion in various sites, (2007)
  • [3] Liu Y.H., Chung Y.C., Chen C.S., Vibration evaluation for deionized water pumps in TPS, International Particle Accelerator Conference (7th), (2016)
  • [4] Seryi A., Hendrickson L., Raimondi P., Et al., Simulation studies of the NLC with improved ground motion models, Physics, (2000)
  • [5] Lill R., Sereno N., Yang B., BPM stabiltiy studies for the APS MBA upgrade, Proceedings of IBIC16, (2017)
  • [6] Bartolini R., Huang H., Kay J., Et al., Analysis of beam orbit stability and ground vibrations at the diamond storage ring, Proceedings of EPAC, (1980)
  • [7] Amirikas R., Ehrlichmann H., Bialowons W., Et al., Ground motion and comparison of various sites, (2005)
  • [8] Tang S., Yin C., Liu D., Orbit noise analysis in Shanghai Synchrotron Radiation Facility storage ring, High Power Laser and Particle Beams, 22, 7, pp. 1631-1634, (2010)
  • [9] Hui-Zhou M., Gang X., Ge L., Et al., Preliminary study of residual orbit oscillation in BEPCⅡ, Chinese Physics C, 32, 10, pp. 849-856, (2008)
  • [10] Observatory grade weak motion broadband seismometer