Determination of Hydroxyethyl Hydrazine Nitrate by Hydrophilic Interaction Chromatography Coupled with Mass Spectrometry

被引:0
|
作者
Xu L.-N. [1 ]
Zhang X.-J. [1 ]
Zhao T. [1 ]
Li J. [1 ]
Fang T. [1 ]
机构
[1] Beijing Institute of Aerospace Testing Technology, Beijing
关键词
Hydrophilic interaction chromatography; Hydroxyethyl hydrazine nitrate; Mass spectrometry;
D O I
10.11943/CJEM2019325
中图分类号
学科分类号
摘要
A method based on hydrophilic interaction chromatography (HILIC) coupled with mass spectrometry (MS) was developed for determination of hydroxyethyl hydrazine nitrate (HEHN). The effects of the composition of mobile phase and parameters for MS detection were investigated on the optimization of chromatography separation, time required for analysis, and detection sensitivity. Good linearity is obtained under the concentration range of 0.01-0.1 μg•mL-1 with R2=0.9991, and the limit of detection of 1.2 ng•mL-1. Recovery of two HEHN samples with concentration of 0.0250 and 0.0900 μg•mL-1 is determined as 98.1% and 97.7%, respectively, while relative standard deviation (RSD) is no more than 1.6%, indicating good precision of the method. A real sample of liquid propellant is determined by this method, and the content of HEHN measured as 12.5%±0.3% is in accordance with the prepared concentration of 12.9%. © 2020, Editorial Board of Chinese Journal of Energetic Materials. All right reserved.
引用
收藏
页码:936 / 941
页数:5
相关论文
共 10 条
  • [1] ZHOU Yue, GONG Xu-bin, FANG Tao, Applicable discussion on HAN-based nontoxic monopropellant, Missiles and Space Vehicles, 4, pp. 32-35, (2015)
  • [2] ZHANG Zhi-yong, TENG Yi-gang, CHEN Xingqiang, Et al., HAN-based monopropellants containing HEHN, Chemical Propellants & Polymeric Materials, 9, 5, pp. 28-31, (2011)
  • [3] WANG Ying, LIU Wei-guo, ZHAO Bing, Et al., Determination of anhydrous hydrazine content by peak area normalization method, Chemical Analysis and Meterage, 25, 1, pp. 34-37, (2016)
  • [4] HOU Qian-qian, ZHANG Wen-shen, XU Feng, Et al., Determination of unsymmetrical dimethylhydrazine purity with gas chromatographic internal standard method, Chemical Propellants & Polymeric Materials, 14, 6, pp. 88-90, (2016)
  • [5] HU Li-rong, WU Zhi-jian, Investigation of errors for DT-3 analysis process, Journal of Astronautic Metrology and Measurement, 26, 6, pp. 52-55, (2006)
  • [6] ZHANG You-zhi, WANG Xuan-jun, LIU Xiang-xuan, Et al., The establishment of the automatic potentiometry for unsymmetrical dimethylhydrazine analysis, Journal of Instrumental Analysis, 25, 4, pp. 111-114, (2006)
  • [7] Isenberg S L, Carter M D, Crow B S, Et al., Quantification of hydrazine in human urine by HPLC-MS-MS, Journal of Analytical Toxicology, 40, pp. 248-254, (2016)
  • [8] Oh J A, Shin H S., Simple and sensitive determination of hydrazine in drinking water by ultra-high-performance liquid chromatography-tandem mass spectrometry after derivatization with naphthalene-2,3-dialdehyde, Journal of Chromatography A, 1395, pp. 73-78, (2015)
  • [9] Jandera P, Janas P., Recent advances in stationary phases and understanding of retentionin hydrophilic interaction chromatography. A review, Analytica Chimica Acta, 967, pp. 12-32, (2017)
  • [10] McCalley D V., Understanding and manipulating the separation in hydrophilic interaction liquid chromatography, 1523, pp. 49-71, (2017)