Assessment of harmonic emission level considering influence of harmonic impedance of wind farm

被引:0
|
作者
Tan P. [1 ]
Yang H. [1 ]
Ma X. [1 ]
Xu F. [1 ]
机构
[1] College of Electrical Engineering and Information Technology, Sichuan University, Chengdu
基金
中国国家自然科学基金;
关键词
Aggregated equivalent; Complex linear regression; Harmonic emission level; Harmonic impedance of wind farm side; Wind power;
D O I
10.16081/j.issn.1006-6047.2019.04.025
中图分类号
学科分类号
摘要
Wind turbine filter and reactive power compensation device lead to the result that the harmonic impedance of wind farm is not much larger than that of the utility, so the influence of harmonic impedance of wind farm should not be neglected when calculating harmonic emission value of wind farm. A method based on the improved complex linear regression equation is proposed for assessing the harmonic emission value of wind farm. The harmonic current components of wind farm side, which are not related with the regression equation coefficients, are separated from the harmonic voltage of PCC(Point of Common Coupling). Accordingly, a complex linear regression equation is established. The utility harmonic impedance is calculated by complex least square method. Considering the harmonic impedance of wind farm, the harmonic emission value is calculated. For the topology variability of wind farm feeder network, an equivalent and aggregation method for feeder network is proposed, by which, the hybrid feeder network is aggregated into T-shaped network to calculate the harmonic impedance of wind farm. The error marginal effect of dispersion parameters is used to analyze error. Simulation and measured data verify the effectiveness of the proposed method. © 2019, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:167 / 173
页数:6
相关论文
共 13 条
  • [1] Zhao Y., Shen H., Li J., Et al., Approach of identification and separation of harmonic sources, Proceedings of the CSEE, 22, 5, pp. 84-87, (2002)
  • [2] Yang H., Wang L., Assessing harmonic emission levels from non-loads using Laguerre polynomials, Proceedings of the CSEE, 25, 7, pp. 81-85, (2005)
  • [3] Xu W., Liu Y., A method for determining customer and utility harmonic contributions at the point of common coupling, IEEE Transactions on Power Delivery, 15, 2, pp. 804-811, (2000)
  • [4] Pfajfar T., Blazic B., Papic I., Harmonic contributions evalua-tion with the harmonic current vector method, IEEE Transactions on Power Delivery, 23, 1, pp. 425-433, (2007)
  • [5] Yang H., Pirotte P., Robert A., Harmonic emission levels of industrial loads statistical assessment, CIGRE Proceedings, pp. 1-7, (1996)
  • [6] Zhang W., Yang H., A method for assessing harmonic emission level based on binary linear regression, Proceedings of the CSEE, 24, 6, pp. 50-53, (2004)
  • [7] Xie S., Harmonic impedance analysis and harmonic assessment based on rank regression, Electric Power Automation Equipment, 30, 11, pp. 29-33, (2010)
  • [8] Hui J., Yang H.G., Lin S.F., Et al., Assessing utility harmonic impedance based on the covariance characteristic of random vectors, IEEE Transactions on Power Delivery, 25, 3, pp. 1778-1786, (2010)
  • [9] Hua H., Jia X., Cao D., Et al., A maximum likelihood method for harmonic impedance estimation, Proceedings of the CSEE, 34, 10, pp. 1692-1699, (2014)
  • [10] Zhao X., Yang H., A new method to calculate the utility harmonic impedance based on fastICA, IEEE Transactions on Power Delivery, 31, 1, pp. 381-388, (2016)