Holistic Operational Signatures for an energy-efficient district heating substation in buildings

被引:0
|
作者
Hong, Yejin [1 ]
Yoon, Sungmin [1 ,2 ]
机构
[1] Department of Global Smart City, Sungkyunkwan University, Suwon,16419, Korea, Republic of
[2] Division of Architecture and Urban Design, Incheon National University, Incheon,22012, Korea, Republic of
基金
新加坡国家研究基金会;
关键词
Energy efficiency - Buildings - Data mining - Flow of water - District heating;
D O I
暂无
中图分类号
学科分类号
摘要
District heating (DH) is recognized as a sustainable energy infrastructure in cities and buildings. DH substation operation is essential to bridging the gap between plants and thermal clients in achieving the intended DH values and visions. Therefore, in this study, an operation analysis method was developed for building-side DH substations. Specifically, Holistic Operational Signature (HOS) was suggested with multiple signature elements (x-OS) and representations to consider comprehensive operational correlations. A HOS-based analytics is proposed to provide more insights and sound reasoning about the DH substation design, operation, control, and heating efficiency potentials, compared with the existing Energy Signature. In a case study for winter, the proposed HOS method was applied to a target DH substation serving actual residential buildings using the real operational datasets. The six HOSs (HOSs 1–6) were derived with their six elements to identify the representative heating consumption levels and patterns, partial heating load ratios, and operation and control efficiency. Excessive water flow rates were identified based on the partial heating load elements (less than 50% in most cases) of all signatures. Inefficient signatures (HOSs 1–4) that do not follow the conventional control principle according to outdoor air temperatures were captured, especially for high heating demand patterns, which accounted for 72.5% of the total in winter. According to the signatures, the demand-based control can decrease the heating supply temperature setpoint by about 1.4 °C and 0.6 °C, respectively for HOS2 and the winter. It is recommended that the valve operation should be improved to lower the hunting levels (within ±1.5 °C) of heating water temperature control, especially in the afternoon with low heating demands. © 2022 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] Holistic Operational Signatures for an energy-efficient district heating substation in buildings
    Hong, Yejin
    Yoon, Sungmin
    ENERGY, 2022, 250
  • [2] Energy-efficient Tall buildings design strategies: A holistic approach
    Elotefy, Hazem
    Abdelmagid, Khaled S. S.
    Morghany, Ezzat
    Ahmed, Tarek M. F.
    INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY -TMREES15, 2015, 74 : 1358 - 1369
  • [3] Examination and Optimization of a Heating Circuit for Energy-Efficient Buildings
    Poettgen, Philipp
    Ederer, Thorsten
    Altherr, Lena
    Lorenz, Ulf
    Pelz, Peter F.
    ENERGY TECHNOLOGY, 2016, 4 (01) : 136 - 144
  • [4] Impact of heating strategies towards energy-efficient buildings
    Figueiredo, A.
    Almeida, R. M. S. F.
    Vicente, R.
    Ferreira, Victor M.
    ENERGY AND BUILDINGS, 2024, 315
  • [6] Low-energy district heating in energy-efficient building areas
    Dalla Rosa, A.
    Christensen, J. E.
    ENERGY, 2011, 36 (12) : 6890 - 6899
  • [8] ENERGY-EFFICIENT BUILDINGS
    ROSENFELD, AH
    HAFEMEISTER, D
    SCIENTIFIC AMERICAN, 1988, 258 (04) : 78 - &
  • [9] A new procedure for assessing the energy-efficient refurbishment of buildings on district scale
    Paiho, Satu
    Ketomaki, Jaakko
    Kannari, Lotta
    Hakkinen, Tarja
    Shemeikka, Jari
    SUSTAINABLE CITIES AND SOCIETY, 2019, 46
  • [10] New developments in illumination, heating and cooling technologies for energy-efficient buildings
    Han, H. J.
    Jeon, Y. I.
    Lim, S. H.
    Kim, W. W.
    Chen, K.
    ENERGY, 2010, 35 (06) : 2647 - 2653