Maximum Power Point Tracking Based on a New Hybrid Method for Automobile Exhaust Thermoelectric Generators

被引:0
|
作者
Li X. [1 ]
Xie C. [1 ]
Huang L. [1 ]
Quan S. [1 ]
Fang W. [1 ]
机构
[1] Automation of School, Wuhan University of Technology, Wuhan
关键词
Automotive exhaust thermoelectric generator; Hybrid method; Interleaved Buck converter; Maximum power tracking; Power losses; Voltage closed loop;
D O I
10.3901/JME.2019.16.132
中图分类号
学科分类号
摘要
To improve the dynamic tracking speed and steady accuracy of the automotive exhaust thermoelectric generator DC/DC maximum power algorithm, a novel iterative tracking algorithm is proposed based on the combination of the improved incremental conductance method and adaptive variable step size BP artificial neural network. Besides, an interleaved buck converterwith voltage closed loop is used, then based on building its small signal model compensation design is given to ensure high efficiency and system stability. Comparative experiments under two different engine steady and the dynamic conditions are carried out with a new hybrid method (HM) proposed and the single improved incremental conductance (SIINC) method, single BP artificial neural network (SBP-ANN) algorithm. Simulation and experimental results verify the feasibility and availability of the proposed algorithm, comparing with the SIINC method and SBP-ANN algorithm respectively, and in the steady state, the HM is approximately equal to the actual value and the power losses are the least, thus it is suitable forautomotive exhaust thermoelectric generator scenarios. The maximum power tracking technology based on a new hybrid method proposed has a strong reference value for designing the stable and efficient automotive exhaust thermoelectric generation system. © 2019 Journal of Mechanical Engineering.
引用
收藏
页码:132 / 140
页数:8
相关论文
共 22 条
  • [1] Carstens J.H., Guhmann C., Maximum power point controller for thermoelectric generators to support a vehicle power supply, 12th European Conference on Thermoelectrics, pp. 790-803, (2014)
  • [2] Kim S., Park S., Kim S.K., Et al., A thermoelectric generator using engine coolant for light-duty internal combustion engine-powered vehicles, Journal of Electronic Materials, 40, 5, pp. 812-816, (2011)
  • [3] Fang W., Quan S.H., Xie C.J., Et al., Maximum power point tracking with dichotomy and gradient method for automobile exhaust thermoelectric generators, Journal of Electronic Materials, 45, 3, pp. 1613-1624, (2016)
  • [4] Zhang T., New thinking on modeling of thermoelectric devices, Applied Energy, 168, pp. 65-74, (2016)
  • [5] He W., Wang S.X., Yang Y.R., Peak power evaluation and optimal dimension design of exhaust heat exchanger for different gas parameters in automobile thermoelectric generator, Energy Conversionand Management, 151, pp. 661-669, (2017)
  • [6] Wang Y.P., Li S., Xie X., Et al., Performance evaluation of an automotive thermoelectric generator with inserted fins or dimpled-surface hot heat exchanger, Applied Energy, 218, pp. 391-401, (2018)
  • [7] Cozar I.R., Pujol T., Lehocky M., Numerical analysis of the effects of electrical and thermal configurations of thermoelectric modules in large-scale thermoelectric generators, Applied Energy, 229, pp. 264-280, (2018)
  • [8] Quan R., Zhou W., Yang G., Et al., A hybrid maximum power pointtracking method for automobile exhaust thermoelectric generator, Journal of Electronic Materials, 46, 5, pp. 2676-2683, (2017)
  • [9] Jordehi A.R., Maximum power point tracking in photovoltaic (PV) systems: A review of different approaches, Renewable and Sustainable Energy Reviews, 65, pp. 1127-1138, (2016)
  • [10] Zhou D., Chen Y., Maximum power point tracking strategy based on modified variable step-size incremental conductance algorithm, Power System Technology, 39, 6, pp. 1491-1498, (2015)