Study on the process of medical waste disinfection by microwave technology

被引:0
|
作者
Liu, Jie [1 ]
Li, Haoru [1 ]
Liu, Zhibo [1 ]
Meng, Xiangwen [1 ,2 ]
He, Yan [1 ]
Zhang, Zhentao [2 ]
机构
[1] Qingdao University of Science and Technology, 266100, Qingdao, China
[2] Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 100190, Beijing, China
来源
Waste Management | 2022年 / 150卷
关键词
Bacteriology - Composting - Environmental technology - Microwave generation - Object detection - Sterilization (cleaning) - Testing - Waste disposal - Waste treatment;
D O I
暂无
中图分类号
学科分类号
摘要
Microwave sterilization technology is an environmentally friendly non-incineration disposal method for medical waste. The core sterilization technology of microwave sterilization, steam makes the system heat up quickly was adopted to build a microwave sterilization screw conveyor system that can continuously and dynamically type microwave sterilization. The platinum resistance temperature sensor is used to measure the temperature of the steam at the outlet of the system and the temperature of the material at the outlet. The microwave sterilization process for medical waste was studied on the microwave sterilization test platform, and the influence and regularity of three factors on the microwave sterilization effect were explored and the microwave sterilization process was optimized using the orthogonal test method. Bacillus subtilis var. black spore (ATCC 9372) was used as the detection object of microwave sterilization effect, and the sterilization rate was calculated by the total number of colonies after culture. The results show that, microwave sterilization time has the greatest influence on sterilization effect, the greater the microwave power, the longer the sterilization time, the higher the water content, the higher the sterilization rate. The orthogonal test results show that the optimal process parameters of the microwave sterilization system are the microwave power of 22 kW, the sterilization time of 480 s, and the moisture content of 90%, the sterilization rate is 99.9996%, the sterilization effect is good. When the microwave power is 25 kW or 28 kW, the sterilization time is 480 s or 600 s, and the water content is 90%, the sterilization rate is 100%. Considering the germicidal effect, equipment cost, saving power consumption, shortening the germicidal process time and other comprehensive factors, this process parameter can obtain the best benefit. It can be seen that the use of microwave sterilization technology to treat medical waste is fast and efficient, and does not produce dioxins and other harmful substances, safe and environmental protection, simple operation, excellent sterilization effect. © 2022 Elsevier Ltd
引用
收藏
页码:13 / 19
相关论文
共 50 条
  • [41] Study on the optimum process of microwave technology for soil treatment based on orthogonal experiment
    Ma, Dengsheng
    Zhang, Shuai
    Qing, Qi
    Lu, Xirui
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL ENGINEERING, 2017, 69
  • [42] Medical-Waste Chain: A Medical Waste Collection, Classification and Treatment Management by Blockchain Technology
    Hai Trieu Le
    Khoi Le Quoc
    The Anh Nguyen
    Khoa Tran Dang
    Hong Khanh Vo
    Huong Hoang Luong
    Hieu Le Van
    Khiem Huynh Gia
    Loc Van Cao Phu
    Duy Nguyen Truong Quoc
    Tran Huyen Nguyen
    Son, Ha Xuan
    Duong-Trung, Nghia
    COMPUTERS, 2022, 11 (07)
  • [43] Airborne disinfection using microwave-based technology: Energy efficient and distinct inactivation mechanism compared with waterborne disinfection
    Wang, Can
    Hu, Xurui
    Zhang, Zhiwei
    JOURNAL OF AEROSOL SCIENCE, 2019, 137
  • [44] Utilization of the Tail Gas and Waste Catalyst from the Petrochemical Process to Generate Syngas by Microwave-induced Technology
    Lo, Chin Chung
    Jou, Bo-Jyun
    Tsai, Tsung Yueh
    Lee, Chien Li
    Jou, Chih-Ju G.
    SENSORS AND MATERIALS, 2019, 31 (02) : 319 - 326
  • [45] Machine and process technology for medical products
    Maschinen- Und Verfahrenstechnik für Medizinprodukte
    Jensen, R. (jensenr@krauss-maffei.de), 2005, Carl Hanser Verlag (95):
  • [46] Digital Process Chains in the Medical Technology
    不详
    ATP EDITION, 2013, (04): : 8 - 8
  • [47] Machine and process technology for medical products
    Jensen, R
    KUNSTSTOFFE-PLAST EUROPE, 2005, 95 (04): : 82 - 85
  • [48] Disinfection and solubilization of sewage sludge using the microwave enhanced advanced oxidation process
    Yu, Y.
    Chan, W. I.
    Liao, P. H.
    Lo, K. V.
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 181 (1-3) : 1143 - 1147
  • [49] WASTE-WATER DISINFECTION WITH OZONE-PROCESS CONTROL AND OPERATING RESULTS
    RAKNESS, KL
    CORSARO, KM
    HALE, G
    BLANK, BD
    OZONE-SCIENCE & ENGINEERING, 1993, 15 (06) : 497 - 513
  • [50] STUDY ON MICROWAVE CURING OF RADIOACTIVE WASTE
    Xu, Yanze
    Ma, Yan
    Wei, Yanni
    Lu, Chenlin
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 5, 2014,