Lab-on-a-chip dielectrophoretic manipulation of beta-2 microglobulin for toxin removal in an artificial kidney

被引:0
|
作者
Samad M.I.A. [1 ]
Kayani A.A. [2 ]
Zoolfakar A.S. [3 ]
Hamzah A.A. [1 ]
Majlis B.Y. [1 ]
Buyong M.R. [1 ]
机构
[1] Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, Bangi
[2] Center for Advanced Materials and Green Technology, Multimedia University, Melaka
[3] NANOElecTronic Centre, NET, Universiti Teknologi Mara, UiTM, Shah Alam, 45450, Selangor
关键词
Artificial kidney; Beta-2-microglobulin; Dielectrophoresis; End-stage renal disease; Hollow fibre membrane; Lab on chip;
D O I
10.2174/1876402911666181218145459
中图分类号
学科分类号
摘要
Background: This paper presents a fundamental study of protein manipulation under the influence of dielectrophoretic (DEP) force for a lab-on-a-chip platform. Objective: Protein manipulation is dependent on the polarisation factor of protein when exposed to an electric field. Therefore the objective of this work is a microfluidic device and measurement system are used to characterise the human beta-2 microglobulin (β2M) protein via lateral attractive forces and vertical repulsive forces by means of DEP responses. Method: The manipulation of the β2M protein was conducted using a microfluidic platform with a tapered DEP microelectrode and the protein concentration was quantified based on a biochemical interaction using an Enzyme-Linked Immunosolvent Assay (ELISA). The protein distribution has been analysed based on the β2M concentration for each microfluidic outlet. Results: At 300 kHz, the protein experienced a negative DEP (nDEP) with of 83.3% protein distribution on the middle microchannel. In contrast, the protein experienced a positive DEP (pDEP) at 1.2 MHz with of 78.7% of protein on the left and right sides of the microchannel. Conclusion: This is concept proved that the tapered DEP microelectrode is capable of manipulating a β2M via particle polarisation, hence making it suitable to be utilised for purifying proteins in biomedical application. © 2019 Bentham Science Publishers.
引用
收藏
页码:40 / 46
页数:6
相关论文
共 28 条
  • [1] Parametric study on the geometrical parameters of a lab-on-a-chip platform with tilted planar electrodes for continuous dielectrophoretic manipulation of microparticles
    Arash Dalili
    Erfan Taatizadeh
    Hamed Tahmooressi
    Nishat Tasnim
    Pamela Inés Rellstab-Sánchez
    Matthew Shaunessy
    Homayoun Najjaran
    Mina Hoorfar
    Scientific Reports, 10
  • [2] Parametric study on the geometrical parameters of a lab-on-a-chip platform with tilted planar electrodes for continuous dielectrophoretic manipulation of microparticles
    Dalili, Arash
    Taatizadeh, Erfan
    Tahmooressi, Hamed
    Tasnim, Nishat
    Rellstab-Sanchez, Pamela Ines
    Shaunessy, Matthew
    Najjaran, Homayoun
    Hoorfar, Mina
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] In vitro characterisation of phosphate and beta-2 microglobulin removal by The Gradiflow™.
    Lee, JI
    Nair, H
    Harris, DCH
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 418A - 418A
  • [4] EFFECTIVENESS OF SERUM BETA-2 MICROGLOBULIN AS A TOOL TO EVALUATE KIDNEY STATUS
    Moon, Gil Sung
    Shin, In Sik
    Kim, Sung Hoon
    TRANSPLANT INTERNATIONAL, 2019, 32 : 326 - 326
  • [5] Rediscovering Beta-2 Microglobulin As a Biomarker across the Spectrum of Kidney Diseases
    Argyropoulos, Christos P.
    Chen, Shan Shan
    Ng, Yue-Harn
    Roumelioti, Maria-Eleni
    Shaffi, Kamran
    Singh, Pooja P.
    Tzamaloukas, Antonios H.
    FRONTIERS IN MEDICINE, 2017, 4
  • [6] Serum Beta-2 Microglobulin at Discharge Predicts Outcomes after Kidney Transplantation
    Astor, B. C.
    Muth, B.
    Kaufman, D.
    Pirsch, J. D.
    Hofmann, R. M.
    Djamali, A. X.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2012, 12 : 166 - 166
  • [7] BETA-2 MICROGLOBULIN REMOVAL DURING CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS (CAPD)
    LYSAGHT, MJ
    POLLOCK, CA
    MORAN, JE
    IBELS, LS
    FARRELL, PC
    PERITONEAL DIALYSIS INTERNATIONAL, 1989, 9 (01): : 29 - 35
  • [8] Effectiveness of serum beta-2 microglobulin as a tool for evaluating donor kidney status for transplantation
    Sung Whan Cha
    In Sik Shin
    Deok Gie Kim
    Sung Hoon Kim
    Jun Young Lee
    Jae Seok Kim
    Jae Won Yang
    Byoung-Geun Han
    Seung Ok Choi
    Scientific Reports, 10
  • [9] Effectiveness of serum beta-2 microglobulin as a tool for evaluating donor kidney status for transplantation
    Cha, Sung Whan
    Shin, In Sik
    Kim, Deok Gie
    Kim, Sung Hoon
    Lee, Jun Young
    Kim, Jae Seok
    Yang, Jae Won
    Han, Byoung-Geun
    Choi, Seung Ok
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] BETA-2 MICROGLOBULIN (BETA-2M) REMOVAL IN HEMODIAFILTRATION (HDF) AFTER REPROCESSING DIALYZERS WITH PEROXYACETIC ACID
    KERR, PG
    ARGILES, A
    CANAUD, B
    FLAVIER, JL
    MION, C
    KIDNEY INTERNATIONAL, 1992, 42 (04) : 1045 - 1045