Stockbridge dampers for extending the fatigue life of a cable at St Nazaire cable stayed bridge

被引:0
|
作者
Berthellemy, Jacques [1 ]
Siegert, Dominique [2 ]
Berton, Édouard [3 ]
Quentin, Pierre [4 ]
机构
[1] Steel Bridges Engineering Expert at Cerema, France
[2] COSYS/IMSE, University Gustave Eiffel, France
[3] Engineer at Cerema, France
[4] Engineer at Loire-Atlantique Local Authority, France
关键词
Anchorages (foundations) - Bridge cables - Buffeting - Cable stayed bridges - Vortex flow;
D O I
暂无
中图分类号
学科分类号
摘要
The failure of a stay cable on the Saint-Nazaire bridge is investigated in detail. In 2000, fatigue cracks that had cut many wires led to a first replacement, alike to the initial, of the H32 stay cable. Examination of the deposited locked coil strand showed that fretting fatigue was involved in the wire breaks. The cause of the failures at the anchorages is discussed/studied in depth in the paper. Bending moments of the rigid cable, at its exit from the anchorage socket were proven to be the source of the fatigue stress due to vibrations induced by vortex detachments (VIV: Vortex Induced Vibrations). As wires ruptures occurred again in 2017 in the new H32 stay cable at the same place, further studies on dampers were carried out. After numerical simulations, the Stockbridge damper became a good candidate for attenuating the amplitude of vibrations. It could indeed be designed to fit the required frequency range between 30 and 35 Hz. © 2022
引用
收藏
相关论文
共 50 条
  • [1] Stockbridge dampers for extending the fatigue life of a cable at St Nazaire cable stayed bridge
    Berthellemy, Jacques
    Siegert, Dominique
    Berton, Edouard
    Quentin, Pierre
    ENGINEERING FAILURE ANALYSIS, 2022, 141
  • [2] Fatigue life assessment of FRP cable for long-span cable-stayed bridge
    Feng, Bo
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2019, 210 : 159 - 166
  • [3] Damping cable vibration for a cable-stayed bridge using adjustable fluid dampers
    Xu, Y. L.
    Zhou, H. J.
    JOURNAL OF SOUND AND VIBRATION, 2007, 306 (1-2) : 349 - 360
  • [4] Influence of Cable Dampers on Cable-Stayed Bridges
    Liang, Dong
    Shen, Huicai
    Li, Yanfeng
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 1474 - 1479
  • [5] Influence of cable dampers on cable-stayed bridges
    Liang, Dong
    Kong, Dandan
    Li, Yanfeng
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-BRIDGE ENGINEERING, 2014, 167 (04) : 293 - 302
  • [6] Seismic response control of a cable-stayed bridge by variable dampers
    Ruangrassamee, A
    Kawaskima, K
    JOURNAL OF EARTHQUAKE ENGINEERING, 2006, 10 (01) : 153 - 165
  • [7] Cable Stress Monitoring for a Cable Stayed Bridge
    Cao, Y.
    Wang, M. L.
    STRUCTURAL HEALTH MONITORING 2010, 2010, : 1196 - 1201
  • [8] Seismic Response Reduction of Cable-Stayed Bridge with Viscous Dampers
    Qiu, Wenliang
    Jiang, Meng
    Zhang, Xingbo
    APPLIED MECHANICS AND CIVIL ENGINEERING, 2012, 137 : 154 - +
  • [9] Effectiveness of Smart Dampers for Hybrid FRP Cable in Long-Span Cable-Stayed Bridge
    Wang, Xin
    Wu, Zhishen
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 243 - 247
  • [10] Cable stressing sequence of an asymmetrical cable stayed bridge
    Anderson, J.R.B., 2013, Taylor and Francis - Balkema