Air-cooled condensers optimization for novel Ultra-Low Charge ammonia chillers to achieve competitive packaged units

被引:2
|
作者
Expósito Carrillo J.A. [1 ,2 ]
Gomis Payá I. [3 ]
Peris Pérez B. [4 ]
Sánchez de La Flor F.J. [1 ]
Salmerón Lissén J.M. [3 ]
机构
[1] Escuela Superior de Ingeniería, Departamento de Máquinas y Motores Térmicos, Universidad de Cádiz, Avda. de la Universidad de Cádiz, Puerto Real
[2] Intarcon S.L, Bulevar de los Santos 34, Córdoba, Lucena
[3] Escuela Técnica Superior de Ingeniería, Departamento de Ingeniería Energética, Universidad de Sevilla, Camino de los Descubrimientos s/n, Sevilla
[4] Escuela de Ingenierías Industriales, Departamento de Ingeniería Mecánica, Térmica y Fluidos, Universidad de Málaga, C/Doctor Ortiz Ramos s/n, Málaga
关键词
Air-cooled chiller; Energy efficiency; Optimisation; R717; Ultra-low-charge;
D O I
10.1016/j.applthermaleng.2022.119347
中图分类号
学科分类号
摘要
Novel Ultra-Low Charge (ULC) ammonia chillers are being investigated as a highly efficient and sustainable solution in the field of refrigeration with natural fluids. These chillers were conceived to minimize the refrigerant charge using air-cooled condensers, semi-hermetic compressors, and direct expansion evaporators, becoming reliable solutions for commercial and industrial applications. However, the economic feasibility of ULC packaged units is still questioned, in the long term, compared to traditional ammonia chillers. Accordingly, this paper focuses on the air-cooled condensers optimization due to both, its investment cost relevancy over the packaged unit and its direct influence on the system performance. For this purpose, the experimental performance data of a commercial ULC ammonia chiller of 230 kW have been used to validate a numerical model which predicts the Seasonal Performance Energy Ratio (SEPR) and the Net Present Value (NPV) of the unit. Considering the commercial unit as the baseline case, the number of parallel condensers together with the condensing set point have been optimised to maximise the NPV along the lifetime expectancy of the unit. The results reported an optimal condensing temperature of 12 K above the outdoor temperature for the operating conditions defined in the Eco-Design Directive 2015/1095 and an optimal number of single parallel condensers which ranges from four to six depending on the lifetime considered and the interest rate. Likewise, the NPV varies from 4 000 €, at the fifth year of operation, up to a range between 15 000 € and 35 000 € at the twentieth year of operation. © 2022
引用
收藏
相关论文
共 4 条
  • [1] Microchannel heat exchangers for charge minimization in air-cooled ammonia condensers and chillers
    Hrnjak, Pega
    Litch, Andy D.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (04): : 658 - 668
  • [2] Experimental performance analysis of a novel ultra-low charge ammonia air condensed chiller
    Exposito Carrillo, Jose Antonio
    Gomis Paya, Ignacio
    Peris Perez, Bernardo
    Sanchez de la Flor, Francisco Jose
    Salmeron Lissen, Jose Manuel
    APPLIED THERMAL ENGINEERING, 2021, 195
  • [3] Multi-Objective optimisation of oil demisters geometry for Ultra-Low charge ammonia chillers
    Carrillo, Jose Antonio Exposito
    Paya, Ignacio Gomis
    Lissen, Jose Manuel Salmeron
    de la Flor, Francisco Jose Sanchez
    Pardo, Alvaro Ruiz
    APPLIED THERMAL ENGINEERING, 2024, 251
  • [4] Optimization of ammonia injection grid in hybrid selective non-catalyst reduction and selective catalyst reduction system to achieve ultra-low NOx emissions
    Zhou, Hao
    Guo, Xutao
    Zhou, Mingxi
    Ma, Weiwei
    Dahri, Muhammad Waryal
    Cen, Kefa
    JOURNAL OF THE ENERGY INSTITUTE, 2018, 91 (06) : 984 - 996