The thermally renovation method for built houses is expected to contribute to the global warming prevention. In this paper the analyzed results of the indoor thermal environments during heating season and annual energy consumption in four detached houses before and after the retrofit were presented. In particular, non energy benefit (NEB) could be useful for the evaluation of cost benefit after renovation. It is said that there are three kinds of renovated methods for improvement of thermal performance on the envelopes in according with the width of insulated area. This paper focuses on the environmental improvement of houses through the whole and partial renovation method. © 2020 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:597 / 601
页数:4
相关论文
共 50 条
  • [1] Environmental impact of cool roof paint: case-study of house retrofit in two hot islands
    Shittu, Emmanuel
    Stojceska, Valentina
    Gratton, Petra
    Kolokotroni, Maria
    ENERGY AND BUILDINGS, 2020, 217
  • [2] Retrofit modelling of existing dwellings in the UK: the Salford Energy House case study
    Ji, Yingchun
    Lee, Angela
    Swan, William
    INTERNATIONAL JOURNAL OF BUILDING PATHOLOGY AND ADAPTATION, 2019, 37 (03) : 344 - 360
  • [3] IMPROVEMENT OF ENVIRONMENTAL MANAGEMENT: A CASE STUDY
    Takic, Ljiljana
    Zivkovic, Snezana
    Zivkovic, Nenad
    FRESENIUS ENVIRONMENTAL BULLETIN, 2013, 22 (12C): : 3840 - 3847
  • [4] A CASE STUDY OF PARTIAL INSULATION RETROFIT OF A DETACHED HOUSE CONSIDERING ENERGY CONSUMPTION AND HEALTH
    Fujii K.
    Arai H.
    Wakabayashi K.
    Fukawa Y.
    Tobe R.
    Nagai T.
    Nakagawa J.
    Tanabe S.-I.
    Journal of Environmental Engineering (Japan), 2022, 87 (802): : 895 - 906
  • [5] CASE STUDY ON THE APPLICABILITY OF INTERNAL INSULATION RETROFIT IN A WOODEN DETACHED HOUSE WITH SOUNDPROOF WORK
    Ayaka, Kani
    Satoshi, Aihara
    Ineko, Tanaka
    AIJ Journal of Technology and Design, 30 (75): : 838 - 843
  • [6] Quay Crane Performance Improvement and Lifecycle Extension: Retrofit Determination - A Case Study
    Gothandapani, Sundaraja Perumal A.
    Rahman, Mohd Nizam Ab
    Hishamuddin, Hawa
    JURNAL KEJURUTERAAN, 2024, 36 (04): : 1483 - 1493
  • [7] A bioregional approach environmental building to - A case study of the KST house
    Cohen, DH
    Yamaguchi, A
    Spengler, JD
    BUILDINGS, CULTURE AND ENVIRONMENT: INFORMING LOCAL AND GLOBAL PRACTICES, 2003, : 307 - 331
  • [8] Energy retrofit and environmental sustainability improvement of a historical farmhouse in Southern Italy
    Congedo, Paolo Maria
    Baglivo, Cristina
    Zaca, Ilaria
    D'Agostino, Delia
    Quarta, Fabrizio
    Cannoletta, Alessandro
    Marti, Antonio
    Ostuni, Valeria
    CLIMAMED 2017 - MEDITERRANEAN CONFERENCE OF HVAC HISTORICAL BUILDINGS RETROFIT IN THE MEDITERRANEAN AREA, 2017, 133 : 367 - 381
  • [9] Effect of Climate Changes on Renewable Production in the Mediterranean Climate: Case Study of the Energy Retrofit for a Detached House
    De Masi, Rosa Francesca
    Festa, Valentino
    Gigante, Antonio
    Mastellone, Margherita
    Ruggiero, Silvia
    Vanoli, Giuseppe Peter
    SUSTAINABILITY, 2021, 13 (16)
  • [10] Green Roof Retrofit: A Case Study
    Rahman, Md Motiar
    Shams, Shahriar
    Ismail, Pengiran Haji Ros Ismandi Pengiran
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2021, 13 (07): : 81 - 88