Xenon enrichment effect by gas membrane separation technology

被引:0
|
作者
Liu W. [1 ]
Lyu X. [1 ]
Quan W. [1 ]
Yu Z. [1 ]
Wang H. [1 ]
机构
[1] Nuclear and Radiation Safety Center, MEE, Beijing
关键词
!sup]133[!/sup]Xe; effluent monitoring; enrichment characteristics; gas separation membrane; inert gas; radiation monitoring; xenon enrichment; xenon isotopes;
D O I
10.11990/jheu.202206014
中图分类号
学科分类号
摘要
Increasing the gas sampling amount is necessary to solve the substantially higher lower detection limit of radioactive inert gas monitoring in nuclear facilities in China than its actual sampling activity. A nitrogen and oxygen separation membrane is selected to design and set up a set of experimental devices for xenon separation and enrichment to improve radioactive xenon isotope in the airborne effluent. The concentration effect of xenon in the air was tested under different sampling multiples. The gas film enrichment effect of xenon in the air was studied by comparing the sampling multiples, and the influence of the lower detection limit in the onsite sampling laboratory analysis was theoretically calculated. Results showed that by using the air film separation technology, the amount of radioactive xenon sampled in the airborne effluent can be increased to approximately 15 times, thereby reducing the detection limit for radioactive xenon by approximately 15 times when the sampling multiple is 124. 2. © 2022 Editorial Board of Journal of Harbin Engineering. All rights reserved.
引用
收藏
页码:1611 / 1614
页数:3
相关论文
共 12 条
  • [1] WANG Zilu, WANG Wei, TUO Fei, Et al., Current status of traceability of radioactive inert gas (Kr, Xe) monitoring system in China, Chinese journal of radiological health, 28, 6, pp. 730-733, (2019)
  • [2] LIU Shuang, ZHANG Yang, ZHANG Tianmeng, Et al., Preparation and characterization of 3-(2-aminoethylamino) propylmethyldimethoxysilane-nano cellulose aerogels, Acta materiae compositae sinica, 35, 11, pp. 3180-3188, (2018)
  • [3] ZHOU Guoqing, Study on the xenon enrichment and gaseous impurities removal by using polyimide hollow fiber membranes, (2016)
  • [4] (2016)
  • [5] 3, pp. 58-61, (2006)
  • [6] CHANG Yinzhong, ZHANG Shengdong, CHEN Zhanying, Et al., Study on efficient purification and preparation of rad-ioxenon sample by adsorption at normal temperature, Atomic energy science and technology, 55, 4, pp. 612-619, (2021)
  • [7] CAO Jianhua, YANG Xiaoyong, WANG Jie, Et al., Design and research of a laboratory-scale helium purification test facility based on membrane, Experimental technology and management, 25, 1, pp. 38-40, (2008)
  • [8] (2015)
  • [9] (2010)
  • [10] ZHANG Lin, CO<sub>2</sub> capture by membrane process from coal-fired wet desulfurized flue gas and the failure mechanism, (2017)