Optimal Dynamic Voltage Restorer Using Water Cycle Optimization Algorithm

被引:1
|
作者
Thongsan T. [1 ]
Chatchanayuenyong T. [1 ]
机构
[1] Faculty of Engineering, Mahasarakham Univeristy, Maha Sarakham
来源
关键词
Dynamic voltage restorer; FOPI controller; FOPID controller; Water cycle algorithm;
D O I
10.32604/csse.2023.027966
中图分类号
学科分类号
摘要
This paper proposes a low complexity control scheme for voltage control of a dynamic voltage restorer (DVR) in a three-phase system. The control scheme employs the fractional order, proportional-integral-derivative (FOPID) controller to improve on the DVR performance in order to enhance the power quality in terms of the response time, steady-state error and total harmonic distortion (THD). The result obtained was compared with fractional order, proportional-integral (FOPI), proportional-integral-derivative (PID) and proportional-integral (PI) controllers in order to show the effectiveness of the proposed DVR control scheme. A water cycle optimization algorithm (WCA) was utilized to find the optimal set for all the controller gains. They were used to solve four power quality issues; balanced voltage sag, balanced voltage swell, unbalanced voltage sag, and unbalanced voltage swell. It showed that one set of controller gain obtained from the WCA could solve all the power quality issues while the others in the literature needed an individual set of optimal gain for each power quality problem. To prove the concept, the proposed DVR algorithm was simulated in the MATLAB/Simulink software and the results revealed that the four optimal controllers can compensate for all the power quality problems. A comparative analysis of the results in various aspects of their dynamic response and %THD was discussed and analyzed. It was found that PID controller yields the most rapid performance in terms of average response time while FOPID controller yields the best performance in term of average % steady-state error. FOPI controller was found to provide the lowest THD percentage in the average %THD. FOPID did not differ much in average response from the PID and average %THD from FOPI; however, FOPID provided the most outstanding average steady-state error. According to the CBMA curve, the dynamic responses of all controllers fall in the acceptable power quality area. The total harmonic distortion (THD) of the compensated load voltage from all the controllers were within the 8% limit in accordance to the IEEE std. 519-2014. © 2023 CRL Publishing. All rights reserved.
引用
下载
收藏
页码:595 / 623
页数:28
相关论文
共 50 条
  • [1] OPTIMIZATION OF VOLTAGE SAG/SWELL USING DYNAMIC VOLTAGE RESTORER (DVR)
    Saxena, Ragini
    Kushwah, Manorma
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, AND OPTIMIZATION TECHNIQUES (ICEEOT), 2016, : 4046 - 4051
  • [2] Dynamic voltage restorer-based power quality optimization using differential evolution algorithm
    Saveca, John
    Wang, Zenghui
    Sun, Yanxia
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2019), 2019, 35 : 573 - 579
  • [3] Design and performance of dynamic voltage restorer using genetic algorithm
    Kassarwani, Neelam
    Ohri, Jyoti
    Singh, Alka
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2018, 105 (01) : 88 - 103
  • [4] Multilevel Optimal Predictive Dynamic Voltage Restorer
    Dionisio Barros, J.
    Fernando Silva, J.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (08) : 2747 - 2760
  • [5] Optimization of dynamic control systems using water cycle algorithm
    Alimorad, Hajar
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2024, 361 (08):
  • [6] Optimal Dynamic Voltage Restorer Controller for Voltage Sag Compensation
    Farhadi, Faranak
    Solat, Sajjad
    Mahdioun, Seyyed Hamed
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 1705 - 1708
  • [7] Unbalanced Voltage Sag Correction with Dynamic Voltage Restorer Using Particle Swarm Optimization
    Kumar, D. J. R. S. S.
    Sasitharan, S.
    Mishra, Mahesh K.
    Kumar, B. Kalyan
    PROCEEDINGS OF THE INDICON 2008 IEEEE CONFERENCE & EXHIBITION ON CONTROL, COMMUNICATIONS AND AUTOMATION, VOL II, 2008, : 400 - 405
  • [8] Algorithm for Rapid Detection of Voltage Disturbance in Dynamic Voltage Restorer
    Han, B.
    Bae, B.
    Lee, J.
    Lee, H.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 1850 - 1855
  • [9] An improved approach for robust control of dynamic voltage restorer and power quality enhancement using grasshopper optimization algorithm
    Omar, Ahmed I.
    Aleem, Shady H. E. Abdel
    El-Zahab, Essam E. A.
    Algablawy, Mostafa
    Ali, Ziad M.
    ISA TRANSACTIONS, 2019, 95 : 110 - 129
  • [10] Power Quality Improvement in Distribution System Based on Dynamic Voltage Restorer Using Rational Energy Transformative Optimization Algorithm
    L. Nagarajan
    M. Senthilkumar
    Journal of Electrical Engineering & Technology, 2022, 17 : 121 - 137