Impact of Fuel Cell System on Under Frequency Load Shedding Scheme Design

被引:0
|
作者
Jha R. [1 ]
Khan B. [2 ]
机构
[1] Department of Electrical & Electronics Engineering, Allenhouse Institute of Technology, Kanpur
[2] Department of Electrical and Computer Engineering, Hawassa University, Hawassa
关键词
Critical frequency; critical load; fuel cell system (FCS); proportional integral (PI) controller; under frequency load shedding (UFLS);
D O I
10.13052/dgaej2156-3306.3752
中图分类号
学科分类号
摘要
The drop in frequency is a direct consequence of generation deficiency, either due to loss of generation or an increase in load. Therefore, in this work, to compensate for this generation deficiency following large disturbances, a fuel cell system (FCS) could be the most effective counter-measure.With the introduction of a proportional-integral (PI) controller to the FCS, the power output of the FCS can be further modified. In the present work, a two-area hydro-thermal interconnected system is being considered and simulated in MATLAB with and without FCS. From the simulation results, it is found that by using a FCS (with and without PI), the load shedding amount is reduced and the under-frequency load shedding (UFLS) scheme is made more effective. © 2022 River Publishers.
引用
收藏
页码:1329 / 1348
页数:19
相关论文
共 50 条
  • [1] The Method of Design an Optimal Under-Frequency Load Shedding Scheme
    Lytvynchuk, Volodymyr A.
    Kaplin, Mykola I.
    Bolotnyi, Nickolai P.
    2019 IEEE 6TH INTERNATIONAL CONFERENCE ON ENERGY SMART SYSTEMS (2019 IEEE ESS), 2019, : 14 - 17
  • [2] A review of under-frequency load shedding scheme on TNB system
    Zin, AAM
    Hafiz, HM
    Aziz, MS
    NATIONAL POWER & ENERGY CONFERENCE: PECON 2004, PROCEEDINGS, 2004, : 170 - 174
  • [3] Design of an under voltage load shedding scheme
    Mechenbier, J
    Ellis, A
    Curtner, R
    Ranade, S
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1611 - 1618
  • [4] An Under-Frequency Load Shedding Scheme Design for a Large Steelworks with Self-Generation System
    Lee, Sang-Seok
    Park, Ji-Ho
    Jeong, Ki-Seok
    Kim, Heung-Guen
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (05) : 1128 - 1136
  • [5] An Adaptive Under Frequency Load Shedding Scheme for a Small Island Power System
    Powell, C.
    Bahadoorsingh, S.
    Singh, A.
    Sharma, C.
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [6] Continuous Under-Frequency Load Shedding Scheme for Power System Adaptive Frequency Control
    Li, Changgang
    Wu, Yue
    Sun, Yanli
    Zhang, Hengxu
    Liu, Yutian
    Liu, Yilu
    Terzija, Vladimir
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (02) : 950 - 961
  • [7] Impact of Load Shedding on Frequency and Voltage System
    Budi, Irrine S.
    Nurdiansyah, Aziz
    Lomi, Abraham
    2017 INTERNATIONAL SEMINAR ON INTELLIGENT TECHNOLOGY AND ITS APPLICATIONS (ISITIA), 2017, : 110 - 115
  • [8] A new under-frequency load shedding scheme considering load frequency characteristics
    Xiong, Xiaofu
    Li, Wenyuan
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 1113 - +
  • [9] Decentralized Adaptive Under Frequency Load Shedding Scheme Based on Load Information
    He, Peican
    Wen, Buying
    Wang, Huaiyuan
    IEEE ACCESS, 2019, 7 : 52007 - 52014
  • [10] An approach to design power system under frequency load shedding scheme taking coherent area and global optimization into account
    Xie, Da
    He, Heng-Jing
    Chang, Xi-Qiang
    Yao, Xiu-Ping
    Dianwang Jishu/Power System Technology, 2010, 34 (06): : 106 - 112