Performance analysis of axial compressive behavior for precast steel plate-concrete composite silo wall of underground silo

被引:0
|
作者
Wang Z. [1 ]
Hou Z. [1 ]
Zhang Q. [1 ]
Chuai J. [1 ]
机构
[1] School of Civil Engineering, Henan University of Technology, Zhengzhou
关键词
Finite element analysis; Joint; Mechanical performance; Silo wall; Simplified calculation; Underground silo;
D O I
10.11975/j.issn.1002-6819.2021.01.008
中图分类号
学科分类号
摘要
An underground silo is essential to green grain storage, due to its low temperature, low land consumption, energy conservation, and environmental protection. A new underground silo was proposed in combination with the prefabricated technology and combined structure technology in the engineering practice. In this study, a finite element model of steel plate-concrete composite silo wall containing stud was established on the ABAQUS software, in order to explore the compressive properties of assembled underground silo using the full-scale axial compression test. A nonlinear finite element model of silo wall specimen was also established, concurrently considering the plastic damage of concrete and the elastoplasticity of steel plate. A simulation was performed on the whole loading process of specimens, thereby to analyze the mechanical properties and working mechanism. Various parameters were determined, such as the steel plate strength, concrete strength, and distance thickness ratio. The results showed that: The finite element simulation was in good agreement with the test. Moreover, the relative difference of axial deformation between the simulated and experimental value was 4.2% at 5 000 kN, indicating an applicable finite element model. The precast block concrete and the joint sealing-up steel plate could bear the load of 79.7%, and 50.9%, respectively, during the elastic stage. The peak load depended mainly on the precast concrete of silo wall and the load transfer of steel plates. There was more load in the sealing-up steel plate at the joint position after reaching the peak load. As such, strengthening the sealing-up steel plate can be used to improve the ductility of the specimen. There was the greatest influence of concrete strength on the initial stiffness and the ultimate bearing capacity of specimens, compared with the strength of steel plate, the distance thickness ratio, and sealing-up steel plate thickness. The regression coefficient of concrete strength, steel plate strength, distance thickness ratio, and sealing-up steel plate thickness to peak load were 0.910, 0.154, -0.005, and 0.301, respectively. The specimens were prone to brittle failure, due to the small strength and thickness of sealing-up steel plate. Two curves of load-deformation model were proposed in combination with the load-deformation curves for the silo wall specimens with the assembled steel plate-concrete composite under the various parameters. Furthermore, the simplified formula was also proposed for the axial peak load of the assembled steel plate-concrete composite silo wall. The relative difference of peak loads obtained by the calculation formula and the finite element method was not more than 9%, indicating high accuracy of calculation. The research findings can provide potential guidance for the engineering design of prefabricated underground silo wall. © 2021, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
引用
收藏
页码:59 / 67
页数:8
相关论文
共 30 条
  • [1] (2015)
  • [2] Zheng Pei, Wang Zhenqing, Yu Hanhua, Brief history and characteristic of underground warehouse in china, Cereals and Oils Processing, 1, pp. 90-94, (2009)
  • [3] Xiong Xiaoli, Jin Libing, Wang Zhenqing, Earth pressure and bearing capacity analysis on the wall of reinforced concrete underground granary, Journal of Basic Science and Engineering, 1, pp. 103-114, (2016)
  • [4] Jin Libing, Liu Feixiao, Tian Dongjie, Anti-floating test in construction and closed-water test process of underground reinforced concrete silos, Journal of Henan University of Technology: Natural Science Edition, 38, 2, pp. 105-108, (2017)
  • [5] Jin Libing, Liang Xinya, Huo Chengding, Et al., Engineering test and numerical analysis of underground concrete silo, Journal of Civil and Environmental Engineering (Chinese and English), 42, 3, pp. 40-45, (2020)
  • [6] Chen Guixiang, Cui Chenxing, Fu Zhiyong, Et al., Monitoring analysis on the stress of reinforced concrete underground grain silo, Journal of Henan University of Technology: Natural Science Edition, 37, 6, pp. 90-95, (2016)
  • [7] Xiong Xiaoli, Jin Libing, Shi Xiaoke, Et al., Study on wall bearing capacity calculation method of reinforced concrete underground granary, Journal of Henan University of Technology: Natural Science Edition, 36, 1, pp. 95-99, (2015)
  • [8] Zhou Chunlei, Study on Mechanical Behavior of invert tapered Shell bottom board structure for Large-Diameter Reinforced Concrete Underground Silo, (2003)
  • [9] Jia Tengnan, Wall Stress Analysis of Reinforced Concrete Underground Granary Based on the Space Stress, (2014)
  • [10] Zhang Hao, Xi Han, Tao Yuanqing, Analysis of mechanical properties under water pressure of lined plastic waterproof board, New Building Materials, 47, 4, pp. 157-160, (2020)