A compare research on third harmonic current control for five-phase permanent magnet synchronous motor

被引:0
|
作者
Li T. [1 ]
Ma R. [1 ]
Bai H. [1 ]
Fan P. [1 ]
Zhang Y. [1 ]
机构
[1] School of Automation, Northwestern Polytechnical University, Xi'an
关键词
Electromagnetic torque; Five-phase permanent magnet synchronous motor; Space vector pulse width modulation(SVPWM); Third harmonic current injection;
D O I
10.1051/jnwpu/20213940865
中图分类号
学科分类号
摘要
The injection of a third harmonic current can improve the electromagnetic torque output of the five-phase permanent magnet synchronous motor. In this paper, constant copper consumption and constant maximum current are used as constraints, and the influence of the ratio between the third harmonic current and the fundamental current on the electromagnetic torque under the two constraints is analyzed. The electromagnetic torque is the largest when the third harmonic current reference value is equal to the fundamental current reference value of ψf3/ψf times under the premise of the constant copper loss. On the premise that the maximum current is constant, the electromagnetic torque is the largest when the third harmonic current reference value is equal to the fundamental current reference value of kw/(6kw-kw3/3) times. On this basis, according to the vector amplitude, phase and action time, the changing trends of maximum voltage utilization rate with Vref3/Vref1 under three different kinds of methods are given. Finally, through the experimental platform, the control effects of the three kinds of SVPWM are compared under two constraint conditions. © 2021 Journal of Northwestern Polytechnical University.
引用
收藏
页码:865 / 875
页数:10
相关论文
共 25 条
  • [1] PIZZO A D, NOIA L P D, PIZZA A., Analysis of a five phase electrical drive for the propulsion of all electric aircraft, 2016 AEIT International Annual Conference, pp. 1-6, (2016)
  • [2] KUANG Z, ZHAO T, CUI S., Five-phase permanent magnet synchronous motor drive for aircraft applications, 2016 UKACC 11th International Conference on Control, pp. 1-6, (2016)
  • [3] TIAN B, MIRZAEVA G, AN Q, Et al., Fault-tolerant control of a five-phase permanent magnet synchronous motor for industry applications, IEEE Trans on Industry Applications, 54, 4, pp. 3943-3952, (2018)
  • [4] QIU L H, YONG C, LI X., Fault-tolerant control strategy for five-phase pmsm with third-harmonic current injection, IEEE Access, 6, pp. 58501-58509, (2018)
  • [5] MEKRI F, BEN ELGHALI S, BENBOUZID M E H., Fault-tolerant control performance comparison of three-and five-phase PMSG for marine current turbine applications, IEEE Trans on Sustain Energy, 4, 2, pp. 425-433, (2013)
  • [6] LOPEZ O., Carrier-based PWM equivalent to multilevel multiphase space vector PWM techniques, IEEE Trans on Industrial Electronics, 67, 7, pp. 5220-5231, (2020)
  • [7] KELLY J W, STRANGAS E G, MILLER J M., Multiphase space vector pulse width modulation, IEEE Trans on Energy Conversion, 18, 2, pp. 259-264, (2003)
  • [8] IQBAL A, LEVI E., Space vector modulation schemes for a five-phase voltage source inverter, 2005 European Conference on Power Electronics and Applications, (2005)
  • [9] Renukadevi G, Rajambal K., Field programmable gate array implementation of space-vector pulse-width modulation technique for five-phase voltage source inverter, IET Power Electronics, 7, 3, pp. 376-389, (2014)
  • [10] WANG K, ZHU Z Q, OMBACH G., Torque improvement of five-phase surface-mounted permanent magnet machine using third-order harmonic, IEEE Trans on Energy Conversion, 29, 3, pp. 735-747, (2014)