Effectiveness of indicator bacteria removal in vertical flow filters filled with natural materials

被引:0
|
作者
Wa&cedil [1 ]
sik E. [1 ]
Chmielowski K. [1 ]
机构
[1] Department of Sanitary Engineering and Water Management, University of Agriculture in Kraków, al. Mickiewicza 24/28, Kraków
来源
Environment Protection Engineering | 2019年 / 45卷 / 02期
关键词
Escherichia coli - Principal component analysis - Zeolites - Sewage;
D O I
10.37190/EPE190206
中图分类号
学科分类号
摘要
The effectiveness of removing indicator bacteria from domestic sewage using a vertical flow filter filled with natural materials has been analysed. The count of Escherichia coli and coliform bacteria was measured in raw and treated sewage and effectiveness of their removal under variable conditions of hydraulic load and depending on the filter filling (type, size and filling proportions) was assessed. A single-layer sand or zeolite filter was the most effective in reducing bacterial contamination. The sand-filled filter allowed the removal of 99.993-99.997% of Escherichia coli and the one filled with fine zeolite of 99.995%. The principal component analysis was used to comprehensively evaluate the filter performance. Three principal components were identified and they were responsible for 81% of raw data variability. The effectiveness of indicator bacteria removal depended mainly on the filling grain size and did not on filling proportions or its type. © 2019 Technical University of Wroclaw. All rights reserved.
引用
收藏
页码:83 / 93
页数:10
相关论文
共 50 条
  • [1] EFFECTIVENESS OF INDICATOR BACTERIA REMOVAL IN VERTICAL FLOW FILTERS FILLED WITH NATURAL MATERIALS
    Wasik, Ewa
    Chmielowski, Krzysztof
    ENVIRONMENT PROTECTION ENGINEERING, 2019, 45 (02): : 83 - 93
  • [2] Ammonia and indicator bacteria removal from domestic sewage in a vertical flow filter filled with plastic material
    Wasik, Ewa
    Chmielowski, Krzysztof
    ECOLOGICAL ENGINEERING, 2017, 106 : 378 - 384
  • [3] Nitrogen Removal in Vertical-Flow Filters Filled with Lightweight Aggregate Made of Fly Ashes and Gravel
    Ostrowska, Kamila
    Janczukowicz, Wojciech
    Bialowiec, Andrzej
    Rodziewicz, Joanna
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2013, 139 (10) : 1266 - 1272
  • [4] Bacteria removal effectiveness of ceramic pot filters not applied with colloidal silver
    Clark, K. N.
    Elmore, A. C.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2011, 11 (06): : 765 - 772
  • [5] Removal of indicator bacteria from municipal wastewater in an experimental two-stage vertical flow constructed wetland system
    Arias, CA
    Cabello, A
    Brix, H
    Johansen, NH
    WATER SCIENCE AND TECHNOLOGY, 2003, 48 (05) : 35 - 41
  • [6] Flow patterns of natural convection in an air-filled vertical cavity
    Wakitani, S
    PHYSICS OF FLUIDS, 1998, 10 (08) : 1924 - 1928
  • [7] Seasonal Variability in Benzene Removal by Vertical-Flow Constructed Wetland Filters
    Xianqiang Tang
    Paul Emeka Eke
    Miklas Scholz
    Suiliang Huang
    Water, Air, and Soil Pollution, 2009, 202 : 259 - 272
  • [8] Seasonal Variability in Benzene Removal by Vertical-Flow Constructed Wetland Filters
    Tang, Xianqiang
    Eke, Paul Emeka
    Scholz, Miklas
    Huang, Suiliang
    WATER AIR AND SOIL POLLUTION, 2009, 202 (1-4): : 259 - 272
  • [9] Flow visualization of natural convection in a tall, air-filled vertical cavity
    Wright, JL
    Jin, H
    Hollands, KGT
    Naylor, D
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (5-6) : 889 - 904
  • [10] Reactive transport simulation of volatile organic compound removal in vertical flow soil filters
    De Biase, Cecilia
    Maier, Uli
    Oswald, Sascha
    Thullner, Martin
    MODELS - REPOSITORIES OF KNOWLEDGE, 2012, 355 : 169 - +