An online calculation data generation technology for a power grid integrated with a large-scale wind farm

被引:0
|
作者
Bai S. [1 ]
Yan M. [2 ,3 ]
Xu W. [2 ,3 ]
Meng J. [1 ]
Sun X. [1 ]
Zhou H. [2 ,3 ]
机构
[1] State Grid Ningxia Electric Power Co., Ltd., Yinchuan
[2] NARI Technology Co., Ltd., Nanjing
[3] NARI Group Co., Ltd., Nanjing
关键词
Equivalent wind power generators; Large-scale wind power; Low voltage network status identification; Multi-source data fusion; Online calculation;
D O I
10.19783/j.cnki.pspc.200437
中图分类号
学科分类号
摘要
The large-scale integration of wind farms leads to more complex stability modes. Online security and stability analysis is necessary to improve the new energy absorption capacity and operational efficiency of a power grid. An online calculation data generation technology is proposed to simulate the dynamic characteristics of wind farm accurately. First, the operating state of the low-voltage network is identified by the fusion of multi-source real-time data from state estimation, SCADA and security and stability control systems to form operating mode data integrated with wind farm clusters. A spatio-temporal correlation measurement correction model is adopted to identify and correct bad measurement data unhandled by state estimation. Secondly, a clustering method based on Analytic Hierarchy Process (AHP) is used to obtain a dynamic equivalent model of wind farm based on static characteristics and the operating state of wind turbines. Finally, the effectiveness of the method has been verified by cases of the actual power grid. © 2021, Power System Protection and Control Press. All right reserved.
引用
收藏
页码:66 / 73
页数:7
相关论文
共 23 条
  • [1] ATHARI M H, WANG Z., Impacts of wind power uncertainty on grid vulnerability to cascading overload failures, IEEE Transactions on Sustainable Energy, 9, 1, pp. 128-137, (2018)
  • [2] SUN Yujiao, WU Junling, WANG Yating, Et al., Influence analysis of renewable power resources' integration on transmission capability of northwest to Xinjiang power corridor and system's security and stability, Electric Power Construction, 37, 6, pp. 17-23, (2016)
  • [3] XUE Yusheng, LEI Xing, XUE Feng, Et al., A review on impacts of wind power uncertainties on power systems, Proceedings of the CSEE, 34, 29, pp. 5029-5040, (2014)
  • [4] CHIANG H D, TONG J Z, TADA Y., On-line transient stability screening of 14000-bus models using TEPCO-BCU evaluation and methods, 2010 IEEE PES General Meeting, pp. 1-8, (2010)
  • [5] SUN Shuming, XIE Chang, LU Ying, Et al., Power system online security and stability analysis application modes, Power System Technology, 39, 10, pp. 2875-2881, (2015)
  • [6] DING Ping, XU Youping, WANG Jianbo, Et al., Study of the characteristics of grid model for online dynamic security assessment system in bulk power systems, Power System Protection and Control, 41, 19, pp. 132-139, (2013)
  • [7] FANG Yongjie, Discussion on influence of model uncertainties on closed-loop adaptive stability control design, Automation of Electric Power Systems, 35, 16, pp. 49-53, (2011)
  • [8] LIN Li, ZHU Chenchen, ZHENG Taiyi, Et al., Active power control of wind farm cluster and its strategy, Automation of Electric Power Systems, 38, 14, pp. 9-16, (2014)
  • [9] XUE Feng, CHANG Kang, WANG Ningbo, Coordinated control frame of large-scale intermittent power plant cluster, Automation of Electric Power Systems, 35, 22, pp. 45-53, (2011)
  • [10] ZHOU Hongting, XIE Huan, WU Tao, Et al., Analysis and simulation of wind farm dynamic behavior in high-voltage trip-off accident of Zhangbei, Electric Power Automation Equipment, 37, 2, pp. 54-60, (2017)