Axial force of CFT column and steel column embedded into cast-in-place concrete pile were measured in top-down construction method. In addition, measurement results were accurately simulated by FEM analysis. Axial force transfer mechanism from CFT column to pile is analyzed according to field measurement and FEM analysis results. At the pile head, axial force of concrete transferred from steel column is increasing and becomes stable due to slipping between steel column and concrete. Besides, it was found that shear strength of stud connectors at the pile head are 60% of design shear strength. © 2021 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:668 / 673
页数:5
相关论文
共 50 条
  • [1] Field study of reactions of rigid pile composite foundation for high-rise building
    Guo, Zhong-Xian
    Wang, Zhan-Lei
    Yang, Zhi-Hong
    Yantu Lixue/Rock and Soil Mechanics, 2009, 30 (01): : 163 - 168
  • [2] Study on High-rise Building Transfer Floor
    Wang, Bin
    Yang, Huiqin
    Zhang, Wenxin
    SMART MATERIALS AND INTELLIGENT SYSTEMS, PTS 1 AND 2, 2011, 143-144 : 857 - 862
  • [3] Study on column-pile connections of a high-rise over-track building with no footing beams
    Kato, Satoshi
    Takada, Keiichi
    Ishibashi, Teruki
    Hasuda, Tsuneo
    Sumitomo Metals, 1991, 43 (07): : 92 - 103
  • [4] Force Analysis on High-rise Building with a Transfer Story Stress Under Seismic Action
    Liu, Yingli
    Yan, Teliang
    Li, Jianfei
    Jiang, Zhen
    MATERIALS SCIENCE AND ENGINEERING, PTS 1-2, 2011, 179-180 : 398 - 402
  • [5] Field Monitoring of Column Shortenings in a High-Rise Building during Construction
    Choi, Se Woon
    Kim, Yousok
    Kim, Jong Moon
    Park, Hyo Seon
    SENSORS, 2013, 13 (11): : 14321 - 14338
  • [6] Optical fiber monitoring of the column axial force of high-rise buildings during construction
    Nishizawa, Takao
    Ohno, Tomio
    Tobita, Jun
    Fukuwa, Nobuo
    AIJ Journal of Technology and Design, 2009, 15 (31) : 751 - 756
  • [7] ELASTO-PLASTIC SEISMIC RESPONSE ANALYSIS OF HIGH-RISE BUILDING IN CONSIDERATION OF FLUCTUATION OF AXIAL FORCE ON CFT COLUMNS (PART 1): ANALYTICAL METHOD AND EXPERIMENTAL SIMULATION ANALYSIS OF SQUARE CFT COLUMNS
    Hiraki, Tatsuya
    Isozaki, Yutaka
    Journal of Structural and Construction Engineering, 89 (823): : 947 - 954
  • [8] Analysis method for internal force of pile foundation of complex high-rise buildings
    Teng, Yan-Jing
    Shi, Jin-Long
    Gong, Jian-Fei
    Wang, Shu-Guang
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2013, 35 (SUPPL.2): : 1138 - 1142
  • [9] Axial force transfer mechanism from steel column to reinforced concrete pile
    Sugimoto, Kuniyoshi
    Tsuda, Kazuaki
    Wada, Yasuhiro
    Gokan, Shokichi
    Journal of Structural and Construction Engineering, 2008, 73 (630): : 1393 - 1399
  • [10] Experimental and numerical study on a high-rise building with transfer slab
    Zhang, Jiajun
    Liu, Yanhui
    Zheng, Wenzhi
    JOURNAL OF BUILDING ENGINEERING, 2024, 82