Unbalanced Voltage Based Protection Method for Inter-turn Short-circuit Fault of Phase-controlled Reactor

被引:0
|
作者
Chen H. [1 ]
Huang X. [1 ]
Zhang L. [1 ]
Zhou Q. [1 ]
Li C. [1 ]
机构
[1] NR Electric Co., Ltd., Nanjing
关键词
Differential protection; Inter-turn short-circuit protection; Phase-controlled reactor; Trigger angle; Unbalanced voltage;
D O I
10.7500/AEPS20201013005
中图分类号
学科分类号
摘要
Phase-controlled reactor belongs to dry-type air-core reactor in structure. During operation, its current will change with phase control trigger angle, and its equivalent impedance also changes. The inter-turn short-circuit protection of the conventional dry-type air-core reactor is designed and implemented for the constant impedance reactor, which is not suitable for phase-controlled reactor. This paper presents an inter-turn short-circuit fault protection method for the phase-controlled reactor. First, according to the wiring and working characteristics of phase-controlled reactors, the unbalanced voltage between the two reactors is obtained. Then, the unbalanced current is calculated by sliding data window integration. Finally, based on the principle of differential protection, the judgment of inter-turn short-circuit fault is realized. The proposed method eliminates the influence of thyristor trigger angle on inter-turn short-circuit fault criterion. Real-time digital simulation results based on actual engineering parameters verify the effectiveness of the proposed method. © 2021 Automation of Electric Power Systems Press.
引用
收藏
页码:158 / 164
页数:6
相关论文
共 21 条
  • [1] HUANG Xinbo, ZHANG Long, ZHU Yongcan, Et al., On-line monitoring technology of inter-turn short circuit fault of dry-type air-core reactor, Electric Power Automation Equipment, 39, 2, pp. 143-148, (2019)
  • [2] NIE Hongyan, WEI Xinlao, YAO Yuanhang, Et al., Effect of thermal aging on the characteristic to withstand switching overvoltage of interturn insulation of dry-type air core power reactor, Transactions of China Electrotechnical Society, 35, 24, pp. 1-9, (2020)
  • [3] DUAN Hao, XU Bingyin, WU Shouyuan, Et al., Analysis of the third harmonic current at the fault state of thyristor controlled reactors, Automation of Electric Power Systems, 35, 23, pp. 64-69, (2011)
  • [4] ZHAO Ruoyu, MA Hongzhong, WEI Xu, Et al., Research on fault diagnosis of a high voltage shunt reactor based on EWT and multiscale spectral spectrum, Power System Protection and Control, 48, 17, pp. 64-69, (2020)
  • [5] YIN Ruihan, DING Guocheng, YANG Haitao, Et al., Study on inter-turn short circuit fault detection of dry-type air-core reactor based on power factor method, Power Capacitor & Reactive Power Compensation, 41, 2, pp. 80-85, (2020)
  • [6] GUO Zhe, GUO Zhiguang, JIA Genmao, Et al., Three-stage characteristic analysis on inter-turn fault and comprehensive protection method for air-core shunt reactor, Automation of Electric Power Systems, 44, 8, pp. 149-156, (2020)
  • [7] ZHENG Zong'an, Research and application of fault detection of reactor turn-to-turn short circuit based on magnetic field detection method, High Voltage Apparatus, 56, 3, pp. 217-223, (2020)
  • [8] SONG Han, ZOU Liang, ZHANG Xiuqun, Et al., Inter-turn short-circuit detection of dry-type air-core reactor based on spatial magnetic field distribution, Transactions of China Electrotechnical Society, 34, pp. 105-117, (2019)
  • [9] LIU Xiaoxiao, ZHENG Tao, HUANG Ting, Protection scheme based on the identification of equivalent leakage inductance against turn-to-turn fault of magnetically controlled shunt reactor, Transactions of China Electrotechnical Society, 35, 1, pp. 134-145, (2020)
  • [10] BI Daqiang, WANG Xiangheng, WANG Weijian, Measured impedance based shunt reactor protection against small inter-turn fault, Automation of Electric Power Systems, 29, 3, pp. 57-60, (2005)