Comparison between mathematical methods to estimate blood glucose levels from ECG signals

被引:0
|
作者
Coronado Reyes O.I. [1 ]
Téllez Anguiano A.D.C. [1 ]
Gutiérrez Gnecchi J.A. [1 ]
Castro Pimentel L.A. [1 ]
García Rodríguez E. [1 ]
机构
[1] DEPI, TecNM/Instituto Tecnológico de Morelia, Av. Tecnológico 1500, Col. Lomas de Santiaguito, Michoacán, Morelia
来源
关键词
Blood glucose concentration; Clarke error grid; Cubic regression; Diabetes; Electrocardiogram; Generalized linear model; Linear regression; Quadratic regression;
D O I
10.1016/j.biosx.2024.100474
中图分类号
学科分类号
摘要
Diabetes mellitus, known as diabetes, is a chronic disease that affects the control of blood glucose concentration levels, it is a disease that mostly affects adults (type 2 diabetes), but it can also occur in children (type 1 or childhood diabetes), as well as in pregnant women (gestational diabetes). Diabetes is one of the diseases with the highest prevalence and high mortality worldwide. Diabetes has no cure, but continuous monitoring to maintain blood glucose levels in normal ranges reduces the possibility of suffering from gastrointestinal problems, vision loss, limb amputations (such as diabetic foot) and damage to vital organs such as the heart and kidneys, among other associated complications. This article compares the results in glucose estimation by using a linear, quadratic and cubic regression considering the electrical characteristics generated in the cardiac conduction (HR, HRV, T-wave peak, and QT interval) recorded on a single-lead electrocardiogram (VII), used as a non-invasive blood glucose estimation model. The best estimate was obtained using a cubic regression. The validation was performed using the Clarke grid having 77.78 % of data in the A zone and 22.22 % in the B zone and a Pearson correlation value of 0.94103 in the cubic regression. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [1] High accuracy blood glucose monitoring based on ECG signals
    Li T.
    Ye S.
    Li J.-Z.
    Ma J.-J.
    Lu Y.-P.
    Hong P.-T.
    Nie Z.-D.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2021, 43 (09): : 1215 - 1223
  • [2] Comparison of wavelet thresholding methods for denoising ECG signals
    Cherkassky, V
    Kilts, S
    ARTIFICIAL NEURAL NETWORKS-ICANN 2001, PROCEEDINGS, 2001, 2130 : 625 - 629
  • [3] Classification of Drivers' Mental Workload Levels: Comparison of Machine Learning Methods Based on ECG and Infrared Thermal Signals
    Cardone, Daniela
    Perpetuini, David
    Filippini, Chiara
    Mancini, Lorenza
    Nocco, Sergio
    Tritto, Michele
    Rinella, Sergio
    Giacobbe, Alberto
    Fallica, Giorgio
    Ricci, Fabrizio
    Gallina, Sabina
    Merla, Arcangelo
    SENSORS, 2022, 22 (19)
  • [4] METHODS TO EXTRACT RESPIRATION INFORMATION FROM ECG SIGNALS
    Ruangsuwana, R.
    Velikic, G.
    Bocko, M.
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 570 - 573
  • [5] Mathematical and informational tools for classifying blood glucose signals - a pilot study
    Amadio, Ariel
    Rey, Andrea
    Legnani, Walter
    Garcia Blesa, Manuel
    Bonini, Cristian
    Otero, Dino
    PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2023, 626
  • [6] Blood and tissue glucose level in critically ill patients: a comparison of different methods of measuring interstitial glucose levels
    Vlkova, Andrea
    Dostal, Pavel
    Musil, Frantisek
    Smahelova, Alena
    Zadak, Zdenek
    Cerny, Vladimir
    INTENSIVE CARE MEDICINE, 2009, 35 (07) : 1318 - 1318
  • [7] Blood and tissue glucose level in critically ill patients: a comparison of different methods of measuring interstitial glucose levels
    Andrea Vlkova
    Pavel Dostal
    Frantisek Musil
    Alena Smahelová
    Zdenek Zadak
    Vladimir Cerny
    Intensive Care Medicine, 2009, 35 : 1318 - 1318
  • [8] COMPARISON OF METHODS FOR BLOOD-GLUCOSE MONITORING
    REEVES, ML
    FORHAN, SE
    SKYLER, JS
    PETERSON, CM
    DIABETES CARE, 1981, 4 (03) : 404 - 406
  • [9] COMPARISON OF AUTOANALYZER METHODS FOR ESTIMATION OF GLUCOSE IN BLOOD
    PENNOCK, CA
    MURPHY, D
    SELLERS, J
    LONGDON, KJ
    CLINICA CHIMICA ACTA, 1973, 48 (02) : 193 - 201
  • [10] COMPARISON OF GLUCOSE BLOOD-PLASMA LEVELS IN RABBITS BY 3 DIFFERENT ASSAY-METHODS
    OH, CK
    RITSCHEL, WA
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1987, 76 (11) : S25 - S25