Performance evaluation of cefoxitin screen test on two different automated antimicrobial susceptibility test systems: a comparative study

被引:0
|
作者
Yuceel-Timur, Ismail [1 ]
Garner, Cherilyn D. [2 ]
Franklin, Simone [2 ]
Hardy, Dwight J. [3 ]
机构
[1] bioMerieux, Global Med Affairs, Lyon, France
[2] bioMerieux, Global Med Affairs, Hazelwood, MO USA
[3] Univ Rochester, Med Ctr, Dept Microbiol & Immunol, Rochester, NY USA
来源
MICROBIOLOGY SPECTRUM | 2024年 / 12卷 / 09期
关键词
VITEK; 2; MRSA; Staphylococcus spp; cefoxitin screen; methicillin-resistant Staphylococcus spp; Phoenix; oxacillin; BD Phoenix; cefoxitin (oxsf02n); MECA-MEDIATED RESISTANCE; STAPHYLOCOCCUS-AUREUS; BD PHOENIX; SURVEILLANCE;
D O I
10.1128/spectrum.03815-23
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Reliable detection of mecA and mecC-mediated beta-lactam resistance using automated antimicrobial susceptibility test systems is critical for patient care. The aim of this study was to compare the performance of the new cefoxitin screen test (oxsf02n) on the Vitek 2 card (Vitek 2) and BD Phoenix PMC-100 Gram-Positive AST Panel (Phoenix) against the reference method for the detection of mecA (and mecC)-mediated beta-lactam resistance. Two hundred fifty clinical fresh and stock Staphylococcus spp. isolates were included. There were 120 mecA-positive, 10 mecC-positive, and 120 mecA and mecC-negative isolates. Cefoxitin screen and oxacillin tests were performed on Vitek 2 and Phoenix and by their respective reference methods (disk diffusion for the cefoxitin screen test and broth microdilution for oxacillin) for all isolates. PCR testing was also performed to confirm the presence of mecA and/or mecC genes. Results from each system were compared to the reference methods. Statistical hypotheses were evaluated both for Vitek 2 compared to the reference methods and Vitek 2 compared to the Phoenix. Compared to the reference method, the Vitek 2 cefoxitin screen test had 100% sensitivity/98% specificity and the Phoenix cefoxitin screen test had 84% sensitivity/100% specificity for the detection of mecA (and mecC)-mediated beta-lactam resistance. When the oxacillin test was combined with the cefoxitin screen for Vitek 2, the sensitivity and specificity were unchanged. However, when the oxacillin and cefoxitin screen tests were combined for the Phoenix, the sensitivity increased to 100% and the specificity remained unchanged (100%). When considering cefoxitin alone, the Vitek 2 screen test showed a higher sensitivity than the Phoenix for the detection of mecA and mecC-mediated beta-lactam resistance. However, currently, both systems use a combination of the cefoxitin and oxacillin tests to interpret the final result, and both reached a high level of performance when cefoxitin and oxacillin results were combined.IMPORTANCEThis research marks the inaugural evaluation of the revamped cefoxitin screen test version in Vitek 2, juxtaposing it against reference methods and a primary competitor BD Phoenix.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF THE BIOGRAM ANTIMICROBIAL SUSCEPTIBILITY TEST SYSTEM
    DAMATO, RF
    HOCHSTEIN, L
    VERNALEO, JR
    CLERI, DJ
    WALLMAN, AA
    GRADUS, MS
    THORNSBERRY, C
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (05) : 793 - 798
  • [2] Automated Evaluation for Performance Test Scripts
    Gao, Ruijing
    Chen, Zhenyu
    Fang, Chunrong
    He, Tieke
    Xie, Peizhang
    Zhou, Jungui
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON SOFTWARE QUALITY, RELIABILITY AND SECURITY COMPANION (QRS-C 2016), 2016, : 135 - 142
  • [3] COLLABORATIVE EVALUATION OF THE UNISCEPT QUALITATIVE ANTIMICROBIAL SUSCEPTIBILITY TEST
    DAMATO, RF
    ISENBERG, HD
    MCKINLEY, GA
    HOCHSTEIN, L
    CLERI, DJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (03) : 293 - 297
  • [4] COLLABORATIVE EVALUATION OF THE UNISCEPT QUANTITATIVE ANTIMICROBIAL SUSCEPTIBILITY TEST
    ISENBERG, HD
    DAMATO, RF
    MCKINLEY, GA
    HOCHSTEIN, L
    SAMPSONSCHERER, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 19 (06) : 733 - 735
  • [5] COMPARATIVE STUDY OF ALGORITHMS USED FOR AUTOMATED EVALUATION OF THE TENSILE TEST RESULTS
    Kana, Josef
    Jenicek, Stepan
    Masek, Bohuslav
    [J]. METAL 2015: 24TH INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, 2015, : 688 - 692
  • [6] COMPARISON OF BIOGRAM AND COMMERCIAL MICRODILUTION ANTIMICROBIAL SUSCEPTIBILITY TEST SYSTEMS
    SAUTTER, RL
    DENYS, GA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (02) : 301 - 304
  • [7] Analytical performance evaluation of different test systems on serum creatinine assay
    He, Lina
    Yu, Jinqi
    Han, Guang
    Huang, Di
    Han, Liqiao
    Zhang, Qiaoxuan
    Wang, Yunxiu
    Wan, Zemin
    Huang, Xian-Zhang
    Xiong, Yujuan
    Wu, Xiaobin
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (02)
  • [8] Automated cover/uncover test: Evaluation of two prototypes
    Apple, HP
    Hartmann, EE
    Miller, JM
    Apple, DC
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U657 - U657
  • [9] Automated laser damage threshold test systems of different test modes for optical elements
    Ma, Bin
    Zhang, Yanyun
    Ma, Hongping
    Liu, Huasong
    Ji, Yiqin
    [J]. LASER-INDUCED DAMAGE IN OPTICAL MATERIALS: 2012, 2012, 8530
  • [10] EVALUATION OF THE E TEST FOR ANTIMICROBIAL SUSCEPTIBILITY TESTING OF ACTINOBACILLUS-ACTINOMYCETEMCOMITANS
    PAJUKANTA, R
    ASIKAINEN, S
    SAARELA, M
    ALALUUSUA, S
    JOUSIMIESSOMER, H
    [J]. ORAL MICROBIOLOGY AND IMMUNOLOGY, 1992, 7 (06): : 376 - 377