Enhanced recognition of insulator defects on power transmission lines via proposal-based detection model with integrated improvement methods

被引:0
|
作者
Wang, Qinglong [1 ,2 ,3 ]
Li, Yongjian [1 ,2 ,3 ]
Cui, Shihao [1 ,2 ,3 ]
Li, Na [1 ,2 ,3 ]
Zhang, Xinchun [1 ,2 ,3 ]
Jiang, Wenqiang [1 ,2 ,3 ]
Peng, Wen [4 ]
Sun, Jie [4 ]
机构
[1] North China Elect Power Univ, Dept Mech Engn, Baoding 071003, Peoples R China
[2] North China Elect Power Univ, Hebei Engn Res Ctr Adv Mfg &Intelligent Operat & M, Baoding 071003, Peoples R China
[3] North China Elect Power Univ, Hebei Key Lab Elect Machinery Hlth Maintenance & F, Baoding 071003, Peoples R China
[4] Northeastern Univ, State Key Lab Rolling & Automat, Shenyang 110819, Peoples R China
基金
中国国家自然科学基金;
关键词
Proposal-based detector; Swin transformer; Power insulator; Defect recognition; Attention mechanism; INSPECTION; CLASSIFICATION;
D O I
10.1016/j.engappai.2024.109078
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Deep learning-driven transmission line inspection is a critical area for smart power grid development. Despite advances in deep learning for insulator defect detection, challenges remain in model robustness and adaptability for the varying real-world adaptability, especially for insignificant defects in complex backgrounds. This study presents a comprehensive improvement strategy for detecting insulators and cross-scale broken defects on transmission lines, employing a proposal-based detection model. The model introduces a holistic pipeline of improved methods, including backbone modification, anchor box scale recalibration, and improvements in Region of Interest (RoI) downsampling alignment and Intersection over Union (IoU) loss function. Various backbone networks, including convolutional network (ConvNet) and Vision Transformer (ViT) structures, are constructed and integrated with attention modules, specifically designed to amplify the perception of insulators and defective regions. The geometric scale of anchor boxes is reconstructed using a developed clustering algorithm, considering the elongated characteristics of insulator strings to improve the adaptability of anchor boxes. Bilinear interpolation is utilized to mitigate spatial misalignment issues during the downsampling process of Region Proposal Network (RPN)-based proposals. The experimental results indicate that the improved models with the Swin Transformer (Swin-T) backbone framework achieve the mean Average Precision (mAP)@0.5 of 88.42% and mAP@0.7 of 60.52%, with a defect recall rate of 81.94%. Additionally, the improved IoU loss function contributes to the performance of the model at higher IoU thresholds. The results of this study contribute to the further development of defect detection frameworks for power vision applications.
引用
收藏
页数:16
相关论文
共 13 条
  • [1] An improved transfer learning model for detection of insulator defects in power transmission lines
    Pradeep, V.
    Baskaran, K.
    Evangeline, S. Ida
    Neural Computing and Applications, 2025, 37 (09) : 6951 - 6976
  • [2] An Insulator in Transmission Lines Recognition and Fault Detection Model Based on Improved Faster RCNN
    Zhao, Wenqing
    Xu, Minfu
    Cheng, Xingfu
    Zhao, Zhenbing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [3] A Deep Learning Based Detection Method for Insulator Defects in High Voltage Transmission Lines
    Tingyu, Wang
    Xia, Sun
    Jiaxing, Liu
    Yue, Zhang
    International Journal of Advanced Computer Science and Applications, 2024, 15 (10) : 378 - 384
  • [4] Deep learning based insulator fault detection algorithm for power transmission lines
    Wang, Han
    Yang, Qing
    Zhang, Binlin
    Gao, Dexin
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2024, 21 (04)
  • [5] Detection of Transmission Line Insulator Defects Based on an Improved Lightweight YOLOv4 Model
    Qiu, Zhibin
    Zhu, Xuan
    Liao, Caibo
    Shi, Dazhai
    Qu, Wenqian
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [6] Detection of the Pin Defects of Power Transmission Lines Based on Improved TPH-MobileNetv3
    Li, Mengxuan
    Han, Jingshan
    Yang, Zhi
    Zhao, Bin
    Liu, Peng
    JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2023, 2023
  • [7] Detection of partial discharge patterns in hybrid high voltage power transmission lines based on parallel recognition method
    Yang, Yang
    Wu, Yongye
    Gao, Yifei
    Huang, Yixuan
    Liu, Shukun
    Wang, Yuanshi
    PEERJ COMPUTER SCIENCE, 2024, 10
  • [8] Detection of partial discharge patterns in hybrid high voltage power transmission lines based on parallel recognition method
    Yang Y.
    Wu Y.
    Gao Y.
    Huang Y.
    Liu S.
    Wang Y.
    PeerJ Computer Science, 2024, 10
  • [9] Insulator Faults Detection in Aerial Images from High-Voltage Transmission Lines Based on Deep Learning Model
    Liu, Chuanyang
    Wu, Yiquan
    Liu, Jingjing
    Sun, Zuo
    Xu, Huajie
    APPLIED SCIENCES-BASEL, 2021, 11 (10):
  • [10] POWER TRANSMISSION TOWER CFAR DETECTION ALGORITHM BASED ON INTEGRATED SUPERPIXEL WINDOW AND ADAPTIVE STATISTICAL MODEL
    Zhou, Xin
    Liu, Xiuguo
    Chen, Qihao
    Zhang, Zhengjia
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 2326 - 2329