Multiphase Flow's Volume Fractions Intelligent Measurement by a Compound Method Employing Cesium-137, Photon Attenuation Sensor, and Capacitance-Based Sensor

被引:1
|
作者
Mayet, Abdulilah Mohammad [1 ]
Fouladinia, Farhad [2 ]
Hanus, Robert [2 ]
Parayangat, Muneer [1 ]
Raja, M. Ramkumar [1 ]
Muqeet, Mohammed Abdul [1 ]
Mohammed, Salman Arafath [1 ]
机构
[1] King Khalid Univ, Fac Engn, Elect Engn Dept, Abha 61411, Saudi Arabia
[2] Rzeszow Univ Technol, Fac Elect & Comp Engn, Rzeszow, Poland
关键词
capacitance-based sensor; photon attenuation sensor; ANN; volume fraction; measuring system; multiphase homogeneous fluid; 3-PHASE FLOW; PREDICTION; ALGORITHM; DERIVATIVES; REGIME;
D O I
10.3390/en17143519
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Multiphase fluids are common in many industries, such as oil and petrochemical, and volume fraction measurement of their phases is a vital subject. Hence, there are lots of scientists and researchers who have introduced many methods and equipment in this regard, for example, photon attenuation sensors, capacitance-based sensors, and so on. These approaches are non-invasive and for this reason, are very popular and widely used. In addition, nowadays, artificial neural networks (ANN) are very attractive in a lot of fields and this is because of their accuracy. Therefore, in this paper, to estimate volume proportion of a three-phase homogeneous fluid, a new system is proposed that contains an MLP ANN, standing for multilayer perceptron artificial neural network, a capacitance-based sensor, and a photon attenuation sensor. Through computational methods, capacities and mass attenuation coefficients are obtained, which act as inputs for the proposed network. All of these inputs were divided randomly in two main groups to train and test the presented model. To opt for a suitable network with the lowest rate of mean absolute error (MAE), a number of architectures with different factors were tested in MATLAB software R2023b. After receiving MAEs equal to 0.29, 1.60, and 1.67 for the water, gas, and oil phases, respectively, the network was chosen to be presented in the paper. Hence, based on outcomes, the proposed approach's novelty is being able to predict all phases of a homogeneous flow with very low error.
引用
收藏
页数:20
相关论文
共 2 条
  • [1] Performance comparison of capacitance-based flowmeter with gamma-ray attenuation-based two-phase flowmeter for determining volume fractions in an annular flow regime’s components
    Mohammadmehdi Roshani
    Giang T. T. Phan
    Ehsan Nazemi
    Ehsan Eftekhari-Zadeh
    Nhut-Huan Phan
    Enrico Corniani
    Hoai-Nam Tran
    Van Hao Duong
    Gholam Hossein Roshani
    The European Physical Journal Plus, 136
  • [2] Performance comparison of capacitance-based flowmeter with gamma-ray attenuation-based two-phase flowmeter for determining volume fractions in an annular flow regime's components
    Roshani, Mohammadmehdi
    Phan, Giang T. T.
    Nazemi, Ehsan
    Eftekhari-Zadeh, Ehsan
    Nhut-Huan Phan
    Corniani, Enrico
    Hoai-Nam Tran
    Van Hao Duong
    Roshani, Gholam Hossein
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (02):