Wear Assessment of Novel PEEK Telescopic Attachment for Implant-Retained Mandibular Overdenture: A Clinical Trial Study

被引:0
|
作者
Quassem, Mohamed A. [1 ]
Badr, Wesam E. [1 ]
Mansour, Mamdouh M. [1 ]
Mahross, Hamada Z. [1 ,2 ]
机构
[1] Al Azhar Univ, Fac Dent Med, Removable Prosthodont Dept, Cairo, Egypt
[2] Buraydah Private Coll, Coll Dent & Pharm, Dept Substitut Dent Sci, Buraydah 51418, Saudi Arabia
来源
OPEN DENTISTRY JOURNAL | 2024年 / 18卷
关键词
Peek; Telescopic attachment; Attachment wear; Zirconia; POLYETHERETHERKETONE PEEK; FORCE; RESTORATIONS; FABRICATION; COMPOSITES; MANAGEMENT; RETENTION; POLYMER; SYSTEM; CROWNS;
D O I
10.2174/0118742106317120240916074959
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The wear of Zirconia-PEEK telescopic attachments can affect the retention of the implant-retained complete mandibular overdenture. Aims: This study aimedto assess Zirconia-PEEK wear versus cobalt-chromium-PEEK telescopic attachments for the implant-retained complete mandibular overdenture. Methods: Twelve completely edentulous patients were randomly chosen for implant-retained telescopic overdentures construction and divided into two groups, where group I was a patient with zirconia copies, and group II was with a cobalt-chromium CoCr copy. The PEEK was constructed for both groups as a secondary coping telescopic attachment for the denture. The wear measurements of PEEK were performed optically by using a USB digital microscope with a built-in camera connected to a compatible personal computer at different intervals of baseline, 3, 6, and 9 months. The data were statistically analyzed and compared using Student t-test, ANOVA, and Post Hoc Test. Results: The statistical data revealed that groups II and I, in comparison, showed a non-significant difference in topographic features (RMS) of PEEK at different intervals of baseline, 3, 6, and 9 months. Conclusion: Within the limitations of the study, there was no significant difference between combining Zirconia-PEEK or CoCr-PEEK for telescopic overdenture procedures. Therefore, it is advisable esthetically and biomechanically to apply Zirconia-PEEK procedures instead of CoCr-PEEK to produce metal-free dental telescopic overdenture.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Mandibular implant-retained overdenture: A clinical trial of two anchorage systems
    Menicucci, G
    Lorenzetti, M
    Pera, P
    Preti, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (06) : 851 - 856
  • [2] In vitro assessment of polyetheretherketone for an attachment component for an implant-retained overdenture
    da Silva, Geyson Galo
    Wada Shimano, Marcos Vinicius
    Macedo, Ana Paula
    da Costa Valente, Mariana Lima
    dos Reis, Andrea Candido
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 319.e1 - 319.e8
  • [3] Dental implant-retained mandibular overdenture therapy: A clinical study of patients' response
    Pan, Yu-Hwa
    Yu, Ling-Ming
    Lin, Tai-Min
    JOURNAL OF DENTAL SCIENCES, 2014, 9 (02) : 118 - 124
  • [4] Fabrication of a mandibular implant-retained overdenture using an existing subperiosteal implant: A clinical report
    Arshad, Mahnaz
    Khoramshahi, Nourin
    Shirani, Gholamreza
    CLINICAL CASE REPORTS, 2024, 12 (04):
  • [5] THE SERVICE LIFE OF IMPLANT-RETAINED OVERDENTURE ATTACHMENT SYSTEMS
    Pigozzo, Monica Nogueira
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    Vaz, Luis Geraldo
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (02): : 74 - 80
  • [6] Biomechanical rationale for a single implant-retained mandibular overdenture:: an in vitro study
    Maeda, Yoshinobu
    Horisaka, Mitsuhiro
    Yagi, Kaztomo
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 271 - 275
  • [7] WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL
    Buettel, Adrian E.
    Luethy, Heinz
    Sendi, Pedram
    Marinello, Carlo P.
    JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (02): : 109 - 113
  • [8] The effect of attachment type and implant number on satisfaction and quality of life of mandibular implant-retained overdenture wearers
    Mumcu, Emre
    Bilhan, Hakan
    Geckili, Onur
    GERODONTOLOGY, 2012, 29 (02) : E618 - E623
  • [9] RADIOGRAPHIC AND SURGICAL GUIDE FABRICATION FOR IMPLANT-RETAINED MANDIBULAR OVERDENTURE
    Wulfman, Claudine
    Hadida, Alain
    Rignon-Bret, Christophe
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (01): : 53 - 57
  • [10] An alternative approach for the management of fractured implant abutment screws on a mandibular implant-retained overdenture: A clinical report
    Shah, Karnik
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (04): : 402 - 405