Diagnostic accuracy of the Brief Assessment of Impaired Cognition case-finding instrument in a general practice setting and comparison with other widely used brief cognitive tests-a cross-validation study

被引:0
|
作者
Jorgensen, Kasper [1 ]
Nielsen, T. Rune [1 ,2 ]
Nielsen, Ann [1 ]
Oxboll, Anne-Britt [1 ]
Gerner, Sofie D. [3 ]
Waldorff, Frans B. [3 ]
Waldemar, Gunhild [1 ,4 ]
机构
[1] Copenhagen Univ Hosp, Danish Dementia Res Ctr, Dept Neurol, Rigshosp, Copenhagen, Denmark
[2] Univ Copenhagen, Dept Psychol, Copenhagen, Denmark
[3] Univ Copenhagen, Dept Publ Hlth, Sect Gen Practice, Copenhagen, Denmark
[4] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
cognitive dysfunction; dementia; general practice; memory disorders; mental status and dementia tests; FUNCTIONAL-ACTIVITIES; OLDER-ADULTS; DEMENTIA; SENSITIVITY; VALIDITY; DECLINE; DISEASE; RUDAS; SCALE; MOCA;
D O I
10.1111/ene.16418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose: The aim of this study was to examine the discriminative validity of the Brief Assessment of Impaired Cognition (BASIC) case-finding instrument in a general practice (GP) setting and compare it with other widely used brief cognitive instruments. Methods: Patients aged >= 70 years were prospectively recruited from 14 Danish GP clinics. Participants were classified as having either normal cognition (n = 154) or cognitive impairment (n = 101) based on neuropsychological test performance, reported instrumental activities of daily living, and concern regarding memory decline. Comparisons involved the Mini-Mental State Examination (MMSE), the Montreal Cognitive Assessment (MoCA), the Rowland Universal Dementia Assessment Scale (RUDAS), the Mini-Cog, the 6-item Clock Drawing Test (CDT-6) and the BASIC Questionnaire (BASIC-Q). Results: BASIC demonstrated good overall classification accuracy with an area under the receiver operating characteristic curve (AUC) of 0.88 (95% confidence interval [CI] 0.84-0.92), a sensitivity of 0.72 (95% CI 0.62-0.80) and a specificity of 0.86 (95% CI 0.79-0.91). Pairwise comparisons of the AUCs of BASIC, MMSE, MoCA and RUDAS produced non-significant results, but BASIC had significantly higher classification accuracy than Mini-Cog, BASIC-Q and CDT-6. Depending on the pretest probability of cognitive impairment, the positive predictive validity of BASIC varied from 0.83 to 0.36, and the negative predictive validity from 0.97 to 0.76. Conclusions: BASIC demonstrated good discriminative validity in a GP setting. The classification accuracy of BASIC is equivalent to more complex, time-consuming instruments, such as the MMSE, MoCA and RUDAS, and higher than very brief instruments, such as the CDT-6, Mini-Cog and BASIC-Q.
引用
收藏
页数:10
相关论文
共 1 条
  • [1] Brief Assessment of Impaired Cognition (BASIC)-Validation of a new dementia case-finding instrument integrating cognitive assessment with patient and informant report
    Jorgensen, Kasper
    Nielsen, T. Rune
    Nielsen, Ann
    Waldorff, Frans Boch
    Hogh, Peter
    Jakobsen, Soren
    Gottrup, Hanne
    Vestergaard, Karsten
    Waldemar, Gunhild
    INTERNATIONAL JOURNAL OF GERIATRIC PSYCHIATRY, 2019, 34 (11) : 1724 - 1733