Scaling effects on peak wind load estimation for low-rise buildings: An experimental and analytical study

被引:0
|
作者
Moravej, Mohammadtaghi [1 ]
Estephan, Johnny [2 ]
Irwin, Peter [3 ]
Chowdhury, Arindam Gan [2 ,3 ]
机构
[1] Walker Consultants, 707 Wilshire Blvd,Suite 3650, Los Angeles, CA USA
[2] Florida Int Univ, Dept Civil & Environm Engn, Miami, FL 33199 USA
[3] Florida Int Univ, Extreme Events Inst, Int Hurricane Res Ctr, Miami, FL USA
基金
美国国家科学基金会;
关键词
Scaling effects; Large-scale tests; Partial turbulence simulation; Peak wind loads; Low-rise buildings; TECH FIELD EXPERIMENTS; PRESSURE-FLUCTUATIONS; MODEL; SIMULATION; ROOF;
D O I
10.1016/j.engstruct.2024.118499
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Though scaling effects on estimation of peak wind loads are extensively documented in the literature, there is a lack of systematic comparison of such scaling effects across different model scales tested in wind tunnels. Moreover, the limited studies on large-scale physical models accepted the inadequacy of simulating the large turbulent eddies rather than addressing the missing low-frequency turbulence simulation inherent in such largescale testing. This study provides an in-depth comparison of estimates of peak wind loads obtained using a range of experimental scaled models (1:100 and 1:6 model scales) of the Wind Engineering Research Field Laboratory (WERFL) building while applying a Partial Turbulence Simulation (PTS) methodology to incorporate the effects of turbulence. Large-scale wind tunnel testing of structures provides the advantage of achieving an improved Reynolds number (Re) similarity, more accurate geometric similarity, and enhanced resolution of flow details such as corner vortices, than is possible with the use of smaller model scales. However, as the model scale increases, achieving turbulence similarity becomes challenging due to limitations in simulating the low-frequency turbulent eddies in the wind tunnel. The PTS method has been used in the recent past to account for the lowfrequency turbulence effects in the peak wind load estimation. The method is referred to as 1DPTS when considering longitudinal turbulence components only and 2DPTS when considering both longitudinal and lateral turbulence components in the analysis. The computationally intensive 2DPTS can be further simplified by using a weighted average method as described in this paper as "weighted average PTS." The current study explores the effect of scaling on peak wind load estimation by using the 1DPTS, 2DPTS, and weighted average PTS methods. Results from the multi-scale experimental tests demonstrate that using larger model scales and compensating for the low-frequency turbulence deficit in the post-test analysis significantly improve the agreement with the prototype data owing to the simulation of a higher Reynolds number. Furthermore, comparing the results of the proposed weighted average method with full-scale data reveals its potential as a substitute for the original 2DPTS method, offering enhanced accuracy, particularly at the roof corner for oblique wind directions. While the effects of Re are well known, the findings of this study explore its impact in conjunction with the application of the PTS methods on peak Cp estimation across five different model scales with Re ranging from 3.65 x 104 to 2.43 x 106, the latter being closest to the full-scale (field) Re. The findings provide new insights into how large-scale physical model testing in high Re flows, supported by analytical PTS-based compensation, can enhance the accuracy of peak wind load estimations for critical scenarios including cornering winds that generate conical vortices.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Wind Tunnel Test Study of Estimation Method on Peak Wind Pressure of Low-Rise Buildings
    Duan, Min
    Wang, Jiaqi
    Wang, Xiuzhen
    Li, Pingshi
    [J]. MATERIALS SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY, PTS 1 AND 2, 2014, 488-489 : 813 - 816
  • [2] Experimental study on wind load characteristics of low-rise buildings under downburst
    Wang, Zhisong
    Chen, Yuanyuan
    Fang, Zhiyuan
    Deng, Jun
    [J]. Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2019, 47 (09): : 120 - 126
  • [3] AN APPROACH TO THE DETERMINATION OF WIND LOAD EFFECTS ON LOW-RISE BUILDINGS
    HOLMES, JD
    BEST, RJ
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1981, 7 (03) : 273 - 287
  • [4] A numerical study on load effects of low-rise buildings in a wind-blown sand environment
    Hu, Di
    Zhang, Jie
    Pakzad, Rezaali
    Huang, Ning
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [5] Study on the sandstorm load of low-rise buildings via wind tunnel testing
    Huang, Bin
    Li, Zhengnong
    Gong, Bo
    Zhang, Zhitian
    Shan, Bo
    Pu, Ou
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 65
  • [6] Determination of peak factor for wind pressures onv low-rise buildings
    Lakshmanan, N.
    Arunachalam, S.
    Selvi Rajan, S.
    Shanmugasundaram, J.
    [J]. Journal of the Institution of Engineers (India): Civil Engineering Division, 2002, 83 (JUN.): : 32 - 38
  • [7] Experimental study of wind loads on gable roofs of low-rise buildings with overhangs
    Peng Huang
    Ling Tao
    Ming Gu
    Yong Quan
    [J]. Frontiers of Structural and Civil Engineering, 2018, 12 : 300 - 317
  • [8] Experimental study of wind loads on gable roofs of low-rise buildings with overhangs
    Huang, Peng
    Tao, Ling
    Gu, Ming
    Quan, Yong
    [J]. FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2018, 12 (03) : 300 - 317
  • [9] Experimental Study of Wind Pressures on Low-Rise H-Shaped Buildings
    Medinilha-Carvalho, Talita Andrioli
    da Silva, Fernando Vitor
    Bre, Facundo
    Gimenez, Juan M.
    Labaki, Lucila Chebel
    [J]. BUILDINGS, 2024, 14 (03)
  • [10] Wind load combinations and extreme pressure distributions on low-rise buildings
    Tamura, Y
    Kikuchi, H
    Hibi, K
    [J]. WIND AND STRUCTURES, 2000, 3 (04) : 279 - 289