The diagnostic value and clinical relevance of high frequency ultrasound and shear wave elastography in systemic sclerosis: an observational monocentric study

被引:0
|
作者
Yu, Shengnan [1 ]
Peng, Haiting [1 ,2 ]
Yang, Xiaoyun [3 ]
Ma, Sha [1 ]
Yu, Juan [1 ]
Zuo, Dachen [1 ]
Li, Fayou [1 ]
Wang, Juan [1 ]
Yang, Yonghong [1 ]
Yin, Zijing [1 ]
Zhao, Weiqing [1 ]
Wang, Jing [1 ]
机构
[1] Kunming Univ Sci & Technol, Peoples Hosp Yunnan Prov 1, Dept Rheumatol & Immunol, Affiliated Hosp, Jinbi Rd 157, Kunming 650032, Yunnan, Peoples R China
[2] Guangxi Med Univ, Guigang Peoples Hosp, Dept Rheumatol & Immunol, Affiliated Hosp 8, Zhongshan Middle Rd 1, Guigang 537100, Guangxi, Peoples R China
[3] Kunming Univ Sci & Technol, Peoples Hosp Yunnan Prov 1, Dept Ultrasound, Affiliated Hosp, Jinbi Rd 157, Kunming 650032, Yunnan, Peoples R China
关键词
Clinical relevance; Diagnosis; High frequency ultrasound; Shear wave elastography; Systemic sclerosis; SKIN THICKNESS SCORE; INVOLVEMENT; TRIALS; QUANTIFICATION; DERMATOLOGY; PREDICTOR; STIFFNESS; CRITERIA;
D O I
10.1007/s10067-024-07145-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To unravel the features of skin involvement in patients with systemic sclerosis (SSc) by high frequency ultrasound (HFU) and shear wave elastography (SWE). To assess the ultrasound capabilities to distinguish SSc patients from healthy controls (HCs). We recruited a cohort of SSc patients in this cross-sectional study. HFU and SWE were used to quantify skin thickness and skin stiffness. Receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic capabilities of ultrasound in SSc. The correlation analysis was used to evaluate the clinical relevance of ultrasound measurements in SSc. 20 consecutive SSc patients and 20 age-, gender- and body mass index-matched HCs were included. The skin thickness and stiffness were significantly greater in SSc patients compared with HCs. Patients with high disease activity had higher skin thickness and stiffness compared with patients with low disease activity. The area under the ROC curve (AUC) of the dorsum of middle fingers assessed by HFU was 0.847 (95% CI, 0.761-0.933). The AUC of the forearms and dorsum of hands assessed by SWE were 0.909 (95% CI, 0.829-0.989) and 0.879 (95% CI, 0.807-0.951). Further, the combined HFU and SWE tests displayed the best diagnostic performance with an AUC of 0.980 (95% CI, 0.939-1.000). A significant positive correlation between the ultrasound measurements and the modified Rodnan skin score (mRSS) was observed. The application of ultrasound can assist with disease diagnosis, it is necessary to develop a standard operating protocol to help with future implementation of ultrasound in SSc.
引用
收藏
页码:3759 / 3769
页数:11
相关论文
共 50 条
  • [1] Role of shear wave elastography ultrasound in patients with systemic sclerosis
    Tumsatan, Panaya
    Uscharapong, Meenut
    Srinakarin, Jiraporn
    Nanagara, Ratanavadee
    Khunkitti, Watcharee
    JOURNAL OF ULTRASOUND, 2022, 25 (03) : 635 - 643
  • [2] Role of shear wave elastography ultrasound in patients with systemic sclerosis
    Panaya Tumsatan
    Meenut Uscharapong
    Jiraporn Srinakarin
    Ratanavadee Nanagara
    Watcharee Khunkitti
    Journal of Ultrasound, 2022, 25 : 635 - 643
  • [3] The value of shear wave elastography in diagnosis and assessment of systemic sclerosis
    Cai, Ruyi
    Lin, Zhuohua
    Xu, Dan
    Sun, Yang
    Cui, Ligang
    Mu, Rong
    RHEUMATOLOGY ADVANCES IN PRACTICE, 2023, 7 (03)
  • [4] QUANTITATIVE ASSESSMENT OF SKIN STIFFNESS USING ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SYSTEMIC SCLEROSIS
    Yang, Yujia
    Qiu, Li
    Wang, Liyun
    Xiang, Xi
    Tang, Yuanjiao
    Li, Haocheng
    Yan, Feng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (04): : 902 - 912
  • [5] Diagnostic Performance of Shear Wave Elastography for Carpal Tunnel Syndrome Combined with High Frequency Ultrasound Imaging
    Nam, Kibo
    Peterson, Shawn M.
    Wessner, Corinne E.
    Machado, Priscilla
    Forsberg, Flemming
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [6] High frequency ultrasound vibrational shear wave elastography for preclinical research
    Civale, J.
    Parasaram, V
    Bamber, J. C.
    Harris, E. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (24):
  • [7] Diagnostic Accuracy of Integrating Ultrasound and Shear Wave Elastography in Assessing Carpal Tunnel Syndrome Severity: a Prospective Observational Study
    El-Maghraby, Ahmed Mohamed
    Almalki, Yassir Edrees
    Basha, Mohammad Abd Alkhalik
    Nada, Mohamad Gamal
    El Ahwany, Fatma
    Alduraibi, Sharifa Khalid
    Alshehri, Shaker Hassan S.
    Aldhilan, Asim S.
    Almushayti, Ziyad A.
    Alduraibi, Alaa K.
    Aboualkheir, Mervat
    Attia, Osama
    Amer, Mona M.
    Basha, Ahmed M. Abdelkhalik
    Eladi, Ibrahim M.
    ORTHOPEDIC RESEARCH AND REVIEWS, 2024, 16 : 111 - 123
  • [8] ULTRA-HIGH-FREQUENCY ULTRASOUND FOR THE EVALUATION OF SKIN INVOLVEMENT IN SYSTEMIC SCLEROSIS: PRELIMINARY RESULTS OF A MONOCENTRIC STUDY
    Ferraioli, Y.
    Fogante, M.
    Benfaremo, D.
    Argalia, G.
    Moroncini, G.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 1000 - 1000
  • [9] The diagnostic value of ultrasound and shear wave elastography in the differentiation of benign and malignant soft tissue tumors
    Ozturk, Mesut
    Selcuk, Mustafa Bekir
    Polat, Ahmet Veysel
    Ozbalci, Aysu Basak
    Baris, Yakup Sancar
    SKELETAL RADIOLOGY, 2020, 49 (11) : 1795 - 1805
  • [10] Diagnostic value of shear wave ultrasound elastography of tibial nerve in patients with diabetic peripheral neuropathy
    Heba R. Ibrahim
    Egyptian Journal of Radiology and Nuclear Medicine, 53