Effect of Bedside Ultrasound-Guided Versus Fluoroscopy-Guided Transvenous Cardiac Temporary Pacing in Children with Bradyarrhythmia

被引:1
|
作者
Wang, Yefeng [1 ]
Zuo, Chao [1 ]
Wang, Xiang [1 ]
Xiao, Yunbin [1 ]
Zeng, Min [1 ]
Yang, Yufan [2 ]
Chen, Zhi [1 ]
机构
[1] Cent South Univ, Hunan Childrens Hosp, Affiliated Childrens Hosp, Dept Cardiol,Xiangya Sch Med, 86 Ziyuan Rd, Changsha 410007, Hunan, Peoples R China
[2] Cent South Univ, Hunan Childrens Hosp, Xiangya Sch Med,Affiliated Childrens Hosp, Dept Pediat Intens Care Unit, 86 Ziyuan Rd, Changsha 410007, Hunan, Peoples R China
关键词
Children; Temporary cardiac pacing; Bradycardia; Ultrasound guided; Bedside; OUTCOMES;
D O I
10.1007/s00246-024-03610-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To compare the efficacy and safety of bedside ultrasound-guided and fluoroscopy-guided transvenous cardiac temporary pacing in the treatment of bradyarrhythmia in children. Children treated by temporary intravenous cardiac pacing from January 2016 to June 2023 in Hunan Provincial Children's Hospital were enrolled, and the characteristics and data of the cases were summarized. Patients were divided into bedside ultrasound-guided group (ultrasound group) and fluoroscopy-guided group (fluoroscopy group) according to the implantation guidance methods. The efficacy, safety, and incidence of complications in children were compared, and follow-up analysis was carried out. A total of 30 children were enrolled, including 18 males and 12 females, with a median age of 5.5 (2.9, 10.0) years and a median weight of 18.7 (12.7, 32.7) kg. The most common primary diseases were fulminant myocarditis (13/30 cases) and congenital high-grade AVB (10/30 cases). Among them, the proportion of congenital high AVB in the fluoroscopy group was significantly higher than that in the ultrasound group, and the difference was statistically significant (p = 0.007). The implantation process was successful in all 30 children. From the time of pacing decision to implantation, the median time of ultrasound group was 56 (30, 60) min and that of fluoroscopy group was 154 (78,180) min, with a statistically significant difference (P < 0.001). A total of 5 cases developed complications. There was no statistically significant difference between the two groups (P > 0.05). Compared with traditional fluoroscopic temporary pacing, bedside ultrasound-guided temporary pacing technology can effectively shorten the operation time and reduce the occurrence of complications and has become a better choice for children's emergency and critical care treatment. The right internal jugular vein is preferred for intravenous implantation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Response to "Effect of Bedside Ultrasound-Guided Versus Fluoroscopy-Guided Transvenous Cardiac Temporary Pacing in Children with Bradyarrhythmia"
    Murtaza, Muzna
    Hanif, Zainab Muhammad
    Sami, Syeda Zuha
    Nazir, Ariba
    Venjhraj, F. N. U.
    PEDIATRIC CARDIOLOGY, 2024, : 227 - 228
  • [2] Reply to the comments on "Effect of Bedside Ultrasound-Guided Versus Fluoroscopy-Guided Transvenous Cardiac Temporary Pacing in Children with Bradyarrhythmia"
    Wang, Yefeng
    Chen, Zhi
    PEDIATRIC CARDIOLOGY, 2024, : 229 - 230
  • [3] Comparison of ultrasound-guided versus fluoroscopy-guided reduction of forearm fractures in children
    Jason T. Gillon
    Michael Gorn
    Matthew Wilkinson
    Emergency Radiology, 2021, 28 : 303 - 307
  • [4] Comparison of ultrasound-guided versus fluoroscopy-guided reduction of forearm fractures in children
    Gillon, Jason T.
    Gorn, Michael
    Wilkinson, Matthew
    EMERGENCY RADIOLOGY, 2021, 28 (02) : 303 - 307
  • [5] Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure
    Ferri, Luca A.
    Farina, Andrea
    Lenatti, Laura
    Ruffa, Franco
    Tiberti, GianLuca
    Piatti, Luigi
    Savonitto, Stefano
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2016, 5 (02) : 125 - 129
  • [6] COMPARISON OF ULTRASOUND-GUIDED VERSUS FLUOROSCOPY-GUIDED ACCESS IN FEMORAL ARTERY CANNULATION FOR CARDIAC PROCEDURES
    Shoemaker, Emma
    Tangri, Apoorva
    Vaz, Igor
    Agarwal, Khushboo
    Silberman, Herschl B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1458 - 1458
  • [7] Echocardiography-guided versus fluoroscopy-guided temporary pacing in the emergency setting: an observational study
    Pinneri, Francesco
    Frea, Simone
    Najd, Kamal
    Panella, Silvana
    Franco, Erica
    Conti, Valentina
    Corgnati, Giuditta
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2013, 14 (03) : 242 - 246
  • [8] Ultrasound-Guided Hip Injections: A Comparative Study With Fluoroscopy-Guided Injections
    Byrd, J. W. Thomas
    Potts, Elizabeth A.
    Allison, Rachel K.
    Jones, Kay S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01): : 42 - 46
  • [9] Ultrasound-guided versus fluoroscopy-guided percutaneous nephrolithotomy: a systematic review and meta-analysis
    Yang, Yu-Hsiang
    Wen, Yu-Ching
    Chen, Kuan-Chou
    Chen, Chiehfeng
    WORLD JOURNAL OF UROLOGY, 2019, 37 (05) : 777 - 788
  • [10] Ultrasound-Guided versus Fluoroscopy-Guided Deep Cervical Plexus Block for the Treatment of Cervicogenic Headache
    Wan, Qing
    Yang, Haiyun
    Li, Xiao
    Lin, Caina
    Ke, Songjian
    Wu, Shaoling
    Ma, Chao
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017