Numerical Study on Mechanical Characteristics of Tower Sections with Main Member Disconnection

被引:0
|
作者
Zheng, Hengwei [1 ]
Wu, Changli [1 ]
Liu, Jinhong [1 ]
Zhong, Lang [1 ]
Li, Kai [1 ]
Yan, Zhitao [1 ]
机构
[1] Chongqing Univ Sci & Technol, Dept Theoret & Appl Mech, Chongqing 401331, Peoples R China
基金
中国国家自然科学基金;
关键词
disconnection joint; tower section; ultimate bearing capacity; slenderness ratio correction factor;
D O I
10.3390/buildings14092998
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Restricted by the existing construction technology, there are a lot of disconnections in the angle steel components of transmission towers. At present, there are more studies on single angle steel or cross bracing, but less on the main member containing disconnection joints. According to the disconnection position in the main member, an upper end disconnection, middle end disconnection, and lower end disconnection were designed in this paper. At the same time, a tower section model of a connected main member and a tower section model of a disconnected main member were established and analyzed by finite element analysis. Considering the loadings acting on transmission towers, the two load conditions of axial loading and tension-compression coupling are set. Considering the loadings acting on transmission towers, the influences of the combination form of the inner and outer steel cladding and the steel cladding area ratio on the ultimate bearing capacity of the main member were studied under 72 groups of different tower sections applied with axial loadings. The influence of the disconnection joints on the stability of the tower section was studied under 24 groups of different tower sections applied with tension and compression coupled loading conditions. Referring to the specifications, the slenderness ratio correction factor formula of the disconnect main member can be derived. The results indicate that when designing the disconnection joint in the main member, it is recommended to choose a middle end disconnection with a steel cladding area ratio of 1.0.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Mechanical Characteristics of the Main Tower of a Polygonal Line Tower Cable-Stayed Bridge
    Li, Yan-feng
    He, Ying
    Bao, Long-sheng
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [2] Study on ultimate bearing capacity of main member in transmission tubular tower leg
    Deng, Hong Zhou
    Huang, Bin
    THIN-WALLED STRUCTURES, 2018, 127 : 51 - 61
  • [3] Numerical study on performance of hybrid mechanical draft wet cooling tower
    Deng, Weipeng
    Sun, Fengzhong
    Chen, Kun
    Zhang, Xiaoyu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [4] Numerical study on hysteretic characteristics of transmission tower K-joints
    Zhang, Jian
    Wu, Guangchen
    Yang, Lidong
    FRONTIERS IN MATERIALS, 2022, 9
  • [5] Numerical Simulation Study on Hysteresis Characteristics of Transmission Tower Bolt Joints
    Li J.-X.
    Wang B.
    Sun J.
    Wang S.-H.
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2020, 41 (11): : 1633 - 1639
  • [6] Numerical Study on The Three-dimensional Thermal Characteristics of Mechanical Draft High-level Water Collecting Cooling Tower
    Long G.
    Zhang G.
    Sun F.
    Chen X.
    Deng W.
    Zhang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (13): : 5078 - 5085
  • [7] Research on the Slip Model of Main Member Bar Connection of Transmission Tower Using Bolts
    Wang, Dehong
    Hou, Shifeng
    Ruan, Yiming
    Li, Wenbin
    Ju, Yanzhong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2025, 25 (01) : 68 - 79
  • [8] Numerical study of biofouling effects on the flow dynamic characteristics of blade sections
    Zhang, Tao
    Min, Shao-song
    Peng, Fei
    ADVANCES IN ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2016, : 199 - 202
  • [9] Vibration characteristics of the Bayon temple main tower, Angkor, Cambodia
    Maeda, T
    Sugiura, Y
    Hirai, T
    Structural Studies, Repairs, and Maintenance of Heritage Architecture IX, 2005, 83 : 255 - 264
  • [10] Numerical simulation of a mechanical ventilation heat supply tower
    Guo, Haifeng
    Zhou, Shanshui
    Zhang, Zhao
    Song, Yanli
    Shang, Shaowen
    Gao, Xiangtao
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2022, 41 (04)