Removal of ceftriaxone and cefotaxime antibiotics from industrial wastewater via complexation with Cu(II)

被引:0
|
作者
Abdel-Kader, Doaa A. [1 ]
Eldean, Adel M. Kamal [1 ]
Abd El-Wahab, Mohamed M. [1 ]
Galal, Mohamed S. [2 ]
Hashem, Elham Y. [1 ]
机构
[1] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
[2] Upper Egypt Pharmaceut UP Pharm, Assiut, Egypt
关键词
Ceftriaxone; Cefotaxime; Copper chloride; UV; FTIR; HPLC; SPECTROPHOTOMETRIC DETERMINATION; CEPHALOSPORIN ANTIBIOTICS; AQUEOUS-SOLUTION; SURFACE-WATER; HONG-KONG; DEGRADATION; PHOTODEGRADATION; TOXICITY; PRODUCTS;
D O I
10.1007/s44211-024-00632-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic method (HPLC) with UV detection is described for determination of ceftriaxone sodium (CFX) and cefotaxime sodium (CFM) content in pharmaceutical industrial wastewater. These methods are based on the detection of these antibiotics via the formation of chelate complexes with Cu(II). The developed Liquid Chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. The removal percentage reached about 100 and 92.1% at pH 7.2 for CFX and CFM, respectively. In UV detection, the removal of the chelating antibiotics were based on forming of chelate complexes with Cu(II) which detected at lambda max = 253 and 244 nm for CFX and CFM, respectively. Linearity, accuracy and precision were found to be acceptable over the concentration range of 5.99-59.86 mu g mL-1 for CFX and 14.33-71.63 mu g mL-1 for CFM. The proposed method can be used for the quality control of industrial wastewater containing CFX and CFM.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Occurrence and removal of antibiotics from industrial wastewater
    Akhil, D.
    Lakshmi, Divya
    Senthil Kumar, P.
    Vo, Dai-Viet N.
    Kartik, A.
    [J]. ENVIRONMENTAL CHEMISTRY LETTERS, 2021, 19 (02) : 1477 - 1507
  • [2] Occurrence and removal of antibiotics from industrial wastewater
    D. Akhil
    Divya Lakshmi
    P. Senthil Kumar
    Dai-Viet N. Vo
    A. Kartik
    [J]. Environmental Chemistry Letters, 2021, 19 : 1477 - 1507
  • [3] Complexation of Cu(II) with cefotaxime in NaCl solution
    E. V. Zhuravlev
    V. G. Alekseev
    M. A. Feofanova
    S. S. Ryasenskii
    [J]. Russian Journal of Inorganic Chemistry, 2016, 61 : 877 - 879
  • [4] Complexation of Cu(II) with cefotaxime in NaCl solution
    Zhuravlev, E. V.
    Alekseev, V. G.
    Feofanova, M. A.
    Ryasenskii, S. S.
    [J]. RUSSIAN JOURNAL OF INORGANIC CHEMISTRY, 2016, 61 (07) : 877 - 879
  • [5] Removal of Cu (II) from Industrial Wastewater Using Mechanically Activated Serpentinite
    Petrounias, Petros
    Rogkala, Aikaterini
    Giannakopoulou, Panagiota P.
    Lampropoulou, Paraskevi
    Koutsovitis, Petros
    Koukouzas, Nikolaos
    Laskaris, Nikolaos
    Pomonis, Panagiotis
    Hatzipanagiotou, Konstantin
    [J]. ENERGIES, 2020, 13 (09)
  • [6] Nitrogen removal via nitrite from industrial wastewater
    不详
    [J]. CLEAN-SOIL AIR WATER, 2008, 36 (5-6) : 414 - 414
  • [7] A Review of Methods for Removal of Ceftriaxone from Wastewater
    Karungamye, Petro
    Rugaika, Anita
    Mtei, Kelvin
    Machunda, Revocatus
    [J]. JOURNAL OF XENOBIOTICS, 2022, 12 (03) : 223 - 235
  • [8] A hybrid membrane process for Cu(II) removal from industrial wastewater - Comparison with a conventional process system
    Flores, V
    Cabassud, C
    [J]. DESALINATION, 1999, 126 (1-3) : 101 - 108
  • [9] Removal of Cefotaxime Antibiotic from Industrial Wasterwater via Forming a Complex with Fe(III)
    Hashem, E. Y.
    El-dean, A. M. Kamal
    Galal, M. S.
    Tolba, M. S.
    [J]. JOURNAL OF WATER CHEMISTRY AND TECHNOLOGY, 2022, 44 (05) : 355 - 361
  • [10] Removal of Cefotaxime Antibiotic from Industrial Wasterwater via Forming a Complex with Fe(III)
    E. Y. Hashem
    M. S. A. M. Kamal El-dean
    M. S. Galal
    [J]. Journal of Water Chemistry and Technology, 2022, 44 : 355 - 361