摘要
The calibration of the ICARUS photo-detection system employs a low power laser diode at 405 nm. The laser pulses are delivered in front of the 360 large area PMTs with a custom optical system, that has been recently upgraded to calibrate all of them in a single run, by replacing an optical switch with a custom optical splitter. The distribution of the PMTs' signal arrival time has a distribution with a resolution better than 1 ns, thus allowing a good determination of the absolute event timing.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] The laser diode calibration system of the ICARUS T600 detector at FNAL
    Bonesini, M.
    Benocci, R.
    Bertoni, R.
    Falcone, A.
    Mazza, R.
    Torti, M.
    Menegolli, A.
    Raselli, G. L.
    Rossella, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (05):
  • [2] Calibration of the ICARUS cryogenic photo-detection system at FNAL
    Bonesini, M.
    Benocci, R.
    Bertoni, R.
    Chatterjee, A.
    Diwan, M.
    Menegolli, A.
    Raselli, G.
    Rossella, M.
    Scarpelli, A.
    Suarez, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [3] The development of the Icarus T600 laser diode calibration system
    Bonesini, M.
    Benocci, R.
    Bertoni, R.
    Cervi, T.
    Mazza, R.
    Menegolli, A.
    Raselli, G.
    Rossella, M.
    Torti, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 261 - 262
  • [4] The trigger system of the ICARUS experiment
    Cocco, A. G.
    Della Pietra, M.
    Di Cicco, A.
    Di Meo, P.
    Ereditato, A.
    Fiorillo, G.
    Parascandolo, P.
    Santorelli, R.
    Trattino, P.
    Baboussinov, B.
    Centro, S.
    Pietropaolo, F.
    Ventura, S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (04) : 2118 - 2123
  • [5] The MINERvA experiment at FNAL
    McFarland, KS
    [J]. EUROPEAN PHYSICAL JOURNAL A, 2005, 24 (Suppl 2): : 187 - 187
  • [6] The SciBooNE Experiment at FNAL
    Kurimoto, Y.
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 188 : 182 - 184
  • [7] The MINERνA experiment at FNAL
    Kevin S. McFarland
    [J]. The European Physical Journal A - Hadrons and Nuclei, 2005, 24 : 187 - 187
  • [8] Upgraded DAQ system for the HyperCP experiment
    White, CG
    Jones, TD
    Luebke, WR
    Chen, YC
    Cheng, KC
    Choong, WS
    Kaplan, DM
    Nelson, K
    Rubin, HA
    Turko, B
    Zyla, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 474 (01): : 67 - 85
  • [9] The ICARUS experiment
    Farnese, Christian
    [J]. 6TH INTERNATIONAL CONFERENCE ON NEW FRONTIERS IN PHYSICS (ICNFP 2017), 2018, 182
  • [10] The upgraded luminosity system for the ZEUS experiment
    Paganis, SD
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2001, 16 : 1147 - 1149