Impact of Weather Conditions on Reliability Indicators of Low-Voltage Cable Lines

被引:1
|
作者
Banasik, Kornelia [1 ]
Chojnacki, Andrzej Lukasz [1 ]
机构
[1] Kielce Univ Technol, Dept Power Engn, PL-25314 Kielce, Poland
来源
ELECTRICITY | 2024年 / 5卷 / 03期
关键词
distribution network; electric power cable lines; power system stability; reliability; failure; weather factors; FAILURES;
D O I
10.3390/electricity5030030
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article examines the impact of meteorological conditions represented by ambient temperature, ambient humidity, wind speed, and daily precipitation sum on the reliability of low-voltage cable lines. Cable line reliability is crucial to the stability and safety of power systems. Failure of cable lines can lead to power outages. This can cause serious economic and social consequences, as well as threaten human safety, especially in the public sector and critical infrastructure. In addition, any interruption of cable lines generates costs related to repairs, operational losses, and possible contractual penalties. This is why it is so important to investigate the causes of power equipment failures. Many power system failures are caused by weather factors. The main purpose of this article is to quantify the actual impact of weather conditions on the performance and reliability of power equipment in distribution networks. Reliability indicators (failure rate, failure duration, restoration rate, and failure coefficient) for low-voltage cable lines were calculated as a function of weather conditions. Empirical values of the indicators were determined based on many years of observations of power lines operating in the Polish power system. An analysis of the conformity of their empirical distribution with the assumed theoretical model was also conducted. By quantifying the impact of specific weather factors on the operation of power equipment, it becomes possible to identify the ranges in which failures are most likely.
引用
收藏
页码:606 / 621
页数:16
相关论文
共 50 条
  • [1] SENSITIVITY OF LOW-VOLTAGE GRID IMPACT INDICATORS TO WEATHER CONDITIONS IN RESIDENTIAL DISTRICT ENERGY MODELING
    Protopapadaki, Christina
    Saelens, Dirk
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 783 - 790
  • [2] Impact of Asymmetry on Energy Loss and Voltage Drops in Low-Voltage Lines
    Gawlak, Anna
    Larisch, Romuald
    PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 84 - 87
  • [3] Influence of wind speed on the reliability of low-voltage overhead power lines
    Banasik, Kornelia
    Chojnacki, Andrzej L.
    Gebczyk, Katarzyna
    Grakowski, Lukasz
    2019 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2019,
  • [4] Comparative analysis of indicators and reliability properties of medium voltage overhead and cable power lines
    Chojnacki, Andrzej L.
    PRZEGLAD ELEKTROTECHNICZNY, 2019, 95 (11): : 26 - 30
  • [5] Analyzing Parameters That Affect the Reliability of Low-Voltage Cable Grids and Their Applicability in Asset Management
    Klerx, Maikel H. P.
    Morren, Johan
    Slootweg, Han
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1432 - 1441
  • [6] Realistic Cable Modeling for Low-Voltage Installations
    Marano, Stefano
    Maret, Yannick
    Varga, Matija
    Ghezzi, Luca
    Butti, Agostino
    2019 16TH INTERNATIONAL CONFERENCE ON SYNTHESIS, MODELING, ANALYSIS AND SIMULATION METHODS AND APPLICATIONS TO CIRCUIT DESIGN (SMACD 2019), 2019, : 177 - 180
  • [8] EARTHING OF LOW-VOLTAGE OVERHEAD LINES
    NERGER, D
    ENERGIETECHNIK, 1979, 29 (05): : 189 - 195
  • [9] New technology for low-voltage power cable sleeve
    Shtrobl, R.
    Graf, R.
    Rasser, S.
    Markelov, I.A.
    Energetik, 2002, (12): : 44 - 46
  • [10] Surge Impact Characteristics of Low-Voltage Overhead Lines Caused by Natural Lightning
    Yan, Xu
    Chen, Shaodong
    Ding, Min
    Chen, Chang
    Zhang, Yijun
    Chen, Lyuwen
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2025,