Outcomes of Micropulse Laser Trabeculoplasty Compared to Selective Laser Trabeculoplasty A Systematic Review and Meta-Analysis

被引:0
|
作者
Zhu, Daniel [1 ,2 ]
Shah, Paras P. [1 ,2 ]
Zhang, Charles [3 ]
Wong, Amanda [4 ]
Bouaziz, Michael [1 ,2 ]
Barmas-Alamdari, Daniel [1 ,2 ]
Mootz, Joseph [1 ,2 ]
Yu, Austin [5 ]
Tirsi, Andrew [1 ,2 ]
Tello, Celso [1 ,2 ]
机构
[1] Northwell Hlth Eye Inst, Dept Ophthalmol, Great Neck, NY 11021 USA
[2] Manhattan Eye Ear & Throat Hosp, New York, NY 10065 USA
[3] Univ Buffalo, State Univ New York, Jacobs Sch Med & Biomed Sci, Ross Eye Inst,Dept Ophthalmol, Buffalo, NY 14203 USA
[4] New York Eye & Ear Infirm, Dept Ophthalmol, New York, NY 10003 USA
[5] Drexel Univ, Coll Med, Dept Ophthalmol, Philadelphia, PA 19129 USA
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
trabeculoplasty; micropulse; SLT; selective laser trabeculoplasty; glaucoma; OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE SPIKES; FLUCTUATIONS; PILOT;
D O I
10.2147/OPTH.S476257
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To perform a meta-analysis and systematic review to compare the efficacy and complications of micropulse laser trabeculoplasty (MLT) and selective laser trabeculoplasty (SLT) in adult patients with open-angle glaucoma (OAG) and ocular hypertension (OHT). Methods: We performed a systematic review utilizing PubMed, Embase, and Scopus, on April 8, 2024. Meta-analyses were performed for the mean change in intraocular pressure (IOP) at one-month, six-month, and one-year follow-up visits, rate of IOP spikes (>5 mmHg increase from the pre-procedure baseline IOP), rate of treatment failure (<20% or <3 mmHg reduction in IOP or requiring additional medications or procedures), and mean change in number of medications. Results: Six studies, with a total of 593 eyes, were included: 283 underwent MLT, while 310 underwent SLT. A statistically significant difference in the efficacy of MLT versus SLT at one-month and six-month follow-ups was present, with SLT reducing IOP by 0.83 mmHg (95% CI: 0.20, 1.47; P = 0.01) more and 0.55 mmHg (95% CI: 0.02, 1.08; P = 0.04) more than MLT, respectively. At the one-year followup, there was no significant disparity in IOP reduction between SLT and MLT (WMD = 0.16; 95% CI: -0.40, 0.71; P = 0.58). There was a significantly lower rate of IOP spikes in the MLT treatment group (RR = 0.37; 95% CI: 0.16, 0.89; P = 0.03). There was no statistically significant difference in the rate of treatment failures (RR = 1.05; 95% CI: 0.68, 1.62; P = 0.84) or number of topical medications reduced (WMD = 0.06; 95% CI: -0.13, 0.26; P = 0.53). Conclusion: While SLT may offer greater short-term reductions in IOP, it may be associated with more postoperative IOP spikes when compared to MLT. At one-year follow-up, there were no significant differences in IOP reduction or failure rates between the MLT and SLT groups.
引用
收藏
页码:2205 / 2215
页数:11
相关论文
共 50 条
  • [1] Outcomes of Micropulse Laser Trabeculoplasty vs. Selective Laser Trabeculoplasty
    Coombs, Peter
    Radcliffe, Nathan M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [2] Comparison of Outcomes of Micropulse Laser Trabeculoplasty versus Selective Laser Trabeculoplasty
    Sun, Catherine Q.
    Ou, Yvonne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Analysis of the Relative Efficacy of Micropulse Laser Trabeculoplasty and Selective Laser Trabeculoplasty
    Gapsis, Briana C.
    Bickford, Matthew
    Sharpe, Robert Allan
    Das, Sudeep
    Kammerdeiner, Leah
    Nutaitis, Matthew J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [4] Comparison of argon laser trabeculoplasty and selective laser trabeculoplasty: a meta-analysis
    Paulo, Audrey
    Razafindrabe, Lalatiana
    Fredette, Marie-Josee
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] Clinical Outcomes of Micropulse Laser Trabeculoplasty Compared to Selective Laser Trabeculoplasty at One Year in Open-Angle Glaucoma
    Sun, Catherine Q.
    Chen, Tiffany A.
    Deiner, Michael S.
    Ou, Yvonne
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 243 - 251
  • [6] Selective Laser Trabeculoplasty versus Argon Laser Trabeculoplasty in Patients with Open-Angle Glaucoma: A Systematic Review and Meta-Analysis
    Wang, Wei
    He, Miao
    Zhou, Minwen
    Zhang, Xiulan
    PLOS ONE, 2013, 8 (12):
  • [7] Selective laser trabeculoplasty vs micropulse laser trabeculoplasty in open-angle glaucoma
    Abramowitz, Benjamin
    Chadha, Nisha
    Kouchouk, Amr
    Alhabshan, Rashed
    Belyea, David A.
    Lamba, Tania
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1599 - 1604
  • [8] Meta-analysis of selective laser trabeculoplasty with argon laser trabeculoplasty in the treatment of open-angle glaucoma
    Wang, Hao
    Cheng, Jin-Wei
    Wei, Rui-Li
    Cai, Ji-Ping
    Li, You
    Ma, Xiao-Ye
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2013, 48 (03): : 186 - 192
  • [9] Comparison of successful outcome predictors for MicroPulse® laser trabeculoplasty and selective laser trabeculoplasty at 6 months
    Hirabayashi, Matthew T.
    Rosenlof, Trevor L.
    An, Jella A.
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1001 - 1009
  • [10] Systematic review and meta-analysis on the efficacy of selective laser trabeculoplasty in open-angle glaucoma
    Wong, Mandy Oi Man
    Lee, Jacky Wai Yip
    Choy, Bonnie Nga Kwan
    Chan, Jonathan Cheuk Hung
    Lai, Jimmy Shiu Ming
    SURVEY OF OPHTHALMOLOGY, 2015, 60 (01) : 36 - 50