A lateral strip assay for ultrasensitive detection of glyphosate in soybeans and corn

被引:0
|
作者
Ma, Xuyang [1 ,2 ,3 ]
Liu, Liqiang [1 ,2 ,3 ]
Song, Shanshan [1 ,2 ,3 ]
Kuang, Hua [1 ,2 ,3 ]
Xu, Chuanlai [1 ,2 ,3 ]
Xu, Xinxin [1 ,2 ,3 ]
机构
[1] Jiangnan Univ, Int Joint Res Lab Biointerface & Biodetect, Wuxi 214122, Jiangsu, Peoples R China
[2] Jiangnan Univ, Sch Food Sci & Technol, Wuxi 214122, Jiangsu, Peoples R China
[3] Jiangnan Univ, State Key Lab Food Sci & Resources, Wuxi, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMATOGRAPHY;
D O I
10.1039/d4an00958d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glyphosate (GLY) is widely applied in agriculture and horticulture as a herbicide. The development of genetically modified plants has caused abuse of GLY, with excessive residues potentially causing harm to human health. Consequently, a novel method needs to be built to detect GLY in soybeans and corn. Computer simulation was used to design an excellent hapten which was used to produce an anti-GLY monoclonal antibody (mAb) with outstanding sensitivity and affinity, and its 50%-inhibitory concentration (IC50) was 128.59 ng mL-1. Afterwards, an immunochromatographic assay strip was developed based on the mAb. In soybeans and corn, the visual detection limits were 1 mg kg-1 and 0.2 mg kg-1, while the cut-off values were 50 mg kg-1 and 5 mg kg-1, respectively. The reliability of the strips was proved by the existing methods. Thus, a rapid method to detect GLY residues on-site in soybeans and corn was established. The determination of glyphosate in soybean (a) and corn (b) samples using a lateral strip assay.
引用
收藏
页码:5232 / 5242
页数:11
相关论文
共 50 条
  • [1] Ultrasensitive immunochromatographic strip assay for the detection of diminazene
    Chao, Mengjia
    Xu, Xinxin
    Liu, Liqiang
    Wu, Aihong
    Song, Shanshan
    Kuang, Hua
    Xu, Chuanlai
    ANALYST, 2021, 146 (15) : 4927 - 4933
  • [2] Aptamer-based lateral flow strip for rapid detection of AFB1 in peanuts, soybeans, corn, and rice
    Wang, Sixian
    Chen, Zhuoer
    Jiang, Shuang
    Zheng, Xiaoling
    Ren, Yueyang
    Nie, Xunqing
    Xiang, Wenyu
    Lei, Xianlu
    Sun, Qi
    Le, Tao
    LWT, 2025, 223
  • [3] Development of an immunochromatographic strip assay for ractopamine detection using an ultrasensitive monoclonal antibody
    Gu, Huaiying
    Liu, Liqiang
    Song, Shanshan
    Kuang, Hua
    Xu, Chuanlai
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2016, 27 (04) : 471 - 483
  • [4] A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples
    Zhang, Guilan
    Zhu, Chao
    Huang, Yafei
    Yan, Jiao
    Chen, Ailiang
    MOLECULES, 2018, 23 (02):
  • [5] Multifunctional nanoenzyme lateral flow immunoassay strip for rapid and ultrasensitive detection of carbofuran in vegetables
    Zhai, Shengxi
    Dong, Haowei
    Wang, Haifang
    Huang, Jingcheng
    Li, Donghan
    Li, Zhengtao
    Li, Zhaopeng
    Li, Peisen
    Zhang, Pengwei
    Zhao, Mingxin
    Sun, Xia
    Guo, Yemin
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 477
  • [6] Rapid on-site detection of imazaquin residue in corn and soybeans using an immunochromatographic assay
    Ma, Xuyang
    Guo, Lingling
    Liu, Liqiang
    Kuang, Hua
    Xu, Chuanlai
    Qu, Aihua
    JOURNAL OF MATERIALS CHEMISTRY B, 2025, 13 (08) : 2695 - 2704
  • [7] Nanoparticles-based lateral flow strip for halofuginone ultrasensitive detection in chicken and beef
    Ma, Xuyang
    Feng, Yongwei
    Yang, Ting
    Xu, Liguang
    Kuang, Hua
    Xu, Chuanlai
    Guo, Lingling
    FOOD BIOSCIENCE, 2024, 59
  • [8] Ultrasensitive immunochromatographic strip for detection of cyproheptadine
    Guo, Mengyuan
    Sun, Li
    Liu, Liqiang
    Song, Shanshan
    Kuang, Hua
    Cui, Gang
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2018, 29 (01) : 941 - 952
  • [9] Universal and ultrasensitive detection of foodborne bacteria on a lateral flow assay strip by using wheat germ agglutinin-modified magnetic SERS nanotags
    Tu, Zhijie
    Cheng, Siyun
    Dong, Hao
    Wang, Wenqi
    Yang, Xingsheng
    Gu, Bing
    Wang, Shengqi
    Wang, Chongwen
    RSC ADVANCES, 2022, 12 (42) : 27344 - 27354
  • [10] Simultaneous and ultrasensitive detection of three pesticides using a surface-enhanced Raman scattering-based lateral flow assay test strip
    Sheng, Enze
    Lu, Yuxiao
    Xiao, Yue
    Li, Zhenxi
    Wang, Huaisheng
    Dai, Zhihui
    BIOSENSORS & BIOELECTRONICS, 2021, 181