Determining of the thermo-hydraulic characteristics and exergy analysis of a triple helical tube with inner twisted tube

被引:2
|
作者
Abdelmagied, Mahmoud [1 ]
机构
[1] Helwan Univ, Fac Technol & Educ, Refrigerat & AC Technol Dept, Helwan 11282, Egypt
关键词
Triple tube; Helical coil; annulus space; Twisted tube; CFD; HEAT-TRANSFER COEFFICIENTS; CORRUGATED TUBES; EXCHANGER; PERFORMANCE; FLOW; NANOFLUIDS;
D O I
10.1016/j.cep.2024.109922
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An innovative technique to enhance heat transfer as a passive method was investigated. The combination of the twisted tube and helical coil to increase the swirl intensity is presented. The current investigation showed experimentally and numerically the exergy and thermal performance analysis of a new design of a triple tube design called a triple helical tube with inner twisted tube, THTITT. The new design is a modified design of a double helical tube with inner twisted tube, DHTITT which is created by twisting the inner tube. Besides the benefits of adding the third fluid to DHTITT that achieve extra contact surface area per unit length between the intermediate tube and the new passage in the outer tube. In which expected to enhance the temperature gradient between the three fluids and consequently, the thermal characteristics augment occurred. The twisted tube increased the intensity of the swirl flow and more intense disturbance of the fluid in the tube occurred. A 3d CFD model was established to get more insight at a level of detail not always available in the experiment. The effects of twisted pitch ratio, hydraulic diameter, w , helical coil torsion, a , helical coil inclination angle, qp , as well as Dean number, N Dn, h were explored. Four groups of test specimens include various of 5.32, 7.97, and infinity, various w of 3.8, 6.8, and 9.9 mm, various alpha of 0.068, 0.095, and 0.121, and various qp of 0 degrees, degrees , 45 degrees, degrees , and 90 degrees degrees were established, manufactured and examined in this investigation. The investigation covered Reynolds number, N Re,h , for a range of 2450:29300 corresponding to Dean number, N Dn, h , for a range of 570:4800. The results showed a higher Nusselt number, N Nu, h , of THTITT compared to DHTITT by 61.8 %%, while the increase in fh h is approximately negligible. Also, by decreasing from infinity to 5.32 increases N Nu, h by 33.4 %, with an increase in friction factor, fh h by 57.6 %. Furthermore, with a decreasing w from 9.9 mm to 3.8 mm, a significant increase in N Nu, h occurs by 20.6 %, at the expense of increasing fh h by 36.4 %. In addition, with decreasing a from 0.121 to 0.068, a significant increase in N Nu, h occurs by 27.6 %, at the expense of increasing fh h by 17.1 %. Finally, the THTITT decreases the heat loss (exergy destruction) between the hot and cold fluids. New correlations to predict N Nu,h , and fh h are presented.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Thermo-hydraulic and exergy characteristics of a triple tube helical coil with inner triangular twisted tube
    Abdelmagied, Mahmoud
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2024, 32 (01)
  • [2] Thermo-fluid characteristics and exergy analysis of a twisted tube helical coil
    Abdelmagied, Mahmoud
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] Effect of ultrasonic on thermo-hydraulic characteristics of shell and tube heat exchangers with twisted tape
    Wang, Wenqing
    Yu, Chulin
    Lv, Xiaohan
    Yang, Yvxi
    Zhang, Haiqing
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [4] Effects of twisted tape structures on thermo-hydraulic performances of nanofluids in a triangular tube
    Qi, Cong
    Liu, Maoni
    Luo, Tao
    Pan, Yuhang
    Rao, Zhonghao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 146 - 159
  • [5] Thermo-Hydraulic Performance Analysis on the Effects of Truncated Twisted Tape Inserts in a Tube Heat Exchanger
    Ghalambaz, Mehdi
    Mashayekhi, Ramin
    Arasteh, Hossein
    Ali, Hafiz Muhammad
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    SYMMETRY-BASEL, 2020, 12 (10): : 1 - 22
  • [6] Numerical Study on Thermo-Hydraulic Performance of Enhanced Tube With Crossed Helical Dimples
    Zheng, Jiyu
    Liang, Zheng
    Zhang, Liang
    Qiu, Yangjun
    Zhou, Jiawei
    Yan, Zhongchao
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2023, 15 (11)
  • [7] Thermo-hydraulic analysis for a novel eccentric helical screw tape insert in a three dimensional tube
    Zade, Navid Moghadas
    Akar, Shima
    Rashidi, Saman
    Esfahani, Javad Abolfazli
    APPLIED THERMAL ENGINEERING, 2017, 124 : 413 - 421
  • [8] Numerical study on thermo-hydraulic characteristics of turbulent flow in a circular tube fitted with helical blade rotors
    Zhang, Zhen
    Yang, Weimin
    Guan, Changfeng
    Ding, Yumei
    Yan, Hua
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 60 : 603 - 611
  • [9] Thermo-hydraulic analysis and optimization of finned tube heat exchangers
    Alavi, Sayed Ehsan
    Shirbani, Meisam Moory
    MULTISCALE AND MULTIDISCIPLINARY MODELING EXPERIMENTS AND DESIGN, 2024, 7 (03) : 2031 - 2043
  • [10] Study of thermo-hydraulic performance in a circular tube with elliptical protruded twisted tape inserts
    Venkataramaiah, Harish Hassan
    Nagaraja, Santhosh
    Raikar, Prasad
    Raja, Vijayanandh
    Hussain, Fayaz
    Asif, Mohammad
    Atamurotov, Farruh
    Benti, Natei Ermias
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,