Roles of Interdigitated Electrode Geometry in Non-Faradaic Impedimetric Biosensors

被引:1
|
作者
Assaifan, Abdulaziz K. [1 ]
Almansour, Rawan A. [1 ]
Alessa, Jana A. [1 ]
Alhudaithy, Soliman [1 ]
Fakhouri, Abdulaziz S. [1 ]
Alsaleh, Ahmad A. [2 ]
机构
[1] King Saud Univ, Coll Appl Med Sci, Dept Biomed Technol, Riyadh 11451, Saudi Arabia
[2] King Saud Univ, Coll Sci, Chem Dept, Riyadh 11451, Saudi Arabia
关键词
non-faradaic; electrochemical impedance spectroscopy; interdigitated electrodes; geometry; biosensor; THIN-FILMS; IMPEDANCE; SURFACE;
D O I
10.1149/1945-7111/ad6a99
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work, we investigate the effect of interdigitated electrode fingers width and gap on the performance of biosensors. Two different configurations of interdigitated electrodes were utilized; one consists of 50 mu m wide fingers with a gap of 50 mu m, and the other consists of 100 mu m wide fingers with a 100 mu m gap. First, the active surface area of both interdigitated electrodes was investigated. Then, the surface electronic parameters were investigated using faradaic and non-faradaic electrochemical impedance spectroscopy modes. Both interdigitated electrodes were then functionalized with LDL-antibodies through a standard chemical functionalization route and were utilized for the detection of LDL-antigen of cholesterol. The biosensor with 50 mu m width and gap demonstrated better sensitivity and limit of detection of 6.08 nF/log(ng/ml) and 40 pg ml-1, respectively. Biosensors with 100 mu m finger width and gap sensitivity and detection limit are 5.16 nF/log(ng/ml) and 300 pg ml-1, respectively. The enhanced sensitivity and limit of detection for the first biosensor is due to the increased surface area, enhanced electric field, and less diffusion of ions onto the biosensor surface. The study reported here suggests room for improving the geometry of many interdigitated electrodes for enhanced non-faradaic biosensing performances.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effect of Applied AC Voltage on the Performance of Non-Faradaic Impedimetric Biosensors
    Alzahrani, Khalid E.
    Almansour, Meshael J.
    Qurayshan, Shahad M.
    Albrithen, Hamad
    Fakhouri, Abdulaziz S.
    Alhussaini, Khalid
    Assaifan, Abdulaziz K.
    Alodhayb, Abdullah N.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (03)
  • [2] Probing the Influence of Crosslinking Layer Incubation Time on the Performance of Non-Faradaic Impedimetric Biosensors
    Assaifan, Abdulaziz K.
    Aljdidalmri, Abdulrahman S.
    Albrithen, Hamad
    Alodhayb, Abdullah
    Alzahrani, Khalid E.
    Alshammari, Abeer
    Al-Gawati, Mahmoud A.
    Aldeligan, Saleh Husam
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (11)
  • [3] Faradaic and non-faradaic depletions by anodic electrode corrosion with strong electrolytes on tautochrone curve interdigitated electrodes
    Lim, Jia-Chun
    Gopinath, Subash C. B.
    Krishnan, Hemavathi
    Tan, Sing-Mei
    MATERIALS CHEMISTRY AND PHYSICS, 2025, 331
  • [4] Design of a High Sensitive Non-Faradaic Impedimetric Sensor
    Selvam, Anjan Panneer
    Vattipalli, Krishna M.
    Prasad, Shalini
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3251 - 3254
  • [5] INFLUENCE OF NATURE OF ELECTRODE ON NON-FARADAIC ELECTROLYSIS
    PALIT, SR
    GHOSH, S
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1976, 53 (11) : 1099 - 1103
  • [6] Electrochemical impedimetric biosensors, featuring the use of Room Temperature Ionic Liquids (RTILs): Special focus on non-faradaic sensing
    Upasham, Sayali
    Banga, Ivneet Kaur
    Jagannath, Badrinath
    Paul, Anirban
    Lin, Kai-Chun
    Muthukumar, Sriram
    Prasad, Shalini
    BIOSENSORS & BIOELECTRONICS, 2021, 177
  • [7] LAPLACE PLANE ANALYSIS OF FARADAIC AND NON-FARADAIC IMPEDANCE OF MERCURY-ELECTRODE
    DOBLHOFER, K
    PILLA, AA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1972, 39 (01) : 91 - +
  • [8] Hybridization-induced interfacial changes detected by non-Faradaic impedimetric measurements compared to Faradaic approach
    Gautier, Christelle
    Esnault, Charles
    Cougnon, Charles
    Pilard, Jean-Francois
    Casse, Nathalie
    Chenais, Benoit
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 610 (02) : 227 - 233
  • [9] Comparison of Faradaic and Non-Faradaic Impedance Biosensors Using 2-Electrode and 3-Electrode Configurations for the Determination of Bovine Serum Albumin (BSA)
    Nhu, Chi Tran
    Quoc, Tuan Vu
    Quang, Loc Do
    Dang, Phu Nguyen
    Chun-Ping, Jen
    Duc, Trinh Chu
    Thanh, Tung Bui
    ANALYTICAL LETTERS, 2024, 57 (17) : 2959 - 2971
  • [10] RECENT TRENDS IN NON-FARADAIC SUPERCAPACITOR ELECTRODE MATERIALS
    Okwundu, Onyeka Stanislaus
    Ugwuoke, Cyril Oluchukwu
    Okaro, Augustine Chukwujekwu
    METALLURGICAL & MATERIALS ENGINEERING, 2019, 25 (02) : 105 - 138