Onsite Partial Discharge Detection and Location System for Underground Cables Using USRP-Based Measurement System

被引:0
|
作者
Atseverl, Mert Bekir [1 ]
Boyaci, Ali [2 ]
Yarkan, Serhan [3 ]
Hocaoglu, Mehmet Hakan [2 ]
机构
[1] Gebze Tech Univ, Dept Elect Engn, Kocaeli, Turkiye
[2] Istanbul Ticaret Univ, Dept Elect Engn, Istanbul, Turkiye
[3] Istanbul Ticaret Univ, Ctr Appl Res Informat Technol CARIT, Istanbul, Turkiye
关键词
partial discharge; cable; USRP; location; onsite application;
D O I
10.1109/GPECOM61896.2024.10582615
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The accuracy of PD location is particularly crucial for mission-critical cable feeders. Highly accurate PD position estimation increases efficiency by reducing repair costs and time spent on operation. Commercial PD measurement devices generally have high costs and maintenance fees. This study proposes an easily connected, portable USRP-based PD measurement system. The effectiveness of the proposed measurement system is demonstrated by simultaneous on-site measurements with a commercial PD measurement device. The PD position obtained by the proposed method is compatible with the results obtained with the commercial PD measurement device.
引用
收藏
页码:368 / 373
页数:6
相关论文
共 50 条
  • [1] On-line partial discharge monitoring system for underground MV cables - Part II: Detection and location
    Milioudis, Apostolos
    Andreou, Georgios
    Labridis, Dimitris
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 109 : 395 - 402
  • [2] A centralized condition monitoring system for MV power cables based on on-line partial discharge detection and location
    van der Wielen, Peter C. J. M.
    Steennis, E. Fred
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1166 - 1170
  • [3] Field location of partial discharge in power cables using an adaptive noise mitigating system
    Hariri, A
    Du, ZF
    Sui, D
    Mashikian, MS
    Jordan, D
    [J]. CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 121 - 125
  • [4] USRP-Based Frequency Hopping Signal Record and Playback System
    Tong, Li
    Wang, Shaoxuan
    Tang, Xinqiang
    Wei, Xun
    Lin, Lidong
    [J]. PROCEEDINGS OF 2016 SIXTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2016), 2016, : 389 - 393
  • [5] A USRP-Based GNSS and Interference Signal Generator and Playback System
    Di, Ruihui
    Peng, Senlin
    Taylor, Steve
    Morton, Yu
    [J]. 2012 IEEE/ION POSITION LOCATION AND NAVIGATION SYMPOSIUM (PLANS), 2012, : 470 - 478
  • [6] Improved Exit Path Identification with Indoor USRP-based Radar System
    Liu, Yunxiang
    Guan, Yong Liang
    Garmatyuk, Dmitriy
    Quitin, Francois
    [J]. PROCEEDINGS OF THE ION 2015 PACIFIC PNT MEETING, 2015, : 355 - 364
  • [7] Automatic measurement system for partial discharge detection
    Carminati, Edoardo
    [J]. Energia Elettrica, 1988, 65 (09): : 385 - 391
  • [8] EXAMINATION AND LOCATION OF PARTIAL DISCHARGE SITES IN SEVERELY AGED UNDERGROUND DISTRIBUTION CABLES
    MCBRIDE, JE
    HARPER, VS
    COFFEEN, LT
    STANLEY, FT
    NG, HW
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) : 629 - 638
  • [9] Online Partial Discharge Detection and Location System Using Wireless Sensor Network
    He, Xin
    Xie, Guangzhong
    Jiang, Yadong
    [J]. PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011), 2011, 12
  • [10] Partial Discharge Measurement of EHV Underline Transmission XLPE Cables using FSA System Application
    Shin, D-H
    Lim, K-J
    Lwin, K-S
    Lee, Y-S
    Yang, J-S
    Park, N-J
    Park, D-H
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 569 - +