Reactive Gas Cluster Ion Beams for Enhanced Drug Analysis by Secondary Ion Mass Spectrometry

被引:0
|
作者
Lagator, Matija [1 ,2 ]
Patel, Bilal [1 ]
Sheraz, Sadia [1 ]
Lockyer, Nicholas [1 ]
机构
[1] Univ Manchester, Photon Sci Inst, Dept Chem, Oxford Rd, Manchester M13 9PL, England
[2] Rosalind Franklin Inst, Didcot OX11 0QX, Oxon, England
基金
英国工程与自然科学研究理事会;
关键词
TOF-SIMS; IONIZATION PROBABILITY; SURFACE-ANALYSIS; TIME; SILVER; BOMBARDMENT; PROJECTILE; EFFICIENCY; YIELDS; ARGON;
D O I
10.1021/acs.analchem.4c02144
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we investigate the formation and composition of Gas Cluster Ion Beams (GCIBs) and their application in Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) analysis. We focus on altering the carrier gas composition, leading to the formation of (Ar/CO2)(n) or (H2O)(n) GCIBs. Our results demonstrate that the addition of a reactive species (CO2) to water GCIBs significantly enhances the secondary ion yield of small pharmaceutical compounds in the positive ion mode. In negative ion mode, the addition of CO2 resulted in either a positive enhancement or no effect, depending on the sample. However, an excess of CO2 in the carrier gas leads to the formation of carbon dioxide clusters, resulting in reduced yields compared to that of water cluster beams. Cluster size also plays a crucial role in overall yields. In a simple two-drug system, CO2-doped water clusters prove effective in mitigating matrix effects in positive ion mode compared to pure water cluster, while in negative ion mode, this effect is limited. These clusters are also applied to the analysis of drugs in a biological matrix, leading to more quantitative measurements as shown by a better fitting calibration curve. Overall, the doping of water clusters with small amounts of a reactive gas demonstrates promising benefits for higher sensitivity, higher resolution molecular analysis, and imaging using ToF-SIMS. The effectiveness of these reactive cluster beams varies depending on the experimental parameters and sample type.
引用
收藏
页码:15185 / 15193
页数:9
相关论文
共 50 条
  • [1] Gas Cluster Ion Beams for Secondary Ion Mass Spectrometry
    Winograd, Nicholas
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 11, 2018, 11 : 29 - 48
  • [2] Secondary ion mass spectrometry with gas cluster ion beams
    Toyoda, N
    Matsuo, J
    Aoki, T
    Yamada, I
    Fenner, DB
    APPLIED SURFACE SCIENCE, 2003, 203 : 214 - 218
  • [3] Secondary ion mass spectrometry with gas cluster ion beams
    Toyoda, N
    Matsuo, J
    Aoki, T
    Yamada, I
    Fenner, DB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 190 : 860 - 864
  • [4] Sensitivity enhancement using chemically reactive gas cluster ion beams in secondary ion mass spectrometry (SIMS)
    Lagator, Matija
    Razo, Irma Berrueta
    Royle, Thomas
    Lockyer, Nicholas P.
    SURFACE AND INTERFACE ANALYSIS, 2022, 54 (04) : 349 - 355
  • [5] Secondary ion mass spectrometry using cluster primary ion beams
    Gillen, G
    Fahey, A
    APPLIED SURFACE SCIENCE, 2003, 203 : 209 - 213
  • [6] Enhanced Ion Yields Using High Energy Water Cluster Beams for Secondary Ion Mass Spectrometry Analysis and Imaging
    Sheraz, Sadia
    Tian, Hua
    Vickerman, John C.
    Blenkinsopp, Paul
    Winograd, Nicholas
    Cumpson, Peter
    ANALYTICAL CHEMISTRY, 2019, 91 (14) : 9058 - 9068
  • [7] Secondary ion mass spectrometry using polyatomic and cluster primary ion beams
    Gillen, G
    MICROBEAM ANALYSIS 2000, PROCEEDINGS, 2000, (165): : 339 - 340
  • [8] Dynamic Reactive Ionization with Cluster Secondary Ion Mass Spectrometry
    Tian, Hua
    Wucher, Andreas
    Winograd, Nicholas
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (02) : 285 - 292
  • [9] Quantitative analysis of lipids with argon gas cluster ion beam secondary ion mass spectrometry
    Fujii, Makiko
    Nakagawa, Shunichirou
    Seki, Toshio
    Aoki, Takaaki
    Matsuo, Jiro
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (12-13) : 1129 - 1132
  • [10] Negative cesium sputter ion source for generating cluster primary ion beams for secondary ion mass spectrometry analysis
    Gillen, G
    King, L
    Freibaum, B
    Lareau, R
    Bennett, J
    Chmara, F
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2001, 19 (02): : 568 - 575