Sciatic nerve fascicle differentiation on high-resolution ultrasound with histological verification: An ex vivo study

被引:7
|
作者
Snoj, Ziga [1 ,2 ]
Pusnik, Luka [3 ]
Cvetko, Erika [3 ]
Maticic, Ursa Burica [1 ]
Jengojan, Suren Armeni [4 ]
Omejec, Gregor [5 ,6 ]
机构
[1] Univ Med Ctr Ljubljana, Radiol Inst, Zaloska 7, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
[3] Univ Ljubljana, Inst Anat, Fac Med, Ljubljana, Slovenia
[4] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Vienna, Austria
[5] Univ Med Ctr Ljubljana, Inst Clin Neurophysiol, Div Neurol, Ljubljana, Slovenia
[6] Higher Educ Inst Fizioterapevtika, Ljubljana, Slovenia
关键词
high-resolution ultrasonography; histological cross-sections; nerve fascicle; nerve microanatomy; sciatic nerve; PERIPHERAL-NERVES; HIGH-FREQUENCY; REFERENCE VALUES; SONOGRAPHY; POLYNEUROPATHY; MICROSCOPY; VOLUME; US;
D O I
10.1002/mus.28181
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction/Aims The development of high-resolution ultrasound (HRUS) has enabled the depiction of peripheral nerve microanatomy in vivo. This study compared HRUS fascicle differentiation to the structural depiction in histological cross-sections (HCS). Methods A human cadaveric sciatic nerve was marked with 10 surgical sutures, and HRUS image acquisition was performed with a 22-MHz probe. The nerve was excised and cut into five segments for HCS preparation. Selected HCS were cross-referenced to HRUS, with sutures to improve orientation. Sciatic nerve and fascicle contouring were performed to assess nerve and fascicular cross-sectional area (CSA), fascicle count, and interfascicular distances. Three groups were defined based on HRUS fascicle differentiation in comparison to HCS, namely single fascicle (SF), fascicular cluster (FC), and no depiction (ND) group. Results On cross-referenced HRUS to HCS images, 58% of fascicles were differentiated. On HRUS, significantly larger fascicle CSA and smaller fascicle count were observed compared with HCS. Group analysis showed that 41% of fascicles were defined as SF, 47% as FC, and 12% as ND. The mean fascicle CSA in the ND group was 0.05 mm(2). Compared with the SF, the FC had significantly larger fascicle CSA (1.2 +/- 0.7 vs. 0.6 +/- 0.4 mm(2); p < .001) and shorter interfascicular distances (0.1 +/- 0.04 vs. 0.5 +/- 0.3 mu m; p < .001). Discussion While HRUS can depict fascicular anatomy, only half of the fascicles visualized on HRUS directly correspond to single fascicles observed on HCS. The amount of interfascicular epineurium appears to influence the ability of HRUS to differentiate individual fascicles.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 50 条
  • [1] Fascicle differentiation of upper extremity nerves on high-resolution ultrasound with multimodal microscopic verification
    Pusnik, Luka
    Radochova, Barbora
    Janacek, Jiri
    Saudek, Frantisek
    Sersa, Igor
    Cvetko, Erika
    Umek, Nejc
    Snoj, Ziga
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [2] Median and ulnar nerve fascicle imaging using MR microscopy and high-resolution ultrasound
    Ziga, Snoj
    Igor, Sersa
    Ursa, Maticic
    Plut, Domen
    Erika, Cvetko
    Gregor, Omejec
    JOURNAL OF NEUROIMAGING, 2022, 32 (03) : 420 - 429
  • [3] High-resolution photoacoustic/ultrasound imaging of the porcine stomach wall: an ex vivo feasibility study
    Kim, Jaewoo
    Ahn, Joongho
    Kang, Gwansuk
    Ha Hwang, Joo
    Kim, Chulhong
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (11) : 6717 - 6729
  • [4] Correlation between age and the sciatic nerve diameter in the first 2 years of life: A high-resolution ultrasound study
    Jenny, Carole
    van der Linde, Jacoba
    Hundsberger, Thomas
    Broser, Philip J.
    BRAIN AND BEHAVIOR, 2023, 13 (04):
  • [5] High-resolution ultrasound of radial nerve
    Martinoli, C
    Bianchi, S
    Pugliese, F
    Ruaro, L
    Crespi, G
    Derchi, LE
    RADIOLOGY, 2002, 225 : 605 - 605
  • [6] Medical Image Analysis of Rat Sciatic Nerve Anatomy Based on High-Resolution Ultrasound Imaging
    Huang, Yunxia
    Hu, Bing
    Zhu, Jiaan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (04) : 815 - 819
  • [7] QUANTITATIVE ASSESSMENT OF GINGIVAL INFLAMMATION USING HIGH-RESOLUTION ULTRASOUND EX-VIVO
    Sayed, Ahmed M.
    Lamarck, Rachel
    Cruz, Elisa
    Chaves, Eros
    Mukdadi, Osama M.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2018, 18 (03)
  • [8] Assessing Mitochondrial Function in Sciatic Nerve by High-Resolution Respirometry
    Formiga-Jr, Marcos A.
    Camacho-Pereira, Juliana
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (183):
  • [9] High-resolution Ultrasound of Peripheral Nerve Disorders
    Le Corroller, Thomas
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2024, 28 (06) : 708 - 717
  • [10] Peripheral nerve high-resolution ultrasound in diabetes
    Breiner, Ari
    Qrimli, Mohammad
    Ebadi, Hamid
    Alabdali, Majed
    Lovblom, Leif E.
    Abraham, Alon
    Albulahi, Hana
    Perkins, Bruce A.
    Bril, Vera
    MUSCLE & NERVE, 2017, 55 (02) : 171 - 178