Comparative Study of the Normalized-Error-Based Control and Traditional Current-Mode Control for a Sixth-Order Boost Converter

被引:0
|
作者
Mishra, Avinash [1 ]
Mandal, Sanjoy [1 ]
Tatini, Narendra Babu [2 ]
Gunnam, Leenendra Chowdary [3 ]
Chincholkar, Satyajit Hemant [4 ]
机构
[1] Indian Inst Technol ISM Dhanbad, Dept Elect Engn, Dhanbad 826004, Jharkhand, India
[2] Koneru Lakshmaiah Educ Fdn, Dept Internet Things, Guntur 522302, Andhra Pradesh, India
[3] SRM Univ AP, Dept Elect & Commun Engn, Amaravati 522240, Andhra Pradesh, India
[4] MIT Acad Engn, Sch E&TC Engn, Dept Elect & Telecommun Engn, Pune 412105, India
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Topology; Stability analysis; Voltage control; Renewable energy sources; DC-DC power converters; Transient response; Inductors; High-order boost converter; current-mode control; normalized-error; DC-DC CONVERTER;
D O I
10.1109/ACCESS.2024.3431614
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Current-mode control is a commonly utilized control strategy for the step-up power converters because these converters' control-to-output transfer function contains right-half plane zeros. The main concern associated with the recent dual-loop current-mode controller (CMC) is that the integrator operates on the error term itself. Thus, integrand can assume extremely large values when error is large such as during transient response, and the controller output may saturate, especially when sufficiently large controller gains are used. If lower gain values of gains are used, the speed of response in the presence of small parameter variations could be much lower. Thus, there is a compromise between the transient response when error signal is large and speed of the response for small error signals. To address these concerns, an improved normalized-error based current-mode controller (NECC) is employed for voltage regulation in a sixth-order boost configuration. This controller's main characteristic is that the integrator now operates on a bounded integrand which is a normalized-error. This avoids the integrator saturation and also increase the room for tuning the controller gains. The state-space averaged model of the topology is given and a detailed stability analysis is shown. The main contribution of the paper is that a detailed comparative study of the traditional CMC and an improved NECC based on some simulation and experimental waveforms is provided. Both simulation and experimental outcomes clearly prove the superiority of the proposed NECC in terms of an improved speed and less overshoot of the output voltage response.
引用
下载
收藏
页码:102178 / 102187
页数:10
相关论文
共 50 条
  • [1] Chaos Control for the Boost Converter under Current-mode Control
    He, Lihong
    Jia, Meimei
    Dong, Zhongwen
    Wu, Jianhua
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 3579 - 3583
  • [2] Microcontroller implementation of current-mode control for a discontinuous mode boost converter
    He, D
    Dillard, W
    Nelms, RM
    2002 37TH INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE (IECEC), 2002, : 255 - 260
  • [3] Current-mode control for a quadratic boost converter with a single switche
    Ortiz-Lopez, M. G.
    Leyva-Ramos, J.
    Diaz-Saldiema, L. H.
    Garcia-Ibarra, J. M.
    Carbajal-Gutierrez, E. E.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 2652 - 2657
  • [4] Control bifurcation in PFC Boost converter under peak current-mode control
    Ke, Yi-Jing
    Zhou, Yu-Fei
    Chen, Jun-Ning
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1392 - +
  • [5] Inductor Current Sampled Feedback Control of Chaos in Current-Mode Boost Converter
    Bo-Cheng Bao and Yan Liang
    Journal of Electronic Science and Technology, 2008, (01) : 52 - 55
  • [6] Charge-pump Based Sixth-order Interleaved Boost Converter
    Veerachary, Mummadi
    Prakash, Jyoti
    2017 4TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ELECTRONICS (UPCON), 2017, : 351 - 357
  • [7] Comparative study of current-mode controllers for a high-order boost dc-dc converter
    Chan, Chok You
    IET POWER ELECTRONICS, 2014, 7 (01) : 237 - 243
  • [8] Implementation of fuzzy logic controller with bifurcation control of a current-mode boost converter
    Khaehintung, Noppadol
    Sirisuk, Phaophak
    Kunakorn, Anantawat
    2007 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1-4, 2007, : 1429 - +
  • [9] Chaotic Behavior of the Buck-Boost Converter under Current-Mode Control
    Negoitescu, Dan
    Lascu, Dan
    Popescu, Viorel
    Ivan, Corina
    PROCEEDINGS OF THE 12TH WSEAS INTERNATIONAL CONFERENCE ON CIRCUITS: NEW ASPECTS OF CIRCUITS, 2008, : 125 - +
  • [10] Monolithic DC-DC Boost Converter with Current-Mode Hysteretic Control
    Hasan, Ayaz
    Gregori, Stefano
    Ahmed, Imran
    Chik, Raymond
    2011 24TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2011, : 1242 - 1245