A novel contingency screening and ranking index for grid-forming converter-based sources following generator outage

被引:0
|
作者
Yogarathnam, Amirthagunaraj [1 ]
Karunaratne, Lilan [2 ]
Chaudhuri, Nilanjan Ray [2 ]
Yue, Meng [1 ]
机构
[1] Brookhaven Natl Lab, Interdisciplinary Sci Dept, Upton, NY 11973 USA
[2] Penn State Univ, Sch Elect Engn & Comp Sci, University Pk, PA 16802 USA
关键词
DC-link voltage collapse; DC-side current limit; Dynamic security assessment; Generator outage; Grid-forming converter; Online contingency screening and ranking; Power tracing algorithm; POWER; INVERTERS; STABILITY; SYSTEM;
D O I
10.1016/j.ijepes.2024.110141
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the current trend, the power generation in the future power grids is expected to consist of a large number of converter-interfaced generations (CIGs) with a small percentage of synchronous generators (SGs) producing power from hydro, solar thermal, or even nuclear resources. These notable changes pose significant challenges to the secure operation of the power grid. One such issue is new cascading failure mechanisms introduced by CIGs, especially due to the dc-link voltage collapse in a dc-current limited grid-forming converter (GFC) following a generation outage. Therefore, in the online dynamic security assessment (DSA), the system operators would be interested in knowing the critical outages that may trigger this cascading mechanism in the system. To address this issue, this paper presents a contingency screening and ranking approach (which can be a part of a DSA) for generator outages in a modern grid that consists of SGs and GFCs. Our specific focus is to identify the critical outages that may lead to a cascading failure in the system due to a dc-voltage collapse in the GFCs. To that end, first, a novel contingency screening and ranking index for an (N-1) contingency scenario (i.e., outage of a single generator) is derived based on the traditional generator power tracing algorithm. Then, it is shown that the proposed ranking index can be extended to any (N-k) contingency scenarios. Finally, the effectiveness of the proposed approach following generator outages (up to (N-2) contingencies) is demonstrated using detailed time-domain simulations in two different modified test configurations of a 16-machine 68-bus New York-New England test system with GFCs using the MATLAB/Simulink platform.
引用
收藏
页数:13
相关论文
共 13 条
  • [1] Stability enhancement strategies for a 100% grid-forming and grid-following converter-based Irish power system
    Zhao, Xianxian
    Flynn, Damian
    IET RENEWABLE POWER GENERATION, 2022, 16 (01) : 125 - 138
  • [2] Grid-forming requirements based on stability assessment for 100% converter-based Irish power system
    Zhao, Xianxian
    Thakurta, Priyanko Guha
    Flynn, Damian
    IET RENEWABLE POWER GENERATION, 2022, 16 (03) : 447 - 458
  • [3] Enhanced Transient Angle Stability Control of Grid-Forming Converter Based on Virtual Synchronous Generator
    Chen, Meng
    Zhou, Dao
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (09) : 9133 - 9144
  • [4] Small signal analysis of a grid-forming modular multilevel converter with a novel virtual synchronous generator control
    Jiang, Chen
    Sinkar, Ajinkya D.
    Gole, Aniruddha M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223
  • [5] A novel Koopman-inspired method for the secondary control of microgrids with grid-forming and grid-following sources
    Gong, Xun
    Wang, Xiaozhe
    APPLIED ENERGY, 2023, 333
  • [6] 100 % Converter-based Distribution Grids: Determining The Required Grid-forming Penetration to Ensure Small-Signal Stability
    Kircheis, Jan
    Kayser, Johannes
    Schlegel, Steffen
    Westermann, Dirk
    2023 IEEE BELGRADE POWERTECH, 2023,
  • [7] Analysis of broadband oscillation mechanisms in grid-forming and grid-following converters based on virtual synchronous generator
    Wang, Weiming
    Liu, Zhijian
    Lou, Jun
    Cheng, Cheng
    Song, Qi
    Shi, Yaoting
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2025, 19 (01)
  • [8] An novel oscillation suppression strategy for permanent magnetic synchronous generator based on grid-forming control
    Ren, Bixing
    Li, Qiang
    Zou, Xiaoming
    Wang, Chenggen
    Jia, Yongyong
    Energy Reports, 2024, 11 : 3163 - 3170
  • [9] An novel oscillation suppression strategy for permanent magnetic synchronous generator based on grid-forming control
    Ren, Bixing
    Li, Qiang
    Zou, Xiaoming
    Wang, Chenggen
    Jia, Yongyong
    ENERGY REPORTS, 2024, 11 : 3163 - 3170
  • [10] Mechanism and Characteristics of Grid-forming Control for Improving Sub/Super Synchronous Oscillation Stability of Grid-following-based Grid-connected Converter
    Liu P.
    Xie X.
    Li Y.
    Yi S.
    Su P.
    Dai X.
    Ma N.
    Dianwang Jishu/Power System Technology, 2024, 48 (03): : 990 - 997